Reznor EBHB Instructions & Installation Download Page 2

THE INSTALLATION MUST BE EXECUTED

BY A QUALIFIED TECHNICIAN

RISK OF ELECTROCUTION

IMPORTANT INSTRUCTIONS

When using electrical appliances, basic precautions 

should always be taken to reduce the risk of fi re, 

electric shock, and injury, including the following: 

Read all instructions before using this heater.

- A heater has hot and arcing or sparking parts inside. 
  Do not use it in areas where gasoline, paint, or fl ammable  

liquids are used or stored.

- This heater is hot when in use. To avoid burns, do not let bare 

skin touch hot surfaces. Keep combustible materials, like 
furniture, pillows, bedding, papers, clothes, and curtains away 
from heater.

- To prevent a possible fi re, do not block air intakes or exhaust in 

any way whatsoever.

- Do not insert or allow foreign objects to enter any ventilation or 

exhaust opening as this may cause an electric shock or fi re, or 
damage the heater.

- Do not install heater against combustible low-density cellulose 

fi berboard surfaces.

- Do not use outdoors.
- CAUTION - High Temperature; Keep electrical cords, drapes, 

and other furnishings away from heater.

- Use only with copper branch circuit conductors.
- For bathroom use, the heater must be installed so that switches 

and other controls cannot be touched by anyone in the bath or 
shower.

- Do not install this heating appliance beneath a wall outlet.
- To avoid possible electrical shock, disconnect all power at the 

main panel prior to wiring, cleaning, or servicing.

KEEP THESE INSTRUCTIONS.

INS338-201204-01

FURNITURE AND DRAPES

For maximum satisfaction an air fl ow of  3 in. (76.2 mm)
clearance is recommended.  Also allow 1 in. (25.4 mm) clearance 
on top and bottom of drapes when drapes cover wall.

INSTALLATION INSTRUCTIONS

1- Remove wire holder (or knock-out) of the appropriate junction 

box.

2- Make connection according to local and national codes and 

replace wire holder. (Do not forget ground wire.)

3- Install the relay or thermostat by removing front panel and 

junction box cover.

4- Check wire connection at the other junction box.
5- Fasten the baseboard to the wall using wood screws, tighten 

then release 1/2 turn.

6- Replace all covers before energizing.

INTERCONNECTION

The connection boxes and wiring channel are approved for inter-
connection of baseboard heaters and components which are on the 
same heating branch circuit. Use ‘‘BX’’ cable to run wiring for 
all other options in this series. (Ex: Corner box, empty cabinets, 
etc.).The heater junction box minimum volume without options is 
31.2 in³ (512 cm³).

CORNERS AND BLANK SECTIONS

Install blank sections and corners the same way as heating unit of 
this series. Use ‘‘BX’’cable to run wiring into these options. 

OPTIONS 

All heating equipment and options must be installed in accordance 
with local and national codes.

Built-in thermostat:

CAUTION:

 

The thermostat should not be considered as an 

infallible system where maintaining a temperature is considered 
critical. Examples:  Hazardous material storage, computer room, 
etc. In these particular cases, it is imperative to add a monitoring 
system to avoid the consequences of a failure of the thermostat.
-  Refer to wiring diagram for connections.
-  Refer to instructions supplied with the option for mounting.

Built-in relay:

-  Refer to the diagram included with the relay option 
 for 

connections.

-  Refer to instructions supplied with the option for mounting.

MAINTENANCE

- Once a year or at the need, remove the front panel and use a 

vacuum cleaner to remove the dust accumulation inside the 
heater. 

- Cleaning should be done while the heater is disconnected  

from the main service panel. Wait until the housing and heating 
element cool before performing maintenance. 

  Remove the front panel.
  CAUTION: Fins on the element are sharp - Do not touch. 
  Replace all covers before energizing.
- Any other servicing should be performed by a qualifi ed 

technician.

WARRANTY

The manufacturer warrants the electric heating element of 
this product for life. The other component parts are warranted 
against defects in material and workmanship for a one year 
period following the date of purchase, under normal use and 
maintenance, provided that there is a proof of purchase to confi rm 
this date. The obligation of the manufacturer, under the terms of 
this warranty, is limited to replacing the unit (baseboard heater 
only) and excludes all other costs related to the installation or 
replacement of the unit or spare parts.

WIRING DIAGRAM

High-Limit

High-Limit

Heating

Element

Heating

Element

Thermostat

1/2’’ (12.7 mm)

6’’ (152.7 mm)

CAUTION

DRAPES

3’’

76.2 mm

1’’ minimum

25.4 mm minimum

Reznor LLC

O’Fallon MO USA 63368

Tel.: 1 800 695-1901

www.ReznorHVAC.com

© 2014 Reznor, LLC. All rights reserved. All other trademarks

are the property of their respective organizations.

INSTRUCTIONS INSTALLATION

 

EBHB Model