REMC06G12GD

10

0W 

Wi

de Ban

So

lid 

St

at

EMC
-Benc

ht

op 
Pow
er

 Ampl

ifi

er

 6

-12

GHz 

Instrument temperature
RF output attenuation (change with adjustment knob)

RF input signal center frequency
Instrument RF output power

Switches On or Off for instrument RF output port

Indicates instrument RF output status. It will display:
Output is Ready to Turn on or RF Output is ON

Press “Menu” on keypad to enter instrument functions 
selection menu

Instrument Function Selection Page

Instrument Status Display Page

To enter this function selection page, press “Menu” on front 
panel keypad while the instrument is showing the status page.

Press the corresponding number on front panel keypad to 
select:

[1] Calibrate

” calibrates the instruments. 

[2] Frequency

” enters RF input signal center frequency. 

[3] RF ON/OFF

” switches the RF output port on or off.

[4] Reset

” Restarts the instrument (Turns RF output off)

[5] Status

” enters instrument status display page.

[6] Product Info

” displays product part number and serial 

number

All action functions will ask for confirming execution when selected from function selection menu.

User can set a constant gain for the unit. Equipment will 
automatically adjust the gain at certain frequency

Summary of Contents for REMC06G12GD

Page 1: ...erospace and military applications Test and Measurement Research and Development Parameter Min Typ Max Min Typ Max Units Frequency Range 6 10 10 12 GHz Gain 72 67 dB Gain Flatness 6 6 dB Gain Variatio...

Page 2: ...Connect input and output with 50 Ohm source load in band VSWR 1 9 1 or 10dB return loss Step 2 Turn on AC power Step 3 Enable RF output Power OFF Procedure Step 1 Turn off RF output power Step 2 Turn...

Page 3: ...However operation with poor loads is discouraged If prolonged operation with poor or unknown loads is expected an external device such as an isolator or circulator should be used to protect the ampli...

Page 4: ...Sales sales rflambda com Technical support rflambda com REMC06G12GD 100W Wide Band Solid State EMC Benchtop Power Amplifier 6 12GHz Gain Gain vs Output Power P7dB vs Frequency 2nd Harmonic Wave Outpu...

Page 5: ...soever for any of the information contained herein RF Lambda assumes no responsibility or liability whatsoever for the use of the information contained herein The information contained herein is provi...

Page 6: ...Amplifier 6 12GHz Power Indicator Gain Adjustment Knob ON OFF switch Instrument AC power supply switch USER CONTROL D SUB Connector low voltage 3 3V TTL control signals See page below for more informa...

Page 7: ...light up To eliminate the error code press RESET on front panel keypad to reboot the instrument and clear the alarms If error code can not be eliminated after reboot please contact support rflambda c...

Page 8: ...trument Function Selection Page Instrument Status Display Page To enter this function selection page press Menu on front panel keypad while the instrument is showing the status page Press the correspo...

Page 9: ...hen amplifier is driven over temperature Yes 6 Current Over Indicator LOW Pin will be latched to logic HIGH when drain current limit is reached Yes 7 ID Imbalance Indicator LOW Pin will be latched to...

Reviews: