background image

HORNETPRO Remote Control System 

NOTE: Installation should be carried out by a qualified technician 

Getting Set Up: 

 

Unscrew the 2 screws at the base. 

 

Remove base panel. 

 

Unscrew the antenna at top of enclosure.  

 

Lightly pull the PCB inside to remove.  

Relay

Relay

Relay

0

V

LO

A

D

1

2

V

12V

0V

COM

NO

NC

Supply 

Terminals

TRAP-RX

Below is a simple example showing one possible way to wire a relay in order to give 
switched power to an external load: 

When the relay is energised the ‘COM’ connects to ’NO’ and power is applied 

to the Load. 

NOTE: For full installation instructions and product specification, please see the  
HORNETPRO Datasheet at www.rfsolutions.co.uk. 

HORNETPRO Remote Control System 

NOTE: Systems come pre-paired. Pairing instructions only need to 
be followed for additional transmitters.  

With this system, you can pair together any individual transmitter 
switch, with a receiver relay output switch. Without opening either             
enclosure... 

1.  Briefly (for less than 1 second) place a magnet next to the 

top left of the receiver as shown,  and then remove it. 

2.  The receiver will buzz once (One buzz means the receiver unit 

is ready to allocate a transmitter to relay switch 1). 

3.  Press the switch on the transmitter which you wish to pair. 

4.  The receiver will buzz twice to confirm pairing. 

5.  Repeat for any additional transmitter switches. 

NOTE: Each receiver has a maximum memory for up to 28 pairings, 
these can be from any switches on any transmitters! 
To select relay outputs 2,2,4, repeat step 3 above and count the 
number of buzzes.  2 buzzes for relay 2,  3 for 3 etc.  

 

Advanced operation - Pairing a transmitter button 

Setting the Outputs Momentary or Latching Operation 

1

/

2

 sec Mom  = Relay will operate for 

1

/

2

 sec  

Mom  

= Relay will operate for as long as          

 

 

 

   transmitter switch operated 

Latch   

= Relay will toggle ON/OFF on each      

 

 

 

   transmitter button press 

Link Positions 

Switch relays 

LK1 

LK2 

RLY 1 

RLY 2 

RLY 3 

RLY 4 

Open 

Open 

1

/

2

 sec Mom 

1

/

2

 sec Mom 

1

/

2

 sec Mom 

1

/

2

 sec Mom 

Closed 

Open 

Mom 

Mom 

Latch 

Latch 

Open 

Closed 

Mom 

Mom 

Mom 

Mom 

Closed 

Closed 

Latch 

Latch 

Latch 

Latch 

NOTE: If link setting is changed, power cycle the receiver (turn off/on) otherwise it will stay in 
the same mode it was previously set in.  

Reviews: