background image

TRAP Remote Controls 

DS

-

TRAP

-

10       Page  10 

 

Technical specifications 

Receiver Decoder: TRAP-Receiver 

Enclosure Rating: 

 

IP68   

Dimensions:   

 

130 x 112 x 42 mm (not including antenna) 

Operating Temperature:  

 

-10 to +50

Celsius. 

 

*The relay contacts in this unit are for functional use only and must not be used for isolation purposes 

Electrical Characteristics 

MIN 

TYPICAL 

MAX 

DIMENSION 

Supply Voltage  

  

32 

Vdc or ac 

Supply Voltage for 230Vac 

 

230 

 

Vac 

Relay Rating* (230Vac)  

  

12 

Supply Current at Vsupply 12V 

 

 

Quiescent 

 

 

All relays operating* 

  

 

15 

175 

  

  

mA 

Time delay from Tx on Switch to Rx Relay operation 

  

 26 

 

mS 

Time delay from Tx sw relax to Rx Relay release 

  

 26 

 

mS 

50.00

59

.0

0

46

.0

0

82.00

10

.0

0

All Dimensions in mm

Mechanical Dimensions  

76

80

4

20

96

100

Measurements in mm drawing not to scale

Summary of Contents for TRAP Series

Page 1: ...ck from Rx Continuous State change Transmit Receiver 6 32Vac dc Supply Waterproof Receiver IP68 Outputs Momentary or Latching Optional Rx Acknowledge back to Transmitter Optional External Antenna moun...

Page 2: ...smitter 868MHz Version 918MHz Version 1 Switch TRAP 8T1 TRAP 9T1 2 Switch TRAP 8T2 TRAP 9T2 4 Switch TRAP 8T4 TRAP 9T4 16 Switch 8Sw Shift Key TRAP 8T16 TRAP 9T16 Description Receiver Power Supply 868...

Page 3: ...transmitter to switch the outputs 6 Change the output functions to latching Momentary Operation Relay Relay Relay 0V LOAD 12V 12V 0V COM NO NC Supply Terminals TRAP RX Relay COM NC NO Live in Switched...

Page 4: ...itions Switch relays LK1 LK2 RLY 1 RLY 2 RLY 3 RLY 4 Open Open 1 2 sec Mom 1 2 sec Mom 1 2 sec Mom 1 2 sec Mom Closed Open Mom Mom Latch Latch Open Closed Mom Mom Mom Mom Closed Closed Latch Latch Lat...

Page 5: ...eed to indicate that an acknowledgment has not been received back form the receiver Low Battery Low Battery LED illuminates for 3 seconds after each operation Low Battery RF Acknowledge From Receiver...

Page 6: ...ck from the receiver Whilst in theory if an RF signal can be transmitted one way then it can be returned in practice occasionally the received acknowledgement many not penetrate as well as the transmi...

Page 7: ...t 1 To select relay output 2 3 o 4 briefly place the trans mitter again so that the Buzzer Buzzes to indicate the Relay output 2 3 or 4 4 Press the switch on the transmitter which you wish to pair 5 T...

Page 8: ...Wall mount antenna 3m cable Wall Mount Whip Antenna Active gain 5dB RG58 Connecting Lead SMA Connector CBA UFLSMA Push fits onto the External antenna Connector and provides a panel mount SMA connecto...

Page 9: ...Dimensions 90 x 54 x 27 mm Changing the Battery Remove the six enclosure screws Remove 2 battery compartment screws and re place batteries taking care of cables and battery polarity 25 92 6 17 Mechani...

Page 10: ...used for isolation purposes Electrical Characteristics MIN TYPICAL MAX DIMENSION Supply Voltage 6 32 Vdc or ac Supply Voltage for 230Vac 230 Vac Relay Rating 230Vac 5 12 A Supply Current at Vsupply 12...

Page 11: ...rried along the beacon whilst being repeatedly operated At full distance the Transmitter was also tested while placed on the ground The transmitter was operated for long and short bursts 3 2KM range w...

Page 12: ...e following internet address www rfsolutions co uk ES Por la presente RF Solutions Limited declara que el tipo de equipo radioel ctrico definido dentro de este documento es conforme con la Directiva 2...

Reviews: