If a user toggles switch 4 to the
DOWN
position, then fiber port # 2 will be set to half-
duplex. The factory default settings for fiber ports will be always
UP
position for full-
duplex.
Full-duplex
ettings for Fiber Half Duplex
DIPSwitch S
SW
Port
Down
Factory Settings
UP
2
4
Half duplex
Half duplex
Full duplex
Full duplex
Half-duplex
4
6
3.6
Powering the RFL 3000 4K24 Switch
RFL 3000 4K-Series Switches incorporate an internal universal power supply, and have a
recessed male IEC connector for the AC
ON
OFF
110-220
VAC
47-63Hz
1.0-0.5A
Figure 3.5: RFL 3000 4K24 AC power connector
power cord at the left-rear.
A manual AC power ON-OFF switch is adjacent. A six-foot 115 VAC 60 Hz
standard power cord is supplied with each unit shipped within North America.
For DC power options, see Appendices.
4.0 OPERATION
This chapter describes the functions and operation of the 4K-Series.
4.1 Switching
Functionality
RFL 3000 4K-Series units provide switched connectivity at Ethernet wire-speed
among all of its ports simultaneously. They support 10/100Mbs for copper media and
100Mb for fiber ports to maximize bandwidth utilization and network performance. All
ports can communicate to all other ports in a RFL 3000 4K-Series, but local segment
traffic on a port will not consume any of the bandwidth on any other port.
RFL 3000 4K-Series units are plug-and-play devices. There is no software
configuring to be done at installation or for maintenance. The only hardware
configuration settings are user options for UP-LINK on RJ-45 port. The internal
functions of both are described below.
Filtering and Forwarding
Each time a packet arrives on one of the switched ports, the decision is taken to
either filter or to forward the packet. Packets whose source and destination addresses are