Step 6: Operating mode number 2 requires the relay
to be manually released.
Figure 16 – Set relay release point (Hysteresis)
MAINTENANCE
Periodically check oil level in V-Class drive when it
is stopped, at ambient temperature and has been shut
down for a minimum of 20 minutes. Add oil if
needed. If oil level is above the high oil level mark
on dipstick, lower the oil level to dipstick mark and
have the oil analyzed for water content and other
contaminants.
Follow maintenance instructions provided in manuals
178-052 & 288-400. When draining the V-Class
reducer, the oil in the clutch housing must also be
drained by removing the drain plug at the bottom of
the housing as shown below.
Figure 17 – Oil drain locations