![Rexnord 1874 Engineering Manual Download Page 31](http://html1.mh-extra.com/html/rexnord/1874/1874_engineering-manual_1449455031.webp)
ROUND BORE SPROCKETS
Figure 37
Figure 38
SQUARE AND HEX BORE SPROCKETS
Use round bore sprockets on conveyors
operating at room temperature. When
installing the sprockets, make sure that all
sprocket faces are positioned the same way
on the shaft, with identification marks all
facing the same direction, as shown above.
After positioning all sprockets in line with
sprocket tooth pockets in the chain, secure
the sprockets with set screws. (Also see
general note below).
Use square or hex bore sprockets on
conveyors intended for use at elevated or
lower temperatures (warmers, pasteurizers,
coolers, etc.). When installing the sprockets
make sure that all sprocket faces are
positioned the same way on the shaft, with
identification marks all facing the same
direction , as shown. Also, be sure to align
the notched teeth for proper timing.
GENERAL NOTE: It is generally recommended to lock center sprocket(s) to shaft
using set screws or set collars. The other sprockets should be allowed to "float" axially.
SELECTION
PROCEDURE
cont.
Sprocket
Installation
Re