Installing  the  storage  tank.

4

Local  Installation  Regulations

This  storage  tank  must  be  installed  in  

accordance  with  these  instructions,  

local  or  federal  codes.
If  the  storage  tank  is  to  be  installed  in  

a  restaurant,  or  other  location  where  

NSF  International  listing  is  required,  

it  must  be  weather  sealed  to  the  floor,  

a  raised  base,  or  on  a  shelf  so  that  

seepage  cannot  accumulate  under  it;;  or  

elevated  to  provide  at  least  (6)  inches  

of  clearance  from  the  floor.

In  order  to  meet  NSF  International  

requirements  for  Standard  5,  the  

base  of  the  storage  tank  must  be  

sealed  to  the  floor  to  prevent  seepage  

underneath.    Apply  a  3/8"  bead  of  

RTV  Silicone  completely  around  the  

floor  edge  of  the  base  of  the  tank.

Location

The  location  chosen  for  the  storage  

tank  must  take  into  consideration  

the  following:

Locate  the  storage  tank  in  a  clean  dry  

area  as  near  as  practical  to  the  area  of  

greatest  heated  water  demand.  Long  

un-­insulated  hot  water  lines  can  waste  

energy  and  water.  
The  storage  tank  and  water  lines  

should  be  protected  from  freezing  

temperatures.  Do  not  install  the  

storage  tank  in  outdoor  unprotected  

areas  or  near  any  other  appliances  

where  high  temperatures  are  present,  

such  as  wood  burning  stoves,  boilers,  

or  furnaces.    High  temperatures  can  

warp  or  otherwise  damage  the  non-­

metallic  construction  of  this  storage  

tank.
Make  certain  the  floor  underneath  

the  storage  tank  is  strong  enough  to  

sufficiently  support  the  weight  of  

the  storage  tank  once  it  is  filled  with  

water.

Unit  

Capacity  

(Gallons)

Unit  

  Capacity  

  (Imperial  

Gallons)

Unit  

Capacity  

(Liters)

Dimensions  (Inches)

Height  

1

Diameter

Shipping  

Weight  

(lbs)

Approxi-­

mate  Full  

Weight  (lbs)

50

40

189

66  3/4

23  1/2

100

517

85

70

322

70  1/4

28  1/4

134

843

105

84

397

70  3/4

30  1/4

152

1,028

1

    

Height  includes  factory  installed  Temperature  and  Pressure  Relief  Valve.

Summary of Contents for 105 gallon

Page 1: ...o not understand these instructions or any terms within it seek professional advice Any questions regarding the operation maintenance service or warranty of this storage tank should be directed to the...

Page 2: ...in the Troubleshooting Guide If you review the chart of Troubleshooting Tips first you may not need to call for service READ THIS MANUAL Your safety and the safety of others are very important There...

Page 3: ...hored or strapped to resist falling or horizontal displacement due to earthquake motions For residential storage tanks up to 52 gallon capacity a brochure with generic earthquake bracing instructions...

Page 4: ...e storage tank in a clean dry area as near as practical to the area of greatest heated water demand Long un insulated hot water lines can waste energy and water The storage tank and water lines should...

Page 5: ...reate a rapid and dangerous pressure increase in the storage tank and system piping This rapid pressure increase can quickly reach the safety setting of the relief valve causing it to operate during e...

Page 6: ...emove or tamper with the vacuum relief valve for any reason Doing so will void the manufacturer s warranty The vacuum relief valve which must be used when installing the storage tank is factory instal...

Page 7: ...ER WITH CARE If sweat connections are used do NOT apply heat directly to any component directly connected to the storage tank This includes the cold water connection hot water connection temperature a...

Page 8: ...e using metal strapping or wire fastened to the structure overhead Seal Ring Inside nut Hex Union Nut Relief Valve No threads permitted on end of Drain Pipe 6 Maximum distance from drain pipe to suita...

Page 9: ...erty The manufacturer disclaims any responsibility for such loss or injury resulting from the use of such unauthorized devices CAUTION If local codes require the application of an external insulation...

Page 10: ...Air purged from storage tank and piping Water connections tight and free of leaks Temperature and Pressure Relief Valve properly installed and discharge line run to open drain Discharge line protected...

Page 11: ...your storage tank will provide years of dependable trouble free service It is suggested that a routine preventive maintenance program be established and followed by the user At least once a year lift...

Page 12: ...to Do Rumbling noise upon start up Normal settling of internal compo nents z No action required Relief valve producing popping noise or draining Pressure build up caused by thermal expansion in a clo...

Page 13: ...lief Valve 6 Nipple 3 4 NPT x 3 7 Reducer Bushing 3 4 NPT x 1 NPT 105 Gallon Only 8 Knock Out Bracket 9 Screw 8 x 3 4 10 Junction Box Cover 11 Screw 8 16 x 5 8 12 Water Connection Fitting 13 Screw SHC...

Page 14: ...14 Replacement Parts 50 85 105 gallon models 5 6 7 8 9 10 11 14 15 16 18 3 14 15 16 13 12 17 13 12 17 7...

Page 15: ...following address 3107 Sibley Memorial Highway Eagan MN 55121 1604 Phone 1 800 321 6718 When contacting the manufacturer the following information will be requested a Model and serial number of the s...

Page 16: ...ge from abuse accident fire flood freeze and the like 3 To damage or failure caused by operating the unit with an empty or partially empty tank 4 In the event the tank failure occurs due to the storag...

Reviews: