RH TOLUCA 42100167 Owner'S Manual Download Page 7

TOLUCA FIRE TABLE OWNER’S MANUAL

  

13

  

WARNING: DO NOT USE SOLID FUEL, SUCH 

AS WOOD OR CHARCOAL, IN GAS FUELED 

FIRE TABLES.

Upon completing the gas line connection, a small 
amount of air will be in the lines. When the first 
lighting the burner, it will take a few seconds for the 
lines to purge themselves of this air.

Once the purging is complete, the burner will light 
and operate as indicated in the instruction manual 
Subsequent lighting of the appliance will not require 
purging unless the gas supply has been disconnected.

Inspect the gas hose before each use of the fire 
table. If the hose shows evidence of excessive 
abrasion or wear or if the hose is damaged, it must 
be replaced before using the fire table.

Inspect the burner before each use of the appliance. 
If there is any evidence that the burner is damaged, 
it must replaced before operating. Upon completing 
the gas line connection, a small amount of air will be 
in the lines. When first lighting the burner, it will take 
a few minutes for the lines to purge themselves of 
this air. Subsequent lighting of the appliance will not 
require such purging.

Never allow the ON/OFF valve to remain in the open 
position without placing a burning match on top of 
the burner 

FIRST!

You must have clear and easy access to the ON/OFF 
valve 

AFTER 

the appliance is installed and connected 

to the gas supply in order to safely turn of the burner.

Make sure the burner is in place prior to using 
the appliance. If the burner is damaged, install 
a replacement burner as specified by the 
manufacturer.

FOR YOUR SAFETY, READ BEFORE LIGHTING

•  Before operating the fire table, smell 

around the appliance area for gas 
odors. Be sure to smell the surrounding 
floor area as some gases are heavier 
than air and will settle on the ground.

•  Use only your hand to turn the manual 

gas control valve. Never use tools. If 
the valve will not turn by hand, do not 
try to repair it. Call a qualified service 
technician. Force or attempted repair 
may result in a fire or explosion.

LIGHTING INSTRUCTIONS

 

1.   Turn the ON/OFF valve located on 

the side of fire table completely to 
the 

ON

 position.

 

2.   Make sure fuel supply (LP or NG) is 

properly connected and turned on 
at the source. This will be either the 
LP tank or the NG valve.

 

3.   When you hear gas flowing, use 

either a long stem wooden match 
or a butane fireplace lighter to 
place a flame near the burner.

 

4.   If the burner does not light, does 

not stay lit, or the flame is very 
low, shut off the gas supply and 
wait five minutes to allow all fumes 
to clear. Start again from 

Step 

1,

 making sure all gas valves are 

completely opened.

TURNING OFF GAS

For NG Units: 

Turn the ON/OFF valve to the 

OFF

 

position at the unit for natural gas unit, then close 
the valve at the NG source.

For Propane Units: 

Turn the ON/OFF valve to the 

OFF

 position at the unit and then close the valve on 

the propane tank.

NOTE

The propane regulator in this appliance is equipped 
with a low flow protection device. Unless the propane 
cylinder valve is opened before the valve, the gas flow 
will be reduced resulting in a very small flame.

To reset this device, shut off the valve, disconnect 
the hose from the cylinder to relieve the pressure, 
then close the propane cylinder valve.

PROBLEM

POSSIBLE CAUSES

REMEDY

Will not light

Air in gas line

If new install, may take several 
attempts to purge air

Debris in gas line

Confirm gas line is clear 
(insulation, dirt, plastic, 
excessive pipe sealer, etc.)

Improper gas pressure

Confirm proper gas pressure 

Will not stay lit

Improper gas pressure

Confirm proper gas pressure

Improperly applied media

Review media application

Noise

Note:

 The movement and 

combustion of gas will 
create low, unavoidable 
levels of noise.

Passage of air/gas across 
irregular surfaces

Remove any tight bends or 
kinks in gas supply line

Excessive gas pressure on 
natural gas units

Check or reset gas regulator 
pressure

Unit is smoking/sooting 
excessively

Note:

 It is natural and 

unavoidable for appliance 
sets to produce moderate 
levels of carbon (soot) 
where flames contact  
the media

Poor fuel quality

Contact local natural gas 
company

Excessive flame impingement  
or blockage

Separate the media to allow 
more flame passage

Improper fuel and/or air 
mixture

Remove any foreign items from 
the flame pattern and check for 
proper orifice sizing

Burner flame is too low or 
too high

Incorrect gas supply or 
pressure

Check for proper gas supply 
pressure

Blocked burner orifice or 
burner ports

Free burner orifice and burner 
ports of any debris or blockage

Improper burner orifice size

Verify proper burner orifice 
sizing

Unit produces unwanted 
odors

Gas leak, see 

Warning 

Statement

Check for and seal all gas leaks

OPERATING THE FIRE TABLE

TROUBLESHOOTING

Summary of Contents for TOLUCA 42100167

Page 1: ...1 TOLUCA FIRE TABLES MODELS 42100167 42100171 42100189 42100190 OWNER S MANUAL...

Page 2: ...CSA Standards The following information regarding safe operation and maintenance of this appliance is a result of the tests performed by RADCO and certified by ICC ES SAFETY INSTRUCTIONS 4 GAS REQUIRE...

Page 3: ...exactly may result in fire or explosion causing property damage personal injury or loss of life We recommend installation is completed by professionals that are locally licensed by the authority havi...

Page 4: ...line pressure for propane is 11 W C Pressure Regulator The unit must be used with the supplied gas pressure regulator and hose assembly The regulator will control and maintain a uniform gas pressure...

Page 5: ...cm measured from bottom of fire table to flooring surface for ventilation VENTILATION Fresh air must be able to pass though installed vents to safeguard against residual gas accumulation Failure to al...

Page 6: ...stem Blowing bubbles in the soap solution indicates that a leak is present 5 Stop a leak by tightening the loose joint or by replacing the faulty part with a replacement part recommended by the manufa...

Page 7: ...hear gas flowing use either a long stem wooden match or a butane fireplace lighter to place a flame near the burner 4 If the burner does not light does not stay lit or the flame is very low shut off...

Page 8: ...all This limited warranty applies only to fire tables normally used for personal family or household purposes and specifically excludes rental or commercial applications This warranty is non transfera...

Page 9: ...52 2 2 ITEM NO PART QTY 1 51 1 Burner 1 2 63 11 Burner Plate 1 3 Coupling 1 4 2 Orifice Fitting 1 5 Male Flared Fitting 2 6 Flex Hose 3 Length 1 7 Key Valve 1 72 20 15 Fire Bowl 1 Gas Valve Key 1 ITE...

Page 10: ...MODEL ONLY 8 Propane Hose 10 Length 1 9 70 000btu LP Regulator 1 10 Quick Connect Fitting 1 NG MODEL ONLY 11 70 000btu NG Regulator 1 12 Street 90 1 DIMENSIONS PARTS LIST NG MODEL LP MODEL 24 24 1 Le...

Page 11: ...TOLUCA FIRE TABLE OWNER S MANUAL 030617 2017 RH and RESTORATION HARDWARE INC All rights reserved Other company names mention herein are trademarks of their respective companies...

Reviews: