background image

 

 

 

                                                                     

Stock Code 873117        en.rgble.com      400-1661-021

                                                       

9

  / 

9

 

 

P/N: U00301 

Notice

 

To ensure that the device use reliably and personal safely. Please abide by following items 
when install, useful and maintain. 
 
Notice when the installation 

 

Do  not  use  this  product  at  the  following  place:  the  place  has  ash,  lamp  base,  electrical 
conductivity dust

corrosive gas and flammability gas etc. 

 

The screw hole is processing and wiring, the metal filing and wire head do not fall into aspirail. 
Because it may lead to fire, malfunction or mis operation etc. 

 

The product has finished installation. To ensure has not foreign matter on vent. Otherwise it 
may lead to fire, malfunction or mis operation when operating has not heat dissipation well.

 

 
Notice when the wiring: 

 

When the product is installing or wiring before the power supply must turn off. Otherwise it 
may lead to electric shock or the device damage. 

 

This product connects the grounding conductor 

throu

gh power line. To avoid electric shock, 

the grounding conductor must connect grounding. 

 

When it has finished wiring, you should 

clear foreign matter. Please cover the terminal plate well before power on to avoid electric 
shock. 
 
Notice when the operational and maintenance: 

 

Do not touch the terminal when connecting the power supply. Otherwise it may lead to electric 
shock or mis operation. 

 

After turn off the power supply to clear and   
terminal screw. It will lead to electric shock when connecting the power supply.   

 

Do not remove the device to avoid damage   
electrical components 

 

Be sure to read this manual. After make sure safe to make change the  program, operation 
and stop operation. 
 

Notice when the products scrap: 

 

The electrolytic capacitor on the circuit board burn lead to explode. 

 

Please classified collection and disposal. Do not get to household garbage. 

 

Please classified disposal or according to the environmental regulations to disposal.

 

 

 

Summary of Contents for UT-150FHD-TR

Page 1: ...Stock Code 873117 en rgble com 400 1661 021 P N U00301 HDMI 150M HDBT Extender with HDMI Loop out UT 150FHD TR User Manual VER 1 0 ...

Page 2: ...ice recommended This product contains sensitive electrical components that may be damaged by electrical spikes surges electric shock lighting strikes etc Use of surge protection systems is highly recommended in order to protect and extend the life of your equipment Table of Contents 1 Introduction 2 2 Features 2 3 Package Contents 2 4 Operation Controls and Functions 3 4 1 Panel introduction 3 4 2...

Page 3: ...r 2 Features HDMI 1 4 HDCP 1 4 and DVI 1 0 compliant Video resolutions up to 1080p 60Hz YUV4 4 4 HDMI High Bit Rate HBR audio pass through 150 meters transmission distance over CAT6 cable POC Power over Cable either TX or RX is powered by one 24V 1A power supply See item 4 2 Connection diagram description 1 Bi directional infrared control signal transmission See item 4 2 Connection diagram descrip...

Page 4: ...or PS4 player HDMI OUT Connect to HDTV or monitor HDMI input port IR IN Channel 2 IR Receiver Connect to an IR receiver cable IR OUT Channel 1 IR Transmitter Connect to an IR emitter cable RS 232 Phoenix jack provide serial port control from two way transmission between transmitter and receiver Connection Signal Indicator Lamp Illuminate The Transmitter and Receiver are in good connections status ...

Page 5: ...t IR IN Channel 1 IR Receiver Connect to an IR receiver cable IR OUT Channel 2 IR Transmitter Connect to an IR emitter cable RS 232 Phoenix jack provide serial port control from two way transmission between transmitter and receiver Connection Signal Indicator Lamp Illuminate The Transmitter and Receiver are in good connections status Flashing The Transmitter and Receiver are in poor connections st...

Page 6: ...400 1661 021 5 9 P N U00301 4 2 Connection diagram Description 1 POC Power over Cable Application Example Description 2 Bidirectional Infrared control Application Example Description 3 Bidirectional RS 232 control Application Example ...

Page 7: ...arge Connections Transmitter UT HS T Inputs 1 HDMI Type A 19 pin female 1 IR INPUT 3 5mm Stereo Mini jack 1 RS232 Phoenix jack Outputs 1 HDBT Out RJ45 1 HDMI Type A 19 pin female 1 IR OUTPUT 3 5mm Stereo Mini jack Receiver UT HS R Inputs 1 HD BaseT in RJ45 1 IR INPUT 3 5mm Stereo Mini jack Outputs 1 HDMI Type A 19 pin female 1 IR OUTPUT 3 5mm Stereo Mini jack 1 RS232 Phoenix jack General Housing A...

Page 8: ...Stock Code 873117 en rgble com 400 1661 021 7 9 P N U00301 6 Connection Diagram ...

Page 9: ...nents Please protect the environment Through the EU conference and the EU council 2002 95 EC command The product has reached the EU command safety requirements User can use securely This is a class A product In life environment this product will lead to radio interference when you use it In this moment you need take measures to interference The uninsulated dangerous voltage can cause people suffer...

Page 10: ...ad to electric shock or the device damage This product connects the grounding conductor through power line To avoid electric shock the grounding conductor must connect grounding When it has finished wiring you should clear foreign matter Please cover the terminal plate well before power on to avoid electric shock Notice when the operational and maintenance Do not touch the terminal when connecting...