HYBRIFLEX Power Splice 4AWG to 6AWG Instruction
Overview:
The following instructions detail how to splice the power cables inside the corrugated tube of the
jumpers and riser assemblies. This procedure applies to 4AWG and 6AWG connections.
Safety:
Caution! Use hand protection and safety glasses when splicing power cables.
Figure 1: Field Splice Kit Parts for PW-SPLICE-ST (78000832) & PW-SPLICE-ST-PT (78000833)
Heat Shrink Sleeve, 2” Dia. x 6.0” long (Qty 4)
Connector, Splice, 4AWG (Qty 2)
Heat Shrink Sleeve, 1” Dia. x 3.5” long (Qty 2)
Corrugated Conduit, 12.0” long (Qty 1)
Junction Box
Fitting
Rip Cord
Riser