16
value.
CAPACITANCE MEASUREMENTS
WARNING:
To avoid electric shock, disconnect power to
the unit under test and discharge all capacitors before
taking any capacitance measurements. Remove the
batteries and unplug the line cords.
1. Set the function switch to the
Ω
CAP position. (“nF”
and a small value will appear in the display).
2. Insert the black test lead banana plug into the negative (-)
jack (COM) and the red test lead banana plug into the
positive (+) jack (CAP).
Touch the test leads to the capacitor to be tested. The
display will indicate the proper decimal point, value and
symbol.
TEMPERATURE MEASUREMENTS
WARNING:
To avoid electric shock, disconnect both test
probes from any source of voltage before making a
temperature measurement.
1. Set the function switch to TEMP.
2. Insert the type K thermocouple probe black test lead
banana plug into the negative COM jack and the red test
lead banana plug into the positive Temp jack..
3. Touch the Temperature Probe head to the part whose
temperature you wish to measure. Keep the probe
touching the part under test until the reading stabilizes
(about 30 seconds).
4. Read the temperature in the display. The digital reading
will indicate the proper decimal point and value.
5. When setting "Celsius" or "Fahrenheit" into initial
state, please remove the battery cover and slip the