25

Wi

de 
Ba

nd 

So

lid Sta

te

 EMC
-Be

nchto
p P
ower

 A

mp
lifi

er

 26

.5

-3

4GHz 

ALARM

POWER

RF INPUT

ON

RF OUTPUT

WR 28

ADJUST

PN:REMC27G34GB
Freq:27-34GHz

THE LEADER OF RF BROADBAND SOLUTIONS

OFF

9

8

7

6

5

4

3

2

1

0

.

BACK-
SPACE

RESET

MENU

?

ENTER

?

?

?

436.8 [17.197]

4

4

7

 [1

7

.598

]

5

7

.2

 [

2

.252

]

3

.5 [0.

1

3

8

]

7.5 [0.295]

5

0

6

.94 

[1

9

.9

5

8

]

1

4

.5

 [

0

.571

]

448.8 [17.669]

1

3

3

.2 [5.

2

4

4

]

1

4

7

.2 [5.

7

9

5

]

482.6 [19.000]

2

2

.1

7

 [0

.8

7

3

]

1

3

3

.2 [5.

2

4

4

]

491.44 [19.348]

436.8 [17.197]

1

0

9

.2 [4.

2

9

9

]

412.8 [16.252]

Important Notice

Outline Drawing: 

All Dimensions in mm [inches]

The information contained herein is believed to be reliable. RF-Lambda makes no warranties regarding the information contained herein.
RF-Lambda assumes no responsibility or liability whatsoever for any of the information contained herein. RF-Lambda assumes no responsibility
or liability whatsoever for the use of the information contained herein. The information contained herein is provided "AS IS, WHERE IS" and
with all faults, and the entire risk associated with such information is entirely with the user. All information contained herein is subject to
change without notice. Customers should obtain and verify the latest relevant information before placing orders for RF-Lambda products. The
information contained herein or any use of such information does not grant, explicitly or implicitly, to any party any patent rights, licenses, or
any other intellectual property rights, whether with regard to such information itself or anything described by such information.
RF-Lambda products are not warranted or authorized for use as critical components in medical, life-saving, or life sustaining applications, or
other applications where a failure would reasonably be expected to cause severe personal injury or death.

Summary of Contents for REMC27G34GB

Page 1: ...110V 220V AC Typical Applications Aerospace and military applications Test and Measurement Research and Development Parameter Min Typ Max Min Typ Max Units Frequency Range 26 2 30 31 34 GHz Gain 70 50...

Page 2: ...re Step 1 Connect input and output with 50 Ohm source load in band VSWR 1 9 1 or 10dB return loss Step 2 Turn on AC power Step 3 Enable RF output Power OFF Procedure Step 1 Turn off RF output power St...

Page 3: ...damage However operation with poor loads is discouraged If prolonged operation with poor or unknown loads is expected an external device such as an isolator or circulator should be used to protect th...

Page 4: ...ales rflambda com Technical support rflambda com Rev 1 01 28 19 REMC27G34GB 25W Wide Band Solid State EMC Benchtop Power Amplifier 26 5 34GHz Small Signal S Parameters Note Input output return loss me...

Page 5: ...NC www rflambda com Sales sales rflambda com Technical support rflambda com Rev 1 01 28 19 REMC27G34GB 25W Wide Band Solid State EMC Benchtop Power Amplifier 26 5 34GHz Gain vs Output Power 27GHz 31GH...

Page 6: ...Technical support rflambda com Rev 1 01 28 19 REMC27G34GB 25W Wide Band Solid State EMC Benchtop Power Amplifier 26 5 34GHz Left IM3 vs Pout 27GHz 31GHz Left IM3 vs Pout 32GHz 34GHz Memory Effect 27G...

Page 7: ...lity whatsoever for any of the information contained herein RF Lambda assumes no responsibility or liability whatsoever for the use of the information contained herein The information contained herein...

Page 8: ...Power Amplifier 26 5 34GHz Power Indicator Gain Adjustment Knob ON OFF switch Instrument AC power supply switch USER CONTROL D SUB Connector low voltage 3 3V TTL control signals See page below for mor...

Page 9: ...ator will light up To eliminate the error code press RESET on front panel keypad to reboot the instrument and clear the alarms If error code can not be eliminated after reboot please contact support r...

Page 10: ...menu Instrument Function Selection Page Instrument Status Display Page To enter this function selection page press Menu on front panel keypad while the instrument is showing the status page Press the...

Page 11: ...c HIGH when amplifier is driven over temperature Yes 6 Current Over Indicator LOW Pin will be latched to logic HIGH when drain current limit is reached Yes 7 ID Imbalance Indicator LOW Pin will be lat...