Pairing Transmitters to the HORNET-RX (12-32Vdc Version) 
 

 
Please note that the HORNET Systems are provided ready to operate and Pairing a 

transmitter to a receiver is only required when replacing or adding a new transmitter. 
 
 
To pair a new transmitter switch follow this procedure 
Note!: Any transmitter button can be configured to operate any of the receiver relays. 
 
1.  Select the receiver output relay to learn to: 
2.  Briefly press the receiver Pairing switch (S2) once 
3.  The Learn LED will flash once to indicate relay 1 is selected 
4.  After the LED stops flashing, press the Learn switch again to select the next                   
relay channel 
5.  Repeat step 4 until the required relay is selected. 
6.  Press the button on the transmitter you want to learn to the chosen relay. 
7.  The Learn LED will flash to indicate Pairing is complete.     
 
Pairing a Transmitter to a Receiver 
Each  receiver  has  a  maximum  memory  for  up  to  30  pairings,  these  can  be  from  the 

same or any number of transmitters. 
 
Erasing Receivers Memory  
1.  Press and hold the receiver Learn Switch for approx 10 seconds.  
2.  When the Learn LED turns ON all memory is erased 
NOTE: You cannot erase individual Tx encoders  

 

 

Summary of Contents for Hornet-S1

Page 1: ...variety of switching appli cations Transmitters may be added using the learn process any button on the transmitter can be used to control one or many outputs of the receiver Features Up to 100metres Range 4 Changeover Relays 12 30Vdc or 230Vac versions Reliable FM Technology Each output Rated 1000W Waterproof Enclosure to IP68 Momentary or Latching Relays Any Switch Map to Any Relay Output CE FCC ...

Page 2: ... System 3 channel 433 92 100 HORNET RX Receiver 4 channel 433 92 Part Number Description Frequency MHz Range Metres HORNET S1M System 1 channel 433 92 100 HORNET S2M System 2 channel 433 92 100 HORNET RXM Receiver 2 channel 433 92 Bespoke Versions Custom versions available with your own logo and or protocol Please contact Sales for further info Range stated is optimum direct line of sight In worst...

Page 3: ...2 The circuit board will then slide out 3 Connect to the screw terminals Live in Switched live out Pairing button Momentary latching settings link 1 2 Relay4 Relay3 Relay2 V 0V HORNET 12 32V Systems COM NO NC NO COM NC NO COM NC NO COM NC Power In 12 32Vac or dc GND Rx LED Learn LED Configuring Output Relays Momentary or Latching These are set by the Jumper Links Momentary operates as long as tran...

Page 4: ...nce 3 The Learn LED will flash once to indicate relay 1 is selected 4 After the LED stops flashing press the Learn switch again to select the next relay channel 5 Repeat step 4 until the required relay is selected 6 Press the button on the transmitter you want to learn to the chosen relay 7 The Learn LED will flash to indicate Pairing is complete Pairing a Transmitter to a Receiver Each receiver h...

Page 5: ...by removing the antenna and fixing screws from the base 2 The circuit board will then slide out 3 Connect to the screw terminals Warning The Receiver unit is designed to be a fixed installation connected to a mains supply Before removing the cover ensure that the mains input supply is removed Any opera tion of the product that involves removal of the cover should only be carried out by a Relay COM...

Page 6: ...Switch the receiver unit OFF and then ON again in 1sec intervals SIX times finally leaving the unit powered 3 The receiver emits a continuous Click to confirm it is now in learn Mode 4 Press the chosen transmitter button 5 The receiver will acknowledge by sounding the two buzzes 6 Learn Process complete Erasing Receivers Memory 1 Power the receiver unit up and wait 10 seconds for the unit to enter...

Page 7: ... used for isolation purposes ELECTRICAL CHARACTERISTICS Min Typical Max Units Supply Voltage for 12 30V versions 10 5 12 30 Vdc Supply Voltage for Mains versions 230 Vac Relay Rating 230Vac RLY1 4 5 rms 12 peak A Supply Current Quiescent 12V All relays operating 10 140 mA Supply Current 230V 13 mA Time delay from Tx on Switch to Rx Relay opera tion 100 mS Time delay from Tx sw relax to Rx Relay re...

Page 8: ...F Solutions Limited et käesolev raadioseadme tüüp määratletud selles dokumendis vastab direktiivi 2014 53 EL nõuetele ELi vastavusdeklaratsiooni täielik tekst on kättesaadav järgmisel internetiaadressil www rfsolutions co uk FI RF Solutions Limited vakuuttaa että radiolaitetyyppi määratletud selles dokumendis on direktiivin 2014 53 EU mukainen EU vaatimustenmukaisuusvakuutuksen täysimittainen teks...

Reviews: