background image

6

Rheem Manufacturing Company

ACCESSORIES—DOWNFLOW

DOWNFLOW WARNING: Unit design is certified for installation on non-com-
bustible floor. A special factory supplied combustible floor sub-base is
required when installing on a combustible floor. Failure to install the sub-base
may result in fire, property damage and personal injury.

RXPF-F01 and F02

FOSSIL FUEL KITS

—are for use

with Rheem Heat Pumps and
Criterion II warm air furnaces. The
RXPF-F02 meets TVA requirements.

RXGF-CC*

FILTER RACK

—Downflow top

return mount.

NOTE: 

Filter racks are shipped
without filters.

*Filters available through

PROSTOCK ™.

OPTION CODE FOR HIGH
ALTITUDE: 

US-277
Canada-298

(Kit packaged with furnace.
Requires field installation.)

PLENUM DATA—“A” COILS

Plenum adapters are required in some instances for use on downflow applications
when plenum and furnace size do not match.

NOTE: See Form Number C11-206 for MultiFlex coil data.

COMBUSTIBLE FLOOR BASE DIMENSIONS

COMBUSTIBLE

FLOOR BASE

USE WITH

FURNACE SIZES

A

IN. [mm]

B

IN. [mm]

C

IN. [mm]

RXGC-B14

RGLH-05

14

1

/

2

[368] 13

1

/

4

[337] 11

1

/

4

[286]

RXGC-B17

RGLH-07, RGLH-10(-)A 18

[457] 16

3

/

4

[425] 14

3

/

4

[451]

RXGC-B21

RGLH-10(-)B

21

1

/

2

[546] 20

1

/

4

[514] 18

1

/

4

[464]

RXGC-B24

RGLH-12, RGLH-15

25

[635] 23

3

/

4

[603] 21

3

/

4

[552]

FURNACE

WIDTH

IN. [mm]

PLENUM

WIDTH

IN. [mm]

PLENUM ADAPTER

DOWNFLOW

COIL

PLENUM

14

[356]

16

1

/

4

[413]

RXAA-C178

RXAL-B16BU

14

[356]

20

1

/

4

[514]

RXAA-C179

RXAL-B20BU

17

1

/

2

[445]

16

1

/

4

[413]

RXAA-C186

RXAL-B16BU

17

1

/

2

[445]

20

1

/

4

[514]

RXAA-C180

RXAL-B20BU

17

1

/

2

[445]

21

5

/

8

[549]

RXAA-C189

RXAL-B21BU

17

1

/

2

[445]

25

1

/

4

[641]

RXAA-C181

RXAL-B25BU

21

[533]

25

1

/

4

[641]

RXAA-C183

RXAL-B25BU

24

1

/

2

[622]

25

1

/

4

[641]

RXAA-C184

RXAL-B25BU

21

[533]

22

1

/

4

[565]

RXAA-C182

RXAL-B22BU

24

1

/

2

[622]

21

5

/

8

[549]

RXAA-C190

RXAL-B21BU

GENERAL TERMS OF LIMITED WARRANTY

Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable
period stated, in accordance with the terms of the limited 
warranty.

For Complete Details of the Limited Warranty, Including Applicable Terms
and Conditions, See Your Local Installer or Contact the Manufacturer for
a Copy.

Gas Heat Exchanger Limited Warranty .......Twenty (20) Years
*Any Other Part..............................................One (5) Years

*This five year limited warranty is applicable only to single-phase products

installed in residential applications on or after January 1, 2001.

Summary of Contents for CRITERION II

Page 1: ...ic inlet connections with quick simple change Direct Spark ignition models and integrated board with humidifier and electronic air cleaner hookups Insulated blower compartment helps to reduce jacket loss and noise Pre paint galvanized steel cabinet Molded permanent filter Grab holes in doors to aid in easy door removal and replacement A variety of cooling coils and plenums designed to use with Rhe...

Page 2: ...not listed for use with fuels other than natural or L P propane gas The complete terms of limited and other warranties are available at our sales office or through local installer All models can be converted by a qualified Rheem distributor or local service dealer to use L P propane gas without changing burners Factory approved kits must be used to convert from natural to L P propane gas and may b...

Page 3: ... 10 AU 279 x 152 11 x 7 10 AM 279 x 178 11 x 10 279 x 254 11 x 10 279 x 254 3 4 4 PSC 559 1 2 4 PSC 373 3 4 4 PSC 559 3 4 4 PSC 559 9 5 7 1 9 5 9 5 MED LOW MED HIGH MED LOW MED LOW MED HIGH HIGH MED HIGH MED HIGH 1600 755 1200 566 2000 944 2000 944 50 12 50 12 50 12 50 12 25 55 13 9 30 6 55 85 10 AU 30 6 47 2 45 75 10 AM 25 41 7 40 70 22 2 38 9 40 70 22 2 38 9 155 68 3 190 87 8 190 87 8 180 82 2 1...

Page 4: ...esignates Metric Conversions MODEL RGLH SERIES A B C D E REDUCED CLEARANCES IN mm 05 14 356 1227 32 326 103 8 264 131 8 333 0 4 0 1 25 3 76 6 152 LEFT SIDE RIGHT SIDE BACK TOP FRONT VENT SHIP WGTS LBS kg 85 38 6 07 171 2 445 1611 32 415 121 8 308 165 8 422 0 3 0 1 25 3 76 6 152 105 47 6 10 A 171 2 445 1611 32 415 121 8 308 165 8 422 0 3 0 1 25 3 76 6 152 115 52 2 10 B 21 533 1927 32 504 137 8 352 ...

Page 5: ...0 835 LOW 935 441 910 429 885 418 855 404 825 389 785 370 760 359 10EBRJR 10NBRJR 11 x 10 279 x 254 3 4 559 LOW MED LO MED HI HIGH 1330 628 1690 798 0000 0000 1295 611 1670 788 2085 984 2410 1137 1285 606 1655 781 2055 970 2355 1111 1245 588 1615 762 2005 946 2305 1088 1225 578 1585 748 1970 930 2240 1057 1205 569 1565 739 1945 918 2165 1022 1160 547 1525 720 1880 887 2100 991 10EAME 10NAMER 11 x ...

Page 6: ... 111 4 286 RXGC B17 RGLH 07 RGLH 10 A 18 457 163 4 425 143 4 451 RXGC B21 RGLH 10 B 211 2 546 201 4 514 181 4 464 RXGC B24 RGLH 12 RGLH 15 25 635 233 4 603 213 4 552 FURNACE WIDTH IN mm PLENUM WIDTH IN mm PLENUM ADAPTER DOWNFLOW COIL PLENUM 14 356 161 4 413 RXAA C178 RXAL B16BU 14 356 201 4 514 RXAA C179 RXAL B20BU 171 2 445 161 4 413 RXAA C186 RXAL B16BU 171 2 445 201 4 514 RXAA C180 RXAL B20BU 1...

Page 7: ...Rheem Manufacturing Company 7 NOTES ...

Page 8: ...ovincial and Local codes regulations and practices RHEEM AIR CONDITIONING DIVISION 5600 Old Greenwood Road Fort Smith Arkansas 72908 In keeping with its policy of continuous progress and product improvement Rheem reserves the right to make changes without notice PRINTED IN U S A 11 01 DC FORM NO G11 449 REV 6 Supersedes Form No G11 449 Rev 5 ...

Reviews: