1.

 

Specifications 

Dimensions (WxHxD) 

168mm x 192mm x 86mm / 6.6in x 7.6in x 3.4in 

Light field diameter: 

70mm / 2.8in 

Acceptable input voltage range (long-term): 

100 ÷ 240 VAC 

Acceptable input voltage range (short-term): 

85 ÷ 264 VAC 

Acceptable input voltage frequency range: 

47 ÷ 63 Hz 

Operating temperature (ambient): 

-25°C ÷ 45°C / -13°F ÷ 113°F 

Operating temperature (device surface): 

-25°C ÷ 70°C / -13°F ÷ 158°F 

Average power consumption: 

5W 

Ingress protection rating

1

 IP: 

65 

Weight: 

1.5kg / 3.3lbs 

2.

 

Transport and storage 

The  device  is  sensitive  to  mechanical  damages.  Care  should  be  taken  to  properly  protect  the  device  during 
transport  so  as  to  eliminate  any  damage.  It  is  forbidden  to  transport  the  device  components  separately  in  a 
collective package – each component must be packed separately and cannot 'bump' during transportation.  

Due  to  protective  packaging,  the  device  should  be  stored  in  the  temperature   -25°C  ÷  +60°C  [-13°F  ÷  140°F] 
at the humidity below 99%RH. 
 

3.

 

Device construction 

TL-70-2-  is  cased  in  a  powder-coated  steel  housing.  The  properly  installed  device  meets  the  IP65  tightness 
requirements. 

3.1

 

TL-70-2 construction 

The figure shows the TL-70-2 light signalling device

2

 

det.  A

 -roof; 

det. B 

- controller; 

det. C -

 back cover; 

det. D

 - roof  fixing screw; 

det.

 

E

 - light field; 

det. F 

- device front; 

det. G - 

LED module; 

det. H 

- back cover fixing screws; 

Fig. 1 

3.1.1

 

List of the signalling device cables 

1

 

Five-metre  power  lead  (3  x  1mm²  [17AWG],  core  markings:  blue,  brown,  yellow-and-green),  terminated 
with WAGO connectors on each core. 

2

 

Five-metre signal cable (3 x 0.25mm² [24AWG], core markings: black - GND, red - red button/switching on 
red  light,  orange  -  green  button/switching  on  green  light),  terminated  with  WAGO  connectors  on  each 
core. 

                                                           

1

 Ingress protection rating defined according to the EN 60529 standard. 

2

 

Explanatory figure 

Summary of Contents for 319-01-01

Page 1: ...OPERATION AND MAINTENANCE MANUAL TL 70 2 Product code 319 01 01 Explanatory figure ...

Page 2: ...1 1 Embedded user menu DEF microbutton 5 4 3 1 2 Interface transmission and communication speed parameters 6 5 Controller 6 5 1 Controller connectors 6 5 2 List of the LED module conectors 7 5 3 List of the signalling device connectors 7 5 3 1 RS 232 connector 8 5 3 2 RS 485 RS 422 connector 8 5 3 3 0 20mA digital current loop 8 5 3 4 Operator panel dry contact 8 6 Automatic brightness control of ...

Page 3: ...ot bump during transportation Due to protective packaging the device should be stored in the temperature 25 C 60 C 13 F 140 F at the humidity below 99 RH 3 Device construction TL 70 2 is cased in a powder coated steel housing The properly installed device meets the IP65 tightness requirements 3 1 TL 70 2 construction The figure shows the TL 70 2 light signalling device2 det A roof det B controller...

Page 4: ...tallation of the device ensures its proper operation and the maintenance of the device parameters like among others the housing tightness rating satisfying the required IP code NOTICE Before any installation or maintenance operations refer to the manual supplied by the manufacturer Improper connection to the mains power supply incautious device installation or improper use may cause the property d...

Page 5: ...otocol with a control module such as a weighing terminal an operator panel 2 Determining the response to the events reported by the control module 4 3 1 Defining communication protocols 4 3 1 1 Embedded user menu DEF microbutton The user menu embedded in the device allows you to select a communication protocol display the information about the software version display the set protocol reset to the...

Page 6: ...the default light signalling device protocol In addition in the devices with the Ethernet interface you can restore the default network layer settings IP address 192 168 0 11 network mask 255 255 255 0 and the communication port for the control module To restore the default settings you should during the normal operation of the device press the microbutton and hold it down until the inscription R ...

Page 7: ...ctors Table 2 contains the description of the connectors in the light signalling device The connectors are accessible after the disassembly of the back cover and the LED module mounted on this cover det A device front det B controller det C back cover det D LED module Fig 9 NOTICE The housing should be disassembled with the disconnected power supply ...

Page 8: ...he RS 485 or RS 422 connector Fig 7 using the control module 5 3 3 0 20mA digital current loop For the communication purposes the user connects with the controller via the digital current loop connector Fig 7 using the control module 5 3 4 Operator panel dry contact For the control purposes the user manipulates the operator panel or relay contacts 6 Automatic brightness control of the light signal...

Page 9: ...gregated and then recycled in accordance with the local executive regulations on waste disposal 9 2 Device disposal The device must not be disposed of as urban waste In accordance with the directive 2002 96 EC WEEE if the repair of the device is not economically justified the user must take the damaged or destroyed equipment to a special waste disposal centre 10 Most common installation errors 1 I...

Reviews: