background image

Rheem Manufacturing Company

3

BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE
FROM YOUR RETAILER.

PHYSICAL DATA AND SPECIFICATIONS (UPFLOW)
U.S. AND CANADA MODELS

GENERAL TERMS OF LIMITED WARRANTY

Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable
period stated, in accordance with the terms of the limited 
warranty.

For Complete Details of the Limited Warranty, Including Applicable Terms
and Conditions, See Your Local Installer or Contact the Manufacturer for
a Copy.

Gas Heat Exchanger Limited Warranty .......Twenty (20) Years
*Any Other Part..............................................Five (5) Years

*This five year limited warranty is applicable only to single-phase products

installed in residential applications on or after January 1, 2001.

MODEL IDENTIFICATION—UPFLOW MODELS

[

] Designates Metric Conversions

MODEL NUMBERS
RGPL- SERIES

05EBMKR

05NBMKR

07EBRKR

07NBRKR

10EBRMR

10NBRMR

12EARMR

12NARMR

Temperature Rise Range °F
[°C]

25-55

[13.9-30.6]

30-60

[17-33]

40-70

[22.2-38.9]

35-65

[19.4-36.1]

High Input–BTU/Hr [kW] 

50,000 [15]

75,000 [22]

100,000 [29]

125,000 [37]

Heating Capacity–BTU/Hr [kW] 

40,900 [12]

61,280 [18]

81,470 [24]

101,660 [29]

Low Input–BTU/Hr [kW]

35,000 [10]

52,500 [15]

70,000 [20]

87,500 [25]

Heating Capacity–BTU/Hr [kW]

28,000 [8]

41,600 [12]

56,000 [16]

70,080 [20]

Heating–Ext. Static Pressure [kPa]

.10 [.025]

.12 [.029]

.15 [.037]

.20 [.05]

Blower (D x W) [mm]

11 x 7

[279 x 178]

11 x 10

[279 x 254]

11 x 10

[279 x 254]

11 x 10

[279 x 254]

ECM Motor H.P. [W]

3

/

4

[559]

1

/

2

[373]

1 [746]

1 [746]

Motor Full Load Amps.

9.6

7.7

12.8

12.8

Heating Speed CFM–High Fire [L/s]

860 [405]

1060 [500]

1320 [623]

1890 [892]

Heating Speed CFM–Low Fire [L/s]

648 [306]

700 [330]

942 [445]

1296 [573]

Cooling CFM @ .5" [kPa] E.S.P.
(Nominal) [L/s]

1200

[566]

1200

[566]

2000

[944]

2000

[944]

Max. E.S.P. (In. W.C.) [kPa]

0.5 [.12]

0.5 [.12]

0.5 [.12]

0.5 [.12]

Max. Outlet Air Temp. °F [°C]

155 [68.3]

170 [76.6]

170 [76.6]

180 [82.2]

Standard Filter Size–Inches
[mm]

15

3

/

4

x 25

[400 x 635]

19

1

/

4

x 25

[489 x 635]

19

1

/

4

x 25

[489 x 635]

22

3

/

4

x 25

[578 x 635]

Return Air Cabinets
(Opt.) RXGR-
Filter Size [mm]

C17B

(2) 12 x 16

[305 x 406]

C21B

(2) 20 x 16

[508 x 406]

C21B

(2) 20 x 16

[508 x 406]

C24B

(2) 24 x 16

[610 x 406]

AFUE 

80.5%

80.3%

80.0%

80.0%

07EBRQR

07NBRQR

30-60

[17-33]

75,000 [22]

61,280 [18]

52,500 [15]

41,600 [12]

.12 [.029]

11 x 10

[279 x 254]

3

/

4

[559]

9.6

1060 [500]

700 [330]

1600

[755]

0.5 [.12]

170 [76.6]

19

1

/

4

x 25

[489 x 635]

C21B

(2) 20 x 16

[508 x 406]

80.3%

115 [52]

Approx. Shipping Weight (Lbs.) [kg]

110 [50]

115 [52]

120 [54]

140 [63]

15

Maximum Overcurrent Protection

15

15

15

15

12.0

Unit Amps

8.7

8.7

12.0

12.0

➀ 

In accordance with D.O.E. test procedures.

➁ 

See Conversion Kit Index Form for high altitude derate.

R

G

P

L

07E

Furnace

B

R

K

R

Rheem

Gas

Upflow/

Design

Heating Input Designation

Horizontal

Series

Variations

Blower

Heating & Cooling

Fuel Type

M

= 11 x 7

[279 x 178 mm]

R

= 11 x 10

[279 x 254 mm]

K

= 600-1200 CFM

[283-566 L/s]

M

= 1200-2000 CFM

[566-944 L/s]

Q

= 1000-1600 CFM

[566-944 L/s]

Electric

Ignition

05E
07E
10E
12E

A

= Std.

Cabinet

B

= Wide

Cabinet

Designation

Designation

R

= Natural Gas,

U.S. and
Canadian
Standard
Furnace

Input

BTU/HR

50,000 [15 kW]
75,000 [22 kW]

100,000 [29 kW]
125,000 [37 kW]

NO

x

Model

05N
07N
10N
12N

Summary of Contents for CRITERION II PLUS 2 LXE RGPL- SERIES

Page 1: ...ible from upflow to horizontal left or right without field conversion Left or right side gas and electric inlet connections All models equipped with remote sense feature an inte grated board with humidifier and electronic air cleaner hookups Insulated blower compartment a slow open gas valve a specially designed draft inducer motor and blower motor make it one of the quietest furnaces on the marke...

Page 2: ...NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES STANDARD EQUIPMENT Completely assembled and wired 2 speed draft inducer high and low pressure switches redundant 2 stage main gas control blower compartment door safety switch solid state time on time off blower control limit control transformer direct drive multi speed blower motor Furnaces are equipped with cooling heating relay and transformer...

Page 3: ... 11 x 10 279 x 254 ECM Motor H P W 3 4 559 1 2 373 1 746 1 746 Motor Full Load Amps 9 6 7 7 12 8 12 8 Heating Speed CFM High Fire L s 860 405 1060 500 1320 623 1890 892 Heating Speed CFM Low Fire L s 648 306 700 330 942 445 1296 573 Cooling CFM 5 kPa E S P Nominal L s 1200 566 1200 566 2000 944 2000 944 Max E S P In W C kPa 0 5 12 0 5 12 0 5 12 0 5 12 Max Outlet Air Temp F C 155 68 3 170 76 6 170 ...

Page 4: ...and in accordance with local codes Designates Metric Conversions UPFLOW DIMENSIONS UPFLOW DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL INCHES mm MODEL RGPL A B C D E REDUCED CLEARANCES IN mm 05 171 2 445 1611 32 415 121 8 308 151 2 381 0 3 76 0 1 25 3 76 6 152 LEFT SIDE RIGHT SIDE BACK TOP FRONT VENT SHIP WGTS LBS Kg 105 47 6 07 10 211 2 533 1927 32 504 137 8 352 181 2 470 0 0 0 1 25 3 76 6 15...

Page 5: ...ZONTAL DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL INCHES mm WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR INSTALLATION ON ITS BACK WITH ACCESS DOORS FACING UPWARDS MODEL RGPL A B C D E REDUCED CLEARANCES IN mm 05 171 2 445 1611 32 415 121 8 308 15 381 0 3 76 0 1 25 3 76 6 152 LEFT SIDE RIGHT SIDE BACK TOP FRONT VENT SHIP WGTS LBS Kg 10 21 533 1927 32 504 137 8 352 181 2 470 0 0 0 1...

Page 6: ...RETURN AIR CABINETS A IN mm FILTER SIZE IN mm RXGR C17B 171 2 445 2 12 x 16 305 x 406 RXGR C21B 211 4 533 2 20 x 16 508 x 406 RXGR C24B 241 2 622 2 24 x 16 610 x 406 FOR HIGH ALTITUDES HIGH ALTITUDE KIT Required for all models at altitudes of 5 000 ft and above Use kit RXGY F13 for all GPL models OPTION CODE FOR HIGH ALTITUDE U S Canada 278 NOTE High altitude kits and options do NOT include additi...

Page 7: ...W 2000 944 1600 755 1400 661 1200 566 1 025 5 12 05 11 x 7 279 x 178 3 4 559 HIGH MED HI MED LOW 1200 566 1000 472 800 378 600 283 07 11 x 10 279 x 254 1 2 373 HIGH MED HI MED LOW 1200 566 1000 472 800 378 600 283 10 11 x 10 279 x 254 1 746 HIGH MED HI MED LOW 2000 944 1600 755 1400 661 1200 566 07 11 x 10 279 x 254 3 4 559 HIGH MED HI MED LOW 1600 755 1400 661 1200 566 1000 472 Note See Form Numb...

Page 8: ...rovincial and Local codes regulations and practices RHEEM AIR CONDITIONING DIVISION 5600 Old Greenwood Road Fort Smith Arkansas 72908 In keeping with its policy of continuous progress and product improvement Rheem reserves the right to make changes without notice PRINTED IN U S A 8 05 DC FORM NO G11 473 Rev 5 Supersedes Form No G11 473 Rev 4 ...

Reviews: