ACCESSORIES—UPFLOW

† Filter racks are shipped without filters.

Filters shipped with furnace may be used or a suitable 1" [25.4 mm] filter.

*Designates “E” or “N”.

RXPF-F01 and F02

FOSSIL FUEL KITS

are for use with Rheem Heat Pumps

and Criterion II warm air furnaces. The RXPF-F02 meets TVA
requirements.

ACCESSORY RETURN
AIR CABINETS

Return Air Cabinets may 
be installed on either side
application except RXGR-C24B
(side application must be
on side opposite gas and
electrical connections).

THE RXGR-C24B MUST ONLY BE INSTALLED ON THE SIDE
OPPOSITE THE GAS AND ELECTRICAL CONNECTIONS.

WARNING: IMPORTANT NOTICE

A SOLID METAL BASE PLATE (SEE TABLE) MUST BE IN PLACE WHEN THE FURNACE
IS INSTALLED WITH SIDE AIR RETURN DUCTS. FAILURE TO INSTALL A BASE PLATE
COULD CAUSE PRODUCTS OF COMBUSTION TO BE CIRCULATED INTO THE LIVING
SPACE AND CREATE POTENTIALLY HAZARDOUS CONDITIONS.

FURNACE

BASE

WIDTH

SOLID BOTTOM

BASE

PLATE SIZE

IN. [mm]

KIT NO.

PLATE NO.

IN. [mm]

14

[356]

RXGB-D14

AE-61874-01

11

5

/

8

x 23

9

/

16

[295 x 598]

17

1

/

2

[445]

RXGB-D17

AE-61874-02

15

1

/

8

x 23

9

/

16

[384 x 598]

21

[533]

RXGB-D21

AE-61874-03

18

5

/

8

x 23

9

/

16

[473 x 598]

24

1

/

2

[622]

RXGB-D24

AE-61874-04

25

5

/

8

x 23

9

/

16

[651 x 598]

[

] Designates Metric Conversions

RETURN AIR CABINETS

A

IN. [mm]

FILTER SIZE

IN. [mm]

RXGR-C24B

24

1

/

2

[622]

(2) 24 x 16 [610 x 406]

RXGR-C14B

14

[356]

(2) 12 x 16 [305 x 406]

RXGR-C17B

17

1

/

2

[445]

(2) 12 x 16 [305 x 406]

RXGR-C21B

21

[533]

(2) 20 x 16 [508 x 406]

FILTER RACK FILTER SIZES† INCHES [mm]

10*BRJ

MODEL

RGPH-

RXGF-CA

(SIDE)

05, 07, 10*A

15

3

/

4

x 25

[400 x 635]

15

3

/

4

x 25

[400 x 635]

12, 15

15

3

/

4

x 25

[400 x 635]

OPTION CODE FOR HIGH ALTITUDE: 

US—277
Canada—For high altitude derate procedure, refer to the furnace

installation instructions. 

(U.S. Models—Kit packaged with furnace. 

Requires field installation.)

EXTERNAL BOTTOM FILTER RACK:

RXGF-CB

Summary of Contents for 05EAUER

Page 1: ...sion Left or right side gas and electric inlet connections with quick simple change Direct spark ignition models utilize remote sense and fea ture an integrated board with humidifier and electronic ai...

Page 2: ...fan option for continuous fan common heat cool terminal OPTIONAL EQUIPMENT Side filter frame assembly Return air cabinet for all sizes See Page 6 NOTE Furnace is not listed for use with fuels other th...

Page 3: ...00 20 90 000 26 90 000 26 112 500 33 11 x 7 279 x 178 11 x 7 279 x 178 11 x 10 279 x 254 11 x 10 279 x 254 3 4 4 PSC 559 1 2 4 PSC 373 3 4 4 PSC 559 3 4 4 PSC 559 9 5 7 1 9 5 9 5 MED LOW MED HIGH MED...

Page 4: ...ARANCE TO COMBUSTIBLE MATERIAL INCHES mm MODEL RGPH A B C D E REDUCED CLEARANCES IN mm 05 14 356 1227 32 326 103 8 263 111 2 292 0 4 102 0 1 25 3 76 6 152 LEFT SIDE RIGHT SIDE BACK TOP FRONT VENT SHIP...

Page 5: ...FURNACE IS NOT APPROVED OR RECOMMENDED FOR INSTALLATION ON ITS BACK WITH ACCESS DOORS FACING UPWARDS MODEL RGPH A B C D E REDUCED CLEARANCES IN mm 05 14 356 1227 32 326 103 8 263 111 2 292 0 4 102 0...

Page 6: ...MBUSTION TO BE CIRCULATED INTO THE LIVING SPACE AND CREATE POTENTIALLY HAZARDOUS CONDITIONS FURNACE BASE WIDTH SOLID BOTTOM BASE PLATE SIZE IN mm KIT NO PLATE NO IN mm 14 356 RXGB D14 AE 61874 01 115...

Page 7: ...x 254 3 4 559 LOW MED LO MED HI HIGH 1270 599 1620 765 2010 949 2340 1104 1250 590 1595 753 1985 937 2275 1074 1220 576 1570 741 1960 925 2215 1045 1195 564 1545 729 1915 904 2145 1012 1165 550 1515 7...

Page 8: ...vincial and Local codes regulations and practices RHEEM AIR CONDITIONING DIVISION 5600 Old Greenwood Road Fort Smith Arkansas 72908 In keeping with its policy of continuous progress and product improv...

Reviews: