background image

Address

S601-607, S504 Weiye Building Torch Hi-Tech Industrial Development Zone Xiamen, Fujian Province, P.R.C

Tel: 00865925771197

Fax: 00865925788216

Email: [email protected]

http://www.rgblink.cn

23

Output Brightness

>>

->Hot Backup

>>

Input Adjust

>>

Output Adjust

>>

Hot Backup

ON

Hot Backup Input

DVI1

Hot Backup 1

DVI2

Hot Backup 2

Module7

VGA Adjust

>>

USB Control

>>

Exit CVBS Control

>>

->Input Details

>>

Image Quality

>>

Zoom

>>

Mask

>>

->Change Mode

Together

DVI ALL

0

Hot Backup 3

DP

Hot Backup

Enter to <Advanced> menu, switch <Hot Backup> to <ON>, push knob to confirm, enter hot backup setting

menu.

Hot Backup is used for keeping output safety. If Hot Backup Input is out of working, then the selected Hot
Backup 1, Hot Backup 2 would shift as output automatically. The Hot Backup can be any signals from DVI1, DVI2,
DP and 3 optional input modules.

Input Adjust

Summary of Contents for VENUS X1PRO-E

Page 1: ...x 2K Seamless Splicing EDID management Modular 2K input Three slots for 2K input options 2K 2K and or 4K 2K matrix with cross conversion of any input signal to 2K DVI output Support remotely configur...

Page 2: ...tp www rgblink cn 1 CONTENT Product Introduction 2 Packing Configuration 3 Hardware Orientation 4 Front Panel 4 Back Panel 6 Using Your Product 7 Menu Structure 7 Standard Mode 8 Split Mode 12 Preview...

Page 3: ...nd output up to 8K1K or 4K2K pixel to pixel output VENUS X1PRO E with features like LOGO capture and standard test pattern built in EDID management Seamless switching between the inputs Support remote...

Page 4: ...l 00865925771197 Fax 00865925788216 Email sales rgblink com http www rgblink cn 3 Packing Configuration Note AC Power Cable supplied as standard according to destination market USB is contained on the...

Page 5: ...or 3 seconds will lock the front panel and push the button for 5 seconds to unlock Push the MENU and TAKE button for 3 seconds will switch the language 4 SCALE Button This button used for size and pos...

Page 6: ...on for USB signal 10 LOAD Button Restores Loads all current settings with the VENUS X1PRO E from 1 of the 24 available slots Additionally this button is used for direct numeric entry for numbers 6 11...

Page 7: ...cn 6 Back Panel Input Connectors 13 DVI Input DVI I Port 11 4K DVI2 Input Compatible HDMI 10 4K DP Input Input Option Slots 1 2 3 Input Option Slots Support SDI VGA DVI HDMI DP CVBS USB input Output...

Page 8: ...Torch Hi Tech Industrial Development Zone Xiamen Fujian Province P R C Tel 00865925771197 Fax 00865925788216 Email sales rgblink com http www rgblink cn 7 Using Your Product Menu Structure The menu st...

Page 9: ...nd scaled separately This is the default mode following a reset Output Resolution Setting 1 Push the MENU button enter to menu items and turn the rotary knob select Standard 2 Turn the rotary knob to...

Page 10: ...example input1536 as following 7 After the digital push the knob will add means before the is the vertical size and after the is the refresh rate Only digital 50 or digital 60 supports for the refres...

Page 11: ...will be on if the DVI signal is effective and stable If the DVI signal is invalid or no input DVI button light will flash Same with above switch the signals among DVI1 DVI2 DP and 3 option signals VEN...

Page 12: ...ect range between Mode1 Mode13 Image 1 4 Source Can select DV1 DV2 DP and 3 optional input signal by rotary knob or press signal on front panel directly Width Set width value Height Set height size va...

Page 13: ...K Mode Output Brightness Split Mode There are 12 split modes H1 2 V1 2 H1 4 V1 4 CROSS H 2 In 2Out V 2 In 2Out H 2 In 3Out H 2 In 4Out 3D Normal 3D Split H 1 2 3D Split V 1 2 Follows will provide samp...

Page 14: ...Split Mode CROSS PIP Config H Total 3840 V Total 2160 Width 1 1920 Height 1 1080 Details EDID 5 Return to Split Mode press the knob shows the follows select H 1 2 Set H total V total Width1 of screen...

Page 15: ...al as 2160 Width 1 as 1920 and Height 1 as 1080 then Width 3 will be 1920 H total 3840 Width 1 1920 Width 3 1920 Height 2 will be 1080 V total 2160 Height 1 1080 Height 2 1080 As shown in the figure b...

Page 16: ...8216 Email sales rgblink com http www rgblink cn 15 Reset Scale Width 1920 Height 1080 H Pos 0 V Pos 0 Output DVI4 Copy From Scale Crop Crop Edge Layer A Layer B Layer C Layer D 2 Select Details the m...

Page 17: ...MENU button and enter to menu items turn the rotary knob select Preview 2 Push the knob and enter to preview mode the mode including three functions Output Resolution Presentation Mode Switching Time...

Page 18: ...ital push the knob will add means before the is the horizontal size Same operation for vertical size for example input 1536 as following 7 After the digital push the knob will add means before the is...

Page 19: ...ion Mode Normal Image 1 Source DVI1 Width 1300 Height 1080 H Pos 0 V Pos 0 Image 2 Source DVI2 Width 1300 Presentation Mode PIP Image 1 Source DVI1 Width 1300 Height 1080 H Pos 0 V Pos 0 EDID Reset Pa...

Page 20: ...plit V H Total 1920 V Total 2160 Height 1 1080 Split H 1 Select Split H press the knob shows the follows 2 Set H total V total width1 of screen according to actual needs For example set H total as 384...

Page 21: ...Edge Layer A Layer B Layer C Layer D Output Resolution Presentation Mode Switching Time 0 1s Set Height 1 as 1080 and Height 2 will be 1080 V total 2160 Height 1 1080 Height 2 1080 2 Select Details t...

Page 22: ...Stand Alone Mode Stand Alone Mode can be set 4 DVI output port separately each output port can select any input signal but not support Fade in Fade out when switching each input signal allow to scale...

Page 23: ...Test Pattern Save Setting System Setting DVI 4 128 Change Mode Alone DVI 1 128 DVI 2 128 DVI 3 128 Advanced Setting 1 Push the MENU button and enter to menu items turn the rotary knob select Advanced...

Page 24: ...ackup 2 Module7 VGA Adjust USB Control Exit CVBS Control Input Details Image Quality Zoom Mask Change Mode Together DVI ALL 0 Hot Backup 3 DP Hot Backup Enter to Advanced menu switch Hot Backup to ON...

Page 25: ...Input Zoom Zoom Up Down Zoom Up Down Zoom Left Right Zoom Left Right Zoom Center Reset Parameters Mask Mask Left Right TOP Bottom Reset Mask VGA Adjust Can only be set by installing VGA input optional...

Page 26: ...upport Date Time Save to Load from Delay recall 1s Real Time Save Mode On TP mode Off Red 255 Green 255 Blue 255 Test Pattern Test Pattern Including TP mode off Color Bar Solid Color RGB Color adjust...

Page 27: ...age Setting English Factory Reset Factory Reset Yes SEL No Menu Language Setting 1 Push Menu turn the rotary knob to Language Setting push knob to confirm 2 Turn the knob to select English or Push the...

Page 28: ...ax 00865925788216 Email sales rgblink com http www rgblink cn 27 Using Black Out Black out descriptions Black signal realizes one key touch to a black screen VENUS X1PRO E provides black effect proces...

Page 29: ...ving Views VENUS X1PRO E provides 24 positions for saving or recording parameters To save current parameters and settings 1 Push the SAVE 1 button the button light is on and enable the SAVE function 2...

Page 30: ...is ready for recall Button flashes means just recall Recall Saving Settings VENUS X1PRO E provides 24 positions for saving or recording parameters To recall saved settings 1 Push the LOAD 6 button th...

Page 31: ...and are non transferable RGBlink warranties are only valid to the original purchase owner Warranty related repairs include parts and labor but do not include faults resulting from user negligence spec...

Reviews: