Wiring in Power Lines
120VAC systems:
120VAC systems are prewired using a standard 110V plug with supplied
+13.5VDC adapter.
+12VDC Systems:
The +12V adapter cord can be used for +12V systems by simply cutting the
cord to length and wiring the lead with the
white
stripe to +12V and the
black
only lead to Ground. *Note– Optional power converter may be nec-
essary for non-standard voltage.
24VAC Systems:
Use special connectors; contact us at (724) 610-5256
General Information:
The radio remote control that you are installing can be used for most electrical
switching and control applications. Before beginning the installation
and testing you should check that each item listed below is available
and in good condition.
1. Antenna:
Magnetic mount antenna with 15ft of cable.
2. Receiver:
Usually pre-wired inside for most systems.
3. Transmitter:
Hand-held controller with pushbuttons.
4. Batteries:
(2) AA NiMH battery rechargeable for transmitter.
*****Batteries need charged prior to first use*****
Operator may use (2) AA alkaline batteries instead.
YellowJacket Pro System
Remote Control Installation/Setup
Maintenance Notes
The receiver box should be kept dry and should be periodically dusted off.
Check the transmitter’s batteries weekly. Only use two (2) AA alkaline or equivalent rechargeable
batteries. When the batteries are weak the Transmitter’s LED will light on red and off slowly and
you may notice some reduced operating range.
Clean the antenna periodically with mild soap and water; do not immerse in water. Allow to dry
completely before use.
If unit is to be returned for service, please clean the transmitter and the receiver before sending it
back. Visit www.rfhero.com/request-rma.php to issue an RMA for system maintenance.
1.
2.
3.
4.
For help with installation or service
Phone: (724) 610-5256
Web: www.rfhero.com
Email: [email protected]
Wiring In Control Lines
RFHero™ remote systems are wired to work with a variety of
insulation machines. To easily adapt to other makes and models, please use the provided UAX-
100 adapter cable and simply use the correct plug end for your machine. The most popular wiring
convention that many insulation machine manufactures use is:
Green
–
Common Voltage
White
–
Blower/Air
Black-
Material Feed
To utilize the UAX-100 simply use the following color code:
UAX-100
Green
Brown
Blue
Function
Common Voltage
Air/Blower
Material Feed
Machine Side
Green
White
Black