Rexroth IndraDrive FCS01.1
Parameterization
11-1
DOK-INDRV*--FCS01*****-IB01_EN-P
11 Parameterization
There exist four parameter records. During operation, it is possible to
switch between them. All parameters are visible in factory setting but can
be partially hidden with parameter P003. All parameters can be changed
"online".
Note:
As there are dependencies among the parameters, temporary
invalidity of data and thus malfunctioning may occur. For this
reason, only the inactive parameter record or non-critical
settings should be edited during operation.
The individual parameters are classified in different groups. The first digit of
the parameter number identifies the classification with one
menu group
:
Menu group
no.
Main function
Status indication
(P0--):
Used to select the physical unit of the
indication value.
Basic parameters
(P1--):
Comprise basic settings of the frequency
converter, e.g. activation and deactivation
behavior; together with the motor data,
they are sufficient for standard
applications.
Motor
/ characteristics parameters
(P2--):
Setting of motor-specific data; important
for ISD current regulation and selection of
the characteristic, as well as the setting of
dynamic and static boost.
Control terminals
(P4--):
Scaling of the analog inputs and outputs,
definition of the function of the digital
inputs and relay outputs, as well as PID
control parameters.
Additional parameters
(P5--):
These are functions concerning the
interface, pulse frequency, or error
confirmation.
Information
(P7--):
For indicating for example current
operating values, old error messages,
device status messages, or the software
version.
Array parameters -
01
...
-xx
Some parameters can additionally be
programmed or read out in several levels
(arrays). After selecting the parameter,
the array level must be selected
additionally.
Fig. 11-1:
Groups
Note:
Via parameter P523, the factory setting of all parameters can
be loaded at any time. This may for example be helpful when
commissioning a frequency converter whose parameters no
longer confirm with the factory settings.
Summary of Contents for IndraDrive Fc FCS01
Page 28: ...5 2 Delivery Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 34: ...6 6 Certifications and Types Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 56: ...8 20 Installation Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 88: ...10 4 Commissioning Rexroth IndraDrive FCS01 1 DOK INDRV FCS01 IB01_EN P ...
Page 237: ......