11
The height of the building will be displayed on the main
line of the screen together with the three previous
measurements.
Device memory:
Press and hold the save button to display the last 20
measurements stored in the device memory.
All stored measurements can be deleted by pressing the
save button again.
REPAIR WORKS
Any defects should be fixed by a repair shop certified by
the manufacturer.
Powered products should not be thrown
away along with other household waste, but
disposed
by
specialized
companies.
Information on disposal shall be provided by the seller or
local authorities. Worn out electrical and electronic
equipment includes substances which are not indifferent
to the natural environment. The equipment other than
recycled is a possible threat to the environment and
human health.
5. TECHNICAL SPECIFICATION
RE-06-020
RE-06-021
Measurement range
0.05 ÷ 40m
0.05 ÷ 60m
Measurement accuracy
± 1.5mm
± 1.5mm
Measurement units
m / inch / ft
m / inch / ft
Laser type
Class II, 635 nm, <1mW
Class II, 635 nm, <1mW
Area and volume measurement
V
V
Pythagorean theorem
V
V
Addition / Subtraction
V
V
Max / Min distance
V
V
Continuous measurement
V
V
Backlight
V
V
Displaying of many measurement results
V
V
Tone signal
V
V
Water-resistant device
V
V
Device memory
20
20
Beam diameter
8 / 40mm
8 / 40mm
Position localizing
(10 / 60m)
(10 / 60m)
Operating temperature
-10
°
C do 50
°
C
-10
°
C do 50
°
C
Storage temperature
-25
°
C do 70
°
C
-25
°
C do 70
°
C
Working time on one charge
5000 measurement
5000 measurement
Power supply
2x1.5V AAA
2x1.5V AAA
Laser automatic switch-off
10s
10s
Device automatic switch-off
480s
480s
Dimensions
120 x 54 x 29mm
120 x 54 x 29mm
Weight
100g
100g
6. ISSUES SOLVING
Error code
Reason
Solution
Calculation error
Try again
The received signal is too weak, the
measuring time is too long, the
distance exceeds the maximum
range.
Reduce the distance, and try
again.
Device error
Turn the device off and on again.
If the error still exists, contact the
client service.