background image

RF-LAMBDA

The power beyond expectations

RF-LAMBDA INC.            www.rflambda.com   

Sales: [email protected]       Technical : [email protected]

REMC34G36GD

25

Wi

de 
Band S

ol

id 

St

at

EMC
-Benc

ht

op
Pow
er

 A

mpl
ifi

er

 34

-36GHz 

25W Solid State EMC Benchtop Power Amplifier  

34GHz~36GHz

Features

Automatic Calibration

Built in Temperature Compensation

Adjustable Attenuation: 
31.5dB Range, 0.5dB Step Size

Supply Voltage: 110V/220V AC 

Typical Applications

Aerospace and military applications

Test and Measurement.

Research and Development.

Parameter

Min.

Typ.

Max.

Units

Frequency Range

34 - 36

GHz

Gain

50

dB

Gain Variation Over Temperature

(-45  ~  +85)

-

dB

Input Return Loss

-

dB

Output Return Loss

-

dB

Saturated Output Power (Psat)

44

dBm

Output Third Order Intercept (IP3)

-

dBm

Isolation S12 

-

dB

Input Max Power (No Damage)

Psat – Gain 

dBm

Weight 

35

lbs

Impedance

50

Ohms

Power Supply Connector

D-SUB COMBO 3POS

Input / Output Connectors

Input: 2.9mm female, Output: 2.92mm female or WR28

Material 

Aluminum / Copper

Electrical Specifications, T

A

=25

Summary of Contents for REMC34G36GD

Page 1: ...0V 220V AC Typical Applications Aerospace and military applications Test and Measurement Research and Development Parameter Min Typ Max Units Frequency Range 34 36 GHz Gain 50 dB Gain Variation Over T...

Page 2: ...Connect input and output with 50 Ohm source load in band VSWR 1 9 1 or 10dB return loss Step 2 Turn on AC power Step 3 Enable RF output Power OFF Procedure Step 1 Turn off RF output power Step 2 Turn...

Page 3: ...However operation with poor loads is discouraged If prolonged operation with poor or unknown loads is expected an external device such as an isolator or circulator should be used to protect the ampli...

Page 4: ...soever for any of the information contained herein RF Lambda assumes no responsibility or liability whatsoever for the use of the information contained herein The information contained herein is provi...

Page 5: ...mplifier 34 36GHz Power Indicator Gain Adjustment Knob ON OFF switch Instrument AC power supply switch USER CONTROL D SUB Connector low voltage 3 3V TTL control signals See page below for more informa...

Page 6: ...light up To eliminate the error code press RESET on front panel keypad to reboot the instrument and clear the alarms If error code can not be eliminated after reboot please contact support rflambda c...

Page 7: ...trument Function Selection Page Instrument Status Display Page To enter this function selection page press Menu on front panel keypad while the instrument is showing the status page Press the correspo...

Page 8: ...hen amplifier is driven over temperature Yes 6 Current Over Indicator LOW Pin will be latched to logic HIGH when drain current limit is reached Yes 7 ID Imbalance Indicator LOW Pin will be latched to...

Reviews: