DS232-4 June ’04
©2004 Reg. No. 227 4001, ENGLAND
Page 11
RS232 R
ADIO
M
ODEM
232C-868FR1
R/W
S212
Parity
Indicates the parity on the serial link:
'1' -> No parity (default value)
'2' -> Even Parity
'3' -> Odd Parity
R/W
S213
Number of
Stop Bits
Number of Stop bits on the serial link:
'1' -> 1 Stop bit (default value)
'2' -> 2 Stop bits
R/W
S214
Time-out
Time-out in milliseconds on the serial link. Valid between 2 and 100
milliseconds.
Default value: 5 ms
R/W
S216
Flow Control Indicates the flow control mode:
‘0’ -> RTS/CTS
‘2’ -> None (Default value)
R/W
S218
Buffer size
Indicates the maximum size of frames. When this maximum size is
reached, the modem switches the CTS signal.
Valid between 30 and 245 bytes.
Default value: 245 bytes
Operation
Access Register
Name
Description
Indicates the operation mode of the modem.
'1'
->
Transparent (Default value)
'3' ->
Transparent
Secured
'6' ->
Master
I/O
'7' ->
Slave
I/O
'9' ->
Addressed
Secured
‘10’
->
Demo mode – master
R/W
S220
Operating
Mode
‘11’
->
Demo mode – slave
R/W
S221
Autorepeat
Indicates auto-repeat status in transparent mode (i.e. whether the
modem automatically replies a data frame)
’0’ -> Autorepeat off (Default value)
‘1’ -> Autorepeat on
R/W
S223
Number of
Retries
Indicates the maximum number of retries when a message contains
errors in secured mode. Valid between 0 and 255 (modulo 256). If the
value is ‘0’, frames are not checked and considered as good (used for
tests).
Default value: 2
Addressed Management
Access Register
Name
Description
R/W
S250
Network
Number
Indicates the network number using 2 bytes. Only
members of the same network can communicate
together. Valid between 0 and 65535 (modulo 65536), it is set to ‘0’
when the modem is not initialised.
NB: Setting S250 to ‘0’ also sets S252 to ‘0’.
Default value: 0