54
S12
GUARD
TIME
Sets the time in 20ms units required to separate the escape code sequence from other data.
S13
SYSTEM
ID
LSB
S14
SYSTEM
ID
MSB
Both bytes are transmitted and checked as part of every radio message.
S15
MIN POWER SAVE ADDRESS
S16
MAX POWER SAVED ADDRESS
All radios within the range max to min inclusive will operate in power saved mode. Any
commas with destination addresses in this range will start with a long wake up message.
S17
LINK ESTABLISHMENT TIME
This sets the time in 1 sec units that a calling radio will wait before reporting to its host that a
dial command has failed.
S18
CONNECTED INACTIVITY TIME
This time (in 1 sec units) is used as timeout for the following:
1/ receipt of a routing message following acknowledgement of a wake up call.
2/ receipt of a link establishment message from a down link radio when in relay
mode.
3/ receipt or transmission of data in transparent mode or relay mode.
Timeout results in the radio going back to idle mode (i.e. the link is cancelled).
S19
POWER SAVE ON TIME
The time in seconds for which the radio is asleep between checking for wake up signals.
S20
LONG WAKE UP SIGNAL DURATION
The time in seconds that the wake up message is sent to a power saved radio.
S21
OFF LINE INACTIVITY TIME
The time for which a radio will wait for its host to wake up after raising RI if auto answer is
disabled.
S22
not
implemented
S23
MY
ADDRESS
The radio's own network address.
S24
REPLY
TIME
The time in 10ms units that a radio waits for a reply to a wake up call.
S25
AWAKE
TIME