background image

Technical specifications

COFDM (DVB-T/DVB-T2)/QAM (DVB-C) INPUT

Number of channels

2

Tuners

2

Input frequency range

177,5 - 858 MHz

Input level

45 … 85 dBuV

Bandwidth

7 MHz or 8 MHz

FEC decoder

Automatic

CI slot

2

QAM OUTPUT

Modulation

QAM 32, 64, 128, 256

Output frequency range

114 MHz - 858 MHz

Symbol rate 

1-8 Msymb/s

Output level

85 - 105 dBuV

Data interface

2* USB 1

Input connectors

F-female 75 ohm

Output connectors

F-male 75 ohm

Power consumption

16VDC/1,2A

Dimensions 

W*H*D

72mm*218mm*129mm

Mounting

RFT-800 system or stand alone

RF-Tuote Oy, Joensuunkatu 13, 24100 Salo tel. +358-2736 6360, fax. +358-2-736 6355, [email protected], www.rf-tuote.fi    

Summary of Contents for RFT-855

Page 1: ...RFT 855 2 MUX DVB T T2 C COFDM HD remux modulator User Manual RF Tuote Oy Joensuunkatu 13 24100 Salo tel 358 2736 6360 fax 358 2 736 6355 info rf tuote fi www rf tuote fi...

Page 2: ...air passage holes Signals from antenna are fed to IEC connectors at the top of unit When RFT 855 is mounted for RFT 800 frame the power voltage is supplied through active output combiner RFC 808 or RF...

Page 3: ...SW version numbers plus unit serial number are shown When the unit is powered the display lights up showing selected output channels Fig 1 no 2 The factory set channels are E40 and E42 The display is...

Page 4: ...its 3 3 Set up To start set up press Menu key Fig 2 no 1 Main Menu will be displayed Select Configuration Following settings can be selected Audio Language recommended ALL NOTE When MPEG 4 programs ar...

Page 5: ...the wanted position number e g 02 The set top box set this program to memory place no 2 NOTE LCN setting works only in the set top boxes which support LCN function The LCN selection can be canceled by...

Page 6: ...in parenthesis on the same line Select DVB T Constellation QAM 64 Select appropriate FEC NOTE If outgoing bitrate is less than 50 of maximum select bigger FEC value e g 1 2 or 2 3 to reach bigger bit...

Page 7: ...Modulation QAM 32 64 128 256 Output frequency range 114 MHz 858 MHz Symbol rate 1 8 Msymb s Output level 85 105 dBuV Data interface 2 USB 1 Input connectors F female 75 ohm Output connectors F male 7...

Page 8: ...ot dispose of these products as unsorted municipal waste Fore more information about where you can drop off your waste equipment for recycling please contact your local city office your house disposal...