MODULES ACCESS POINTS MAP
Ref.
DESCRIPTION
1
DUPLEXER - BTS side - Up Link path SMA connector
2
LNA - Down Link - input
3
Band Selective 2 Up-Link path output
4
DUPLEXER - BTS side - input/output SMA connector
5
Directional coupler - BTS side - SMA (f) input/output connector
6
DUPLEXER - BTS side - SMA Down Link connector
9
LNA - Up Link path - output
10
Band Selective 1 Up Link Input
11
Band Selective 1 Down Link Output
12
Band Selective 2 Down Link Input
13
LNA - Down Link path - output
14
LNA - Up Link path - input
15
Band Selective 2 Up Link path input
16
Band Selective 2 Down Link path output
17
Band Selective 1 Down Link path Input
18
Band Selective 1 Up Link path output
21
DUPLEXER - MS side - Up Link path SMA connector
22
48Vdc ONLY circuit breaker
23
DUPLEXER - MS side - input/output SMA connector
24
Directional coupler - MS side - SMA (f) input/output connector
25
DUPLEXER - MS side - Down Link path SMA connector
26
GREEN LED: +5Vdc available
GREEN
HPA - UP LINK - communicates with management
unit
27
GREEN / RED LED
HPA UP
RED
HPA - UP LINK - does not communicate with
management unit
28
GREEN LED: +10.5V available
GREEN
HPA - DOWN LINK - communicates with
management unit
29
GREEN / RED LED
HPA DOW N
RED
HPA - DOWN LINK - does not communicate with
management unit
30
HPA Down Link output
31
Sub-D 15-pole management link between Down Link HPA and management unit
32
HPA Down Link input
33
HPA Down Link monitoring SMA connector
34
Sub-D 9-poles RS232 connector
GREEN
LNA - DOW N L INK - communicates with
management unit
35
GREEN / RED LED
LNA DOW N
RED
LNA - DOW N - does not communicate with
management unit
GREEN
LNA - UP LINK - communicates with management
unit
36
GREEN / RED LED
LNA UP
RED
LNA - UP LINK - does not communicate with
management unit
GREEN
BS1 communicates with management unit
37
GREEN / RED LED
Band Selective 1
RED
BS1 does not communicate with management unit
38
Sub-D 15-pole management link between Down Link HPA and management unit
GREEN
BS2 communicates with management unit
39
GREEN / RED LED
Band Selective 2
RED
BS2 does not communicate with management unit
40
GREEN LED 132kHz: 132kHz (line amplifier management carrier) correctly operating
41
RED LED: Return Loss alarm
42
Sub-D 15-pole management link between Up Link HPA and management unit
43
Sub-D 15-pole management link between Up Link HPA and management unit
44
HPA Up Link input
45
HPA Up Link monitoring SMA connector
46
GSM modem RF output
47
HPA Up Link output
RED ON
Trying to connect to network
48
RED LED: modem
operation
BLINKING
RED
Modem correctly operating
49
GREEN LED: equipment correctly operating
50
GREEN LED: 5.5V available
51
RED LED: equipment fault
57 (*)
AC voltage ONLY circuit breaker
EXTERNAL ACCESS POINTS MAP
52
BTS side 7/16 RF connector
53
Equipment Grounding
54 (*)
AC voltage input (230Vac)
55
48Vdc input / external alarms Connector
56
MS side 7/16 RF connector
(*) 230VAC MODEL ONLY
P
HIGH POWER AMPLIFIER
IN
SPV BUS
OUT
UP LINK
LNA DOWN
132KHz
ALARM
+5V
RL
OPERATING
U
U
LNA
HPA
D
D
BS 1
BS 2
RS232
HIGH POWER AMPLIFIER
SPV BUS
DOWN LINK
P
IN
OUT
LNA UP
In
Out
Out
In
BAND-SELECTIVE 1
In
Out
In
Out
DOWN-LINK
UP-LINK
DOWN-LINK
UP-LINK
BAND-SELECTIVE 2
1
45
44
43
42
40 39
33
32
30
4
6
9 10
14 15
23
21
11
16
18
17
2
13
52
47
34
31
36
29
49
37
22
3
12
1710-1785MHz
1710-1785MHz
1805-1880MHz
1805-1880MHz
26
38
INTERNAL VIEW - MODULES ACCESS POINTS
BOTTOM VIEW - REPEATER CASE CLOSED
EXTERNAL ACCESS POINTS
POWER SUPPLY
5V5
10V5
50
28
27
51
41
35
25
24
5
46
48
55
56
Copyright protection according to law
ILL DCS OFF-AIR REPEATERS
Scale
Revisions
Title
2/2
Sheet
Date
Part Number
1800MHz ADJUSTABLE BAND OFF-AIR REPEATERS
MODULES ACCESS POINTS MAP AND EXTERNAL
ACCESS POINTS MAP
Drawn by
CG
AV
MN
Approved by
Checked by
57
0
ED. 02
31/01/2007
ED. 01-1
29/09/2006
53
54