background image

Q2

User Manual

47

Chapter 5 Support

5.1 Contact us

Summary of Contents for Q2 Series

Page 1: ...1 Q2 Series User Manual Article NO RGB RD UM Q2 E002 Version NO V1 2 ...

Page 2: ... 2 Connect Input Signal Source 16 2 3 Connect Output Source 17 Chapter 3 Use Your Product 19 3 1 XPOSE 2 0 Installation 19 3 2 XPOSE Operation 22 3 2 1 Login in XPOSE 22 3 2 2 System Setting 24 3 2 3 Output Input Overview 28 3 2 4 Display Management 34 3 2 5 Layer Management 36 3 2 6 Preset Management 43 3 3 XPOSE APP Control 45 Chapter 4 Order Code 46 4 1 Product Code 46 4 2 Module Code 46 Chapte...

Page 3: ...ms and software on the date of commissioning at latest 30 days after the transfer of risks In the event of justified notice of compliant RGBlink can repair the fault or provide a replacement at its own discretion within an appropriate period If this measure proves to be impossible or unsuccessful the purchaser can demand a reduction in the purchase price or cancellation of the contract All other c...

Page 4: ...roduct input or output terminals A protective ground connection by way of the grounding conductor in the power cord is essential for safe operation Use the Proper Power Cord Use only the power cord and connector specified for your product Use only a power cord that is in good condition Refer cord and connector changes to qualified service personnel Use the Proper Fuse To avoid fire hazard use only...

Page 5: ...ntact your sales representative Once you have removed all the components from their packaging and checked that all the listed components are present visually inspect the system to ensure there was no damage during shipping If there is damage notify the shipping carrier immediately for all claims adjustments Site Preparation The environment in which you install your product should be clean properly...

Page 6: ...Q2 User Manual 6 Chapter 1 Your Product 1 1 In the Box AC Power Cord DVI Cable HDMI DVI Cable Network Cable Anti Static Bag Note AC Power Cable supplied as standard according to destination market ...

Page 7: ...upports RGBlink XPOSE 2 0 software operation Q2 SYSTEM CONNECTION DIAGRAM 1 2 1 Key Features Each module supports up to 8 layers Each layer support for scaling moving crossing and overlying Support 4K 60 inputs and outputs Each module supports for customized output resolution single port s width up to 3840 and height up to 3840 Optional independent audio input output modules XPOSE visualization op...

Page 8: ...Q2 User Manual 8 1 2 2 Front Panel 1 2 Q2 2 Q2 4 ...

Page 9: ...Q2 User Manual 9 1 2 3 Power Switch 3 Q2 8 ...

Page 10: ...indicates communication 1 Purple Input 1 3 Input slots 1 3 supporting DVI HDMI DP modules and other optional modules 2 Blue Output 1 2 Output slots 1 2 supporting HDMI and other optional modules 3 Yellow COMM Communication board with LAN and RS232 port to connect router or computer to realize software control 4 Power ...

Page 11: ...H 264 modules and other optional modules 2 Blue Output 1 5 Output slots 1 5 supporting HDMI DVI and other optional modules 3 Yellow COMM Communication board with LAN and RS232 port to connect router or computer to realize software control 4 Power Interface 4U and above supports double power ...

Page 12: ... and other optional modules 2 Blue Output 1 10 Output slots 1 10 supporting HDMI DVI and other optional modules 3 Yellow COMM Communication board with LAN and RS232 port to connect router or computer to realize software control 4 Power Interface 4U and above supports double power 4 2 Q2 8 3 1 ...

Page 13: ...Q2 User Manual 13 1 2 4 Dimension Following is the dimension of Q2 2 for your reference 446mm 370mm 89mm Q2 2 ...

Page 14: ...Q2 User Manual 14 Following is the dimension of Q2 4 for your reference 484mm 373mm 178mm Q2 4 ...

Page 15: ...Q2 User Manual 15 Following is the dimension of Q2 8 for your reference 488mm 370mm 355 6mm Q2 8 ...

Page 16: ... 2 Connect Input Signal Source Connect power and Q2 4 with standard AC Power Cord Take Q2 4 as example Q2 series supports HDMI DVI SDI DP1 2 HDBaseT and other optional input modules Connect Q2 4 with IP Camera PC DVD laptop and other device as shown in the figure above ...

Page 17: ...for single user to control the device Method 2 Router Connection Connect control computer and Q2 4 with Router as shown in the figure below It supports simultaneous online operation by multiple users Q2 Series supports SDI DVI HDMI HDBaseT and other optional output modules Connect Q2 4 with monitors Q2 series is operated by XPOSE so it is necessary to connect device with control computer ...

Page 18: ...ries supports preview input source via control computer or output image via monitor 2 6 Turn on Your Q2 LAN preview input and output HDMI monitor preview input source After connection slightly press the power button in the front panel to turn on Q2 ...

Page 19: ...y normally if the resolution is lower than 1920 1080 Operating system Windows 7 or above full version not Ghost version or compact version CPU i5 and above Mac Monitor Resolution must be 1680 1050 pixel or above it can not display normally if the resolution is lower than 1680 1050 CPU i5 and above 1 Double click it will pop up the installer language box select the language for example select Engli...

Page 20: ...ser Manual 20 2 Click Next to install 3 Click Browse to select the XPOSE software install location Click Install 4 During installation it will pop up the window of Install Shield Wizard for Virtual Com port ...

Page 21: ...Q2 User Manual 21 5 click Next 6 Then click Install as shown in the figure 7 Click Finish and complete the installation as shown in the figure below ...

Page 22: ...k Register and fill in the blank with first name last name email company and country and then click Register Now Please note that the email shall be invalid and complete otherwise Registration Activation code cannot be received Click Activate and scan the QR code an email from RGBlink Registrations will be sent to the Register email address Type in the activate code and confirm 8 Click Finish and ...

Page 23: ... Start Now If exact Name and Password are needed users can set up them in Authorization Setting under System Setting After login users can find the management including Topology Diagram Search Display System Layer Management Preset Management Keyboard Settings The details of each hierarchy will be described hereafter ...

Page 24: ...h Russia Find Device New version of XPOSE 2 0 is blank default in Find Device Users are supposed to choose the device needed in System Setting Keyboard Management click keyboard it will redirected to keyboard setting window Keyboard setting is designed to fit for different operation system such as Windows and Mac Users can set short cut keys ...

Page 25: ...ys you desired as shown in the figure Please note the keyboard area where allows to set short cut keys If the setting goes wrong or no need for short cut keys any more click to clear some keys or clear all Clear is to clear some keys the keys need to selected before hand Clear all is to remove all already set short cut keys Users can also save the keyboard setting as script Click Return to back to...

Page 26: ...users are allowed to operate Click the green block to remove the function not to be permitted Click new type in User Name and Password Prompt Message open and close unlock prompt and guide prompt Communication Setting The default is search if it is direct users need to type the corresponding IP address Serial Port search only those connect via serial port Ethernet Connection search only those conn...

Page 27: ...hird section in the IP address digits are the same XPOSE do operation on one device same operation synchronized to other devices For example there is another devices linked to the same network one with IP IP192 168 0 45 1 Set device numbers 2 Select the IP of the device in the drop down menu for Device IP 3 click ON the tow device are connected when the red pot turns to be green one 4 click OFF to...

Page 28: ...in the All Devices list such as Q2 SN ffff IP 192 168 0 20 2 click in the Chosen Device Resolution Click any output port the board where the port locates is selected Users can do settings to the port now A red rectangle flashes around the chosen port when it is clicked Note purple tip indicates input blue tip indicates output yellow tip indicates communication ...

Page 29: ...rt current output port Status ON OFF OSD Screen Group current group X Y the starting horizontal and vertical position Width Height the horizontal and vertical size of the text Font font of the text all fonts installed in the computer is available Font Type Normal Italic Bold Bold Italic Font size 0 300 pixels Color font color Customize Resolution Q2 supports to customize output resolutions Click a...

Page 30: ...iced by four outputs horizontally then type 7680 for width that is the width of the four outputs 3 Font choose font type size and color 4 After all settings done click Set and the OSD will be displayed on the screen Background Transparent Color background color Scroll Speed 0 16 Scroll Direction Scroll Off Scroll Left Scroll Right Input Text The exact content of the text After setting users choose...

Page 31: ...name Width Height Frequency type in custom parameters to meet your needs Q2 s modules which support EDID are as follows HDMI Input Module with video HDMI Input Module DVI M Input Module DVI I Input Module 4K 60 Input Mdule 4K 30 Input Module Order Codes of module refer to 4 2 Click any input port in purple area the board where the port locates is selected Users can do settings to the board now A r...

Page 32: ... be included in the address e g rtsp admin admin 192 168 1 176 554 cam realmonitor channel 1 subtype 0 unicast true proto Onvif in which admin admin is the account and password of camera 3 If only one camera s address is set click Set in the right directly If several cameras address are set together click set in the bottom of the page after all the address being finished Note For the account and p...

