RGBlue MHD-44(AO) User Manual Download Page 17

 

Stock Code 873117        en.rgble.com      400-1661-021

 

r mac addr!   

Get network MAC 
address   

Mac address: 00:1C: 91:03:80:01   

s ip mode z!   

Set network IP 
mode to static IP or 
DHCP, z=0~1 (z=0 
Static, z=1 HDCP)   

Set IP mode: Static. 
Please use "s net reboot!" command or repower device 
to apply new config! 

r ip mode!   

Get network IP 
mode   

IP mode: Static   

s ip addr 
xxx.xxx. 
xxx.xxx!   

Set network IP 
address   

Set IP address:192.168.1.100 Please use "s net 
reboot!" command or repower device to apply new 
config! DHCP on, Device can't config static address, 
set DHCP off first.   

r ip addr! 

Get network IP 
address 

IP address:192.168.1.100 

s subnet 
xxx.xxx. 
xxx.xxx! 

Set network subnet 
mask 

Set subnet Mask:255.255.255.0 Please use "s net 
reboot!" command or repower device to apply new 
config! 
DHCP on, Device can't config subnet mask, set DHCP 
off first. 

r subnet! 

Get network subnet 
mask 

Subnet Mask:255.255.255.0 

s gateway 
xxx.xxx. 
xxx.xxx! 

Set network 
gateway 

Set gateway:192.168.1.1 Please use "s net reboot!" 
command or repower device to apply new config! 
DHCP on, Device can't config gateway, set DHCP off 
first. 

r gateway! 

Get network 
gateway 

Gateway:192.168.1.1 

s tcp/ip port 
x!   

Set network TCP/IP 
port (x=1~65535)   

Set tcp/ip port:8000   

r tcp/ip port!   

Get network TCP/IP 
port   

tcp/ip port:8000   

s telnet port 
x!   

Set network telnet 
port(x=1~65535)   

Set telnet port:23   

r telnet port!   

Get network telnet 
port   

telnet port:23   

s net reboot! 

Reboot network 
modules 

Network reboot... 
IP Mode: Static 
IP: 192.168.1.72 
Subnet Mask: 255.255.255.0 Gateway: 192.168.1.1 
Mac address: 00:1C:91:03:80:01 TCP/IP port=8000 
telnet port=10 

Note that you can send ‘RS232 command’ to control the Switcher via Serial Command tool. The 
‘Function description’ explains function about the command. The “Feedback” displays whether 
the command sends success or not and feedback the information you need to.   

 

Summary of Contents for MHD-44(AO)

Page 1: ...Stock Code 873117 en rgble com 400 1661 021 18Gbps 4K 60Hz With Audio De embedding 4X4 HDMI MATRIX SWITCHER MHD 44 AO User Manual VER 1 0...

Page 2: ...cal components that may be damaged by electrical spikes surges electric shock lighting strikes etc Use of surge protection systems is highly recommended in order to protect and extend the life of your...

Page 3: ...anagement is supported With its 18Gbps bandwidth and the additional features with latest HDMI standards This switcher can be controlled from the front panel RS 232 IR remote or TCP IP 2 Features 1 HDM...

Page 4: ...2K 30Hz 4 4 4 1080p 1080i 720p 720i 480p 480i All HDMI 3D TV formats All PC resolutions including 1920 x 1200 Output Scaling 4K to 1080p 3D Support Yes Color Space RGB YCbCr4 4 4 YCbCr4 2 2 YCbCr 4 2...

Page 5: ...ing Metal Enclosure Color Black Dimensions 220mm W 105mm D 44mm H Weight 792g Power Supply Input AC100 240V 50 60Hz Output DC12V 2 5A Locking connector Power Consumption 10W max 1 56W Standby Operatin...

Page 6: ...HDMI Input 1 to 4 HDMI Source inputs 1 to 4 2 HDMI Output 1 to 4 HDMI outputs for displays 1 to 4 3 Coaxial Audio OUT 1 OUT 2 OUT 3 OUT 4 RCA connector for coaxial audio output from HDMI OUT 1 OUT 2...

Page 7: ...e Switcher is in standby mode this state can be changed by using API commands or IR Remote or from the Web GUI interface B Selecting Inputs Manual Selection of the inputs is done by briefly pressing t...

Page 8: ...ock beep serial baud rate setting and firmware update Note these six pages are only accessible in Admin mode when User mode is used only the Status and Video pages are available To access the Web inte...

Page 9: ...og in details click the LOGIN button and the following Status page will appear Status page The Status page provides basic information about the product Model name the installed firmware version and th...

Page 10: ...nput page provides information about which inputs are connected and have a signal present The inputs can be giving more meaningful names if desired The EDID column provides a list of EDID options for...

Page 11: ...also be assigned meaningful names if desired The Output page provides information about the signal status of the outputs The Scaler mode menu provides the following options Bypass Follow the input sou...

Page 12: ...0 1661 021 System page The system page allows setting of the panel lock and beep on off control RS 232 port baud rate This page is also used to install new firmware update restore the factory default...

Page 13: ...Any carriage return that is present after the end of the command will be ignored 2 All spaces shown in the commands are required 3 All response messages are terminated by a CR LF sequence 4 When all f...

Page 14: ...r link out y Get the connection status of the y output port y 0 4 0 all HDMI OUT1 connect s reset Reset to factory defaults Reset to factory defaults System Initializing Initialization Finished s beep...

Page 15: ...1 enable Enable out 1 stream Disable out 1 stream r out y stream Get output y stream status y 0 4 0 all Enable out 1 stream s hdmi y scaler z Set hdmi output y port output scaler mode y 0 4 0 all z 1...

Page 16: ...Stereo Audio 2 0 8 3D Dolby DTS 5 1 9 3D HD Audio 7 1 10 4K2K30_444 Stereo Audio 2 0 11 4K2K30_444 Dolby DTS 5 1 12 4K2K30_444 HD Audio 7 1 13 4K2K60_420 Stereo Audio 2 0 14 4K2K60_420 Dolby DTS 5 1...

Page 17: ...st r subnet Get network subnet mask Subnet Mask 255 255 255 0 s gateway xxx xxx xxx xxx Set network gateway Set gateway 192 168 1 1 Please use s net reboot command or repower device to apply new confi...

Page 18: ...Stock Code 873117 en rgble com 400 1661 021 9 Connection Diagram...

Reviews: