__________________________________________________________________
RF Technology PA70 Page 3
1 OPERATING INSTRUCTIONS
1
Operating Instructions
1.1
Front Panel Indicators
PWR LED
The Power LED shows that the dc supply is connected to the transmitter.
RFO LED
The RF Output LED indicates that the amplifier is being driven and that the
forward output power is above a present level. The indication level is set by
RV1 which is accessible through the side of the case. (After removing 20
screws)
TEMP LED
The Temperature LED indicates when the amplifier temperature is too high.
The power is automatically reduced if the output transistors temperature rises
above safe limits.
1.2
Internal Adjustments
All internal adjustments are factory set and should not need re-adjustment
unless the operating frequency is changed.
Output Power
The output power is set to the desired level watts by RV2. It determines the
threshold of the ALC voltage which is fed back to the transmitter module to
Warning
Changes or modifications not expressly approved by
RF Technology could void your authority to operate
this equipment. Specifications may vary from those
given in this document in accordance with requirements
of local authorities. RF Technology equipment is
subject to continual improvement and RF Technology
reserves the right to change performance and specifications
without further notice.