background image

Vicki works with the majority of radiator 

valves.

Default radiator valve fitting: M30x1.5

Available adaptors: RA, RAV, RAVL, ORAS, 

Oventrop

In order to operate Vicki, you will need:

LoRaWAN network

Batteries

Battery type: 2xAA (1.5VDC each)

Device operating voltage: 2.7 - 3.6VDC

Description:

 MClimate Vicki LoRaWAN - Smart Radiator Thermostat

Developed & Manufactured by MClimate™

Model:

 MC-LW-V02

Dimensions:

 54x78x50mm

Weight: 

107gr.

Wireless technology:

 LoRaWAN® 1.0.3

LoRaWAN Security: 

LoRaWAN® End-to-End encryption  (AES-CTR)

LoRaWAN Device type:

 Class A End-device

Supported LoRaWAN Features:

 OTAA, ADR, Adaptive Channels setup

Supported LoRaWAN  Regions:

 EU868 – 870

Link budget:

 130dB

RF Transmit power: 

14dB

Power supply: 

3V (2 x AA batteries)

Sensors:

 temperature and humidity

Work temperature: 

0°С to +60°С

Material: 

ABS + Glass

Environmental conditions, in which the device is intended to operate:

- Indoor only;

- Altitude up to 2000m;

- Ambient temperature: 0°С to +60°С;

-  Maximum  relative  humidity  of  80%  for  temperature  up  to  31°С, 

decreasing

linearly to 25% relative humidity at

temperature of 50°С;

- Environment with contamination degree 2 (PD2).

Storage and transportation conditions:

- Ambient temperature :-40°С to +85°С;

- Relative humidity 5% to 90% without condensation

Manufacturer

Melissa Climate Jsc

Gen. Gurko 4 street

1000 Sofia,Bulgaria

Compliance with the WEEE Directive

The appliance marked with this symbol should not be disposed of with 

other  household  waste.  It  must  be  handed  over  to  the  relevant 

collection point for the recycling of electrical and electronic equipment.

Legal Notices

EU Declaration of Conformity

This device complies with the essential requirements and 

other applicable provisions of the following EU directives:

Health: EN 62479:2010

2014/35/EU Low Voltage Directive: 

EN 60950-1:2006 / A11:2009 / A1:2010 / A12:2011 / A2:2013

2014/30/EU EMC Directive: 

EN 301 489-1 V2.1.1

EN 301 489-3 V2.1.1

Radio Equipment Directive (RED): 

EN 300 220-1 V3.1.1

EN 300 220-2 V3.1.1

You can find a copy of the Declaration of 

Conformity at:

www.mclimate.eu/conformity

All  information,  including  but  not  limited  to,  features, 

functionality,  and  /  or  other  product  specifications  are 

subject to change without notice. MClimate retains all rights 

to review or update its products, software or documenta-

tion  without  being  required  to  notify  any  private  or  legal 

person. The MClimate and MClimate logo are trademarks of 

Melissa  Climate  Jsc.  All  other  brands  and  product  names 

mentioned  herein  are  trademarks  of  their  respective 

owners.

Please  read  the  safety  instructions  before  installing  the 

device! Failure to follow the recommended instructions in 

this manual may be dangerous or in violation of the law. The 

manufacturer Melissa Climate Jsc., is not responsible for any 

loss or damage caused by failure to follow the instructions 

in the operating manual. 

 Technical specifications

Compatibility

Safety Instructions

Summary of Contents for LoRaWAN Vicki

Page 1: ...Installation guide ...

Page 2: ... Link daneben German För att ta reda på hur du installerar Vicki skanna QR koden eller besök länken bredvid den Swedish Lai uzzinātu kā instalēt Vicki skenēt QR kodu vai apmeklējiet saiti blakus tai Latvian Para saber como instalar Vicki digitalize o código QR ou visite o link ao lado dele Portuguese Para saber cómo instalar Vicki escanee el código QR o visite el enlace al lado Spanish Norėdami su...

Page 3: ...Inside the box Vicki Vicki s backplate User manual ...

Page 4: ...ve The appliance marked with this symbol should not be disposed of with other household waste It must be handed over to the relevant collection point for the recycling of electrical and electronic equipment Legal Notices EU Declaration of Conformity This device complies with the essential requirements and other applicable provisions of the following EU directives Health EN 62479 2010 2014 35 EU Lo...

Page 5: ... 2 Insert 2xAA 1 5VDC batteries and fix the battery cover tightly in place Recommended batteries Energizer Lithium Ultimate L91 Device does not operate with rechargeable batteries 3 backplate battery metal cover After successfully inserting the batteries and closing the metal battery plate the device will display Hi 4 Batteries display ...

Page 6: ...nt Vicki on the thermostatic valve Insert Vicki on the backplate 3 Installation Warning If you already have a thermostatic valve during installation no water will leak If you don t have a thermostatic valve please call a specialist and ask them to replace your valves thermostatic valve Apply moderate pressure with your palm on Vicki s display and rotate the device clockwise to secure it on the bac...

Page 7: ...pKey a0658dfae72131saf1249abc11 Register You can get DevEUI AppEUI JoinEUI AppKey information from the LoRaWAN credentials csv file we sent you with the fulfillment confirmation 1 Open your LoRaWAN Network provider access panel and add the device using the supplied Serial Number DevEUI AppEUI JoinEUI and AppKey Installation The data is example Do not use ...

Page 8: ...Callibration If Vicki s batteries are running low she indicates that by showing a Lo message on the display If Child lock is activated Vicki s display will show Ch and the manual temperature control will be disabled Once you attach Vicki to the radiator a calibration process will be initiated The aim of the calibration process is to let Vicki know the kind of valve she is attached to During calibr...

Page 9: ...Designed Manufactured by MClimate in Europe www mclimate eu ...

Reviews: