RFI FSA10-67-DIN Installation Download Page 2

406-512 MHz

M-8570

FLAT SCREEN ASSEMBLY

M6 BOLT ASSEMBLY

SMD40-67

DIPOLE ASSEMBLY

SMALL CLAMP

PLATE

153 ±2 MM  (6")

SET DIPOLE

TOP VIEW

FSA10-67-DIN

ANTENNA ASSEMBLY

STEP 1:

ASSEMBLE DIPOLE TO FLAT SCREEN AS PICTURED BELOW ENSURING THE DIPOLE TO SCREEN SPACING IS
SET CORRECTLY AND THE DIPOLE DRAINHOLE IS FACING DOWNWARDS. USING THE M6 BOLT ASSEMBLY
AND SMALL CLAMP PLATE INCLUDED IN THE KIT. TIGHTEN M6 BOLTS TO 10NM (7 lbf.ft)

STEP 2:

FIT THE M12 STUDS TO THE ANTENNA ASSEMBLY AS PICTURED, TORQUE TO 55NM (40 lbf.ft) 

153 ±2 MM  (6")

SET DIPOLE

DRAIN HOLE

POSITION

INS-40079-1

©RF Industries Pty Ltd 2009

www.bird-technologies.com

PAGE 2 OF 4