ELITE Low Voltage / Dry Contact Remote control System
ELITE Low Voltage / Dry Contact Remote control System
ELITE Low Voltage / Dry Contact Remote control System
ELITE Low Voltage / Dry Contact Remote control System
DS-ELITE-L-3 PAGE 6
0 LED
1 LED
2 LED
3 LED
4 LED
5 LED
6 LED
7 LED
8 LED
0s
½ s
5s
10s
30s
1m
10m
30m
1hr
Advanced operation continued…
TEST MODE
The ELITE comes with an in-built test mode which allows a user to check the signal strength of any
compatible handheld:
1.
Press the TEST button on the PCB (see page 3 for button locations)
2.
Press any button/activate the transmitter which you want to test
3.
LEDs 1-8 will show a bar graph of the signal strength - the more LEDs flashing, the better the signal.
4.
To exit test mode - press test again.
Notes
:
- When in test mode the receiver still operates relays as normal.
- For reliable communications please ensure at least 3 LED’s are lit.
- Try the transmitter in the location where it will be used to make sure it will work once
installation complete.
TIMER SELECT MODE
Note:
As default all timers are set to 0 seconds.
The ELITE has a timer option which can be set individually on each output. Meaning that you can set any
output to de-activate after a different amount of time should you wish to.
1.
To enter timer select mode - Press the TIMER button
2.
Select your chosen output by pressing the TIMER button to scroll through each relay in turn
3.
As soon as the LED for the required output stops flashing tap the TIMER button again
4.
Each tap of the timer button will increase the timer delay in line with the table below
5.
When you have selected the required delay stop tapping and, wait 3 seconds.
6.
The Red TIMER LED will flash to show that the setting is saved
Note:
Settings are saved even after power is removed.
NOTE:
When zero LED’s are lit the relays will operate as per the Momentary/latching links.
TIMERS and MOMENTARY/LATCHING setting links
1.
When the momentary/latching setting link for a relay is set to MOMENTARY the timer will restart its
count down every time a button is pressed.
2.
When the momentary/latching setting link for a relay is set to LATCHING, the relay will turn ON/OFF
with each button press. If the relay is left ON it will turn off after the timer period expires.
Erasing ALL Timers:
1.
Open the case and apply power
2.
Press and hold the TIMER button for 10 seconds,
3.
A single relay LED will be flashing
4.
When all Relay LED flash together and then go out the timer erase process is complete.
5.
All relays will operate as per their jumper settings.