Page 33: ... restated in 30s Note After factory reset the device needs to be powered off and restarted and the IP will be reset to 192 168 1 200 Output Module Info users can check current output module name and MCU version Input Module Info users can check current input module name and MCU version indicates that there are no input modules as shown in the right figure ...

Page 34: ...ode Rotation Mode and Edge Blending In XPOSE2 0 Each mode is marked in different color and provided with fitted templates Q2 Presentation Mode only Users can do operations like splice under Presentation Mode Resolution Users can choose output resolution as shown in the figure Display System is for users to set layout of outputs Click this icon first and then click enter the interface Container Con...

Page 35: ... 3 columns and each display has a width of 1920 and a height of 1080 the total width will be 5760 and the total height will be 2160 Container Adjustment 1 Move Drag the boarder of the display area to move its place in the interface 2 Scale Click icon to shrink Click to enlarge the proportion of display area on interface 3 Cancel Long pressing the to cancel the screen group 2 Click Create the conta...

Page 36: ...t container Replacement Drag and drop the output into the corresponding Display The output being replaced will turns from gray to white in the list Q2 supports to manage 6 screen groups at most on XPOSE It allows users to edit the name of the Screen group that has been created just click the Layer Management is designed to manage the layer of each monitor Click this icon to enter the interface ...

Page 37: ...to confirm Q2 supports Audio Input Output Module which should be inserted into the slots supporting both input output module 1 Select a bank you would like to add audios Every bank and every layer can be added different audio inputs outputs 2 Drag audio inputs from Signal List to audio outputs as shown in the right figure You can also drag a new audio input to replace the previous one The relation...

Page 38: ...pectively Layer number Numbers in the corner is to show how many layers at present allowed to put in the output A 2K signal occupies one layer and a 4K2K60 signal occupies four layers The number in the red rectangle on the right figure represents the number of layers that can be placed at the output Layer Adjustment there are two ways to adjust layer 1 Use the bar under the interface Choose one la...

Page 39: ...mouse the icon turns to a fist moving the mouse can drag the layer Layer Remove Click the cross on the top right of the layer to remove the layer if needed Layer Set to crop the layer lock the layer to prevent misoperations max to cover up the monitor cover up all monitors in the same screen group with the one signal Layer Copy Press Ctrl and mouse left at the same time move the mouse the layer se...

Page 40: ... would like to set 2 Source Signal 3 Drop Area Drag the source from the Signal List to the Drop Area Drag as many signals as you need such as signal 1 and signal 2 into the drag area 4 After setting click Set to confirm and the layout will be shown on the interface as shown in the right figure ...

Page 41: ...Turn on Layer Preview Input Preview Scene Preview or Expand Preview according to the actual need 2 Turn on H 264 and users can preview the image as shown in the right figure Note H 264 is the master switch If the user turns on H 264 first it cannot be set successfully ...

Page 42: ...rder Codes of modules refer to 4 2 Operation steps are as follows 1 Turn on Edit Status 2 Click Browse to choose picture 3 Position fill in the X Y and Width Height 4 After settings click Set to confirm and click Clear Image to clear the image if needed 5 After click Set the background is set successfully when red progress bar at the bottom of the interface turns to green Hotkey ...

Page 43: ...n and choose a new color for the boarder of chosen bank Preset Management is designed to switch bank scene setting done in last step Preset Management Mode 1 Manual Mode 2 Schedule Mode The chosen scene will be displayed in the main interface and the PGM screen is in the first in the Bank Column Click Script fill in the file name and click Save the file can be seen in the Load Script Click Load to...

Page 44: ...edule Mode This mode is designed to set auto bank scene preset switch Steps are as follows 1 Choose the BANK 2 Fill in the Start Time and End Time 3 Turn on Daily Loop and click OK 4 Click to edit and to delete 5 Turn on Loop Switch ...

Page 45: ...irst and then click to open it click search 2 Select Q2 model and click the icon in the top right corner 3 Fill in the IP address of Q2 and then click OK Now the device and Q2 is connected Load Scene Red indicates current scene green indicates the save scene white indicates blank scene e g As shown in the right picture it is in Group 1 Scene2 click 1 to switch to Group 1 Scene If you need to load ...

Page 46: ... 10 0 Q2 Quad HDBaseT 1080P Input Module 791 0020 11 0 Q2 Single H264 IP Input Module 791 0020 12 0 Q2 Quad 3G SDI Input Module 791 0020 13 0 Q2 CVBS Input Module 791 0020 21 0 Q2 Quad 2K HDMI 1 3 Output Module 791 0020 22 0 Q2 Quad 2K DVI Output Module 791 0020 23 0 Q2 Quad 2K DVI Output Module with OSD background 791 0020 24 0 Q2 Quad 2K HDMI Output Module with OSD background 791 0020 25 0 Q2 Du...

Page 47: ...Q2 User Manual 47 Chapter 5 Support 5 1 Contact us ...

Page 48: ...nput 4 Connector Type DVI I Input Resolution 800 600 60 1920 1200 60 Quad HDMI1 3 Input Connector Appearance Numbers of Input 4 Connector Type HDMI A Supported Standard HDMI 1 3 Input Resolution 800 600 60 1920 1200 60 Quad HDMI1 3 Input with Audio Connector Appearance Numbers of Input 4 Connector Type HDMI A Supported Standard HDMI 1 3 Input Resolution 800 600 60 1920 1200 60 Dual HDMI1 4 4K inpu...

Page 49: ...andard HDMI 2 0 DP1 2 Input Resolution 800 600 60 7680 1080 60 Quad HDBaseT input Connector Appearance Numbers of Input 4 Connector Type 2 RJ45 Input Resolution 800 600 60 1920 1080 60 Single IP input Connector Appearance Numbers of Input 1 Connector Type RJ45 Input Resolution 800 600 60 1920 1080 60 Quad SD HD 3G SDI input with loop out Connector Appearance Numbers of Input 8 Connector Type 8 BNC...

Page 50: ...ector Type HDMI A Supported Standard HDMI1 3 Output Resolution 800 600 60 3840 570 60 Key Feature Support background and scrolling OSD Dual HDMI1 4 4K30 output Connector Appearance Numbers of Input 2 Connector Type HDMI A Supported Standard HDMI1 4 Output Resolution 800 600 60 3840 2160 30 Dual HDMI2 0 4K60 output Connector Appearance Numbers of Input 2 Connector Type HDMI A Supported Standard HDM...

Page 51: ...ly used on earlier computers The signal is non interlaced in modes 1 2 and 3 and interlaced when using in mode DVI Digital Visual Interface The digital video connectivity standard that was developed by DDWG Digital Display Work Group This connection standard offers two different connectors one with 24 pins that handles digital video signals only and one with 29 pins that handles both digital and a...

Page 52: ...d support for 10 bpc 12 bpc and 16 bpc color depth 30 36 and 48 bit px called deep color HDMI 1 4 Released on June 5 2009 added support for 4096 2160 at 24 Hz 3840 2160 at 24 25 and 30 Hz and 1920 1080 at 120 Hz Compared to HDMI 1 3 3 more features added which are HDMI Ethernet Channel HEC audio return channel ARC 3D Over HDMI a new Micro HDMI Connector an expanded set of color spaces HDMI 2 0 Rel...

Page 53: ...on than splicing The connectors mechanically couple and align the cores of fibers so light can pass 4 most common types of optical fiber connectors are SC FC LC ST SC Subscriber Connector also known as the square connector was also created by the Japanese company Nippon Telegraph and Telephone SC is a push pull coupling type of connector and has a 2 5mm diameter Nowadays it is used mostly in singl...

Page 54: ... reason the hue control is not needed on a PAL TV set PAL is widely used in needed on a PAL TV set PAL is widely used in Western Europe Australia Africa the Middle East and Micronesia PAL uses 625 line 50 field 25 fps composite colour transmission system SMPTE Society of Motion image and Television Engineers A global organization based in the United States that sets standards for baseband visual c...

Page 55: ... standards that allow audio video digital compression and Transmission H 264 Also known as AVC Advanced Video Coding or MPEG 4i is a common video compression standard H 264 was standardized by the ITU T Video Coding Experts Group VCEG together with the ISO IEC JTC1 Moving Picture Experts Group MPEG H 265 Also known as HEVC High Efficiency Video Coding H 265 is the successor to the widely used H 26...

Page 56: ...not the intensity Gamma The light output of a CRT is not linear with respect to the voltage input The difference between what you should have and what is actually output is known as gamma Frame In interlaced video a frame is one complete image A video frame is made up of two fields or two sets of interlaced lines In a film a frame is one still image of a series that makes up a motion image Genlock...

Page 57: ...imilar range of luminance to that experienced through the human visual system UHD Standing forUltra High Definition and comprising 4Kand8Ktelevision standardswitha16 9ratio UHD follows the 2K HDTV standard A UHD 4K displayhasaphysicalresolutionof3840x2160 which is four times the area and twice both the widthandheightofaHDTV FullHD 1920x1080 video signal EDID Extended Display Identification Data ED...

Reviews: