![Rheavendors Group barista XX Installation And Maintenance Manual Download Page 28](http://html1.mh-extra.com/html/rheavendors-group/barista-xx/barista-xx_installation-and-maintenance-manual_1451222028.webp)
to display the quantity of dispensing cycles you have performed;
to set up the machine clock;
to record any failure that may have occurred;
to check and enable product dispensing cycles;
it contains the maintenance control parameters of the machine;
to determine the RFID card parameters;
press key “2” when the display shows “key n” to scroll the variables
composing the function of that key;
- if you press “2” when “FUNCTIONING”, the key will perform the
function you have programmed (dispensing cycle of a drink);
see paragraph “functioning”;
- if you press “2” when “INHIBITED”, the key will be inhibited and
it will perform no function;
use key “2” to scroll the following items:
in E machines, espresso coffee is the first product you can
programme for each selection key; there are two variables:
- the water quantity in the cup; change it by means of “4” and
“5”; if the variable is zero, no espresso will be dispensed (drink
composed by instant products only);
- coffee will be dispensed before (value 1) or after (value 0) instant
products;
press “2” to display:
parameter used in machines complete with a time doser;
press keys “4” and “5” to change the rotation time of the N product
motor, thus changing the product quantity you have dispensed; if
time is zero, no product N will be dispensed; you can carry out a
“time test” on the set-point; (see 13.19.);
if the time you have programmed is other than zero, the N product
motor will be activated at the expiry of the delay time you have
programmed; the delay time is increased or decreased by pressing
keys “4” and “5”;
the rotation time of the product motor can be briefly interrupted
one or two times during the dispensing cycle (0 = no break);
in the “Latte macchiato” selection,
to establish the milk quantity of the second dispensing cycle;
to determine the delay of the second milk dispensing cycle;
to determine the breaks of the second milk dispensing cycle;
to establish the time interval between the first milk dispensing
cycle and the second one;
09.01.h. sales audit
09.01.i. clock
09.01.l. out of service
09.01.m. product qty
09.01.n. maintenance
09.01.o. RFID CARD
09.01.a. button from 1
to 8
“functioning”
LM dispensing
LM dispensing
LM dispensing
LM dispensing
programmazione
by
0-25 sec. 0.0
Pause A/B Latte M
MAN1920124 rel. 01 dated 23.09.2011
page no. 28 of 48 pages
SALES AUDIT
PRODUCT QTY
PROGRAMMING
CLOCK
PROGRAMMING
OUT OF SERVICE
REGISTRATION
MAINTENANCE
PROGRAMMING
RFID CARD
PROGRAMMING
FUNCTIONING
INHIBITED
0= inhib. 0.0
COFFEE WATER
1=coffee before 0.0
coffee sequence
grinder time
0= inhib. 0.0
PRODUCT N
PRODUCT N 0.0
start delay
0-1-2 00
breaks number
0= inhib. 0.0
PRODUCT LM Xn
PRODUCT LM 0.0
start delay
0-1-2 00
breaks number