Configuration
M200 Mk2
9
Setup #3 – IR-Address
Function
:
IR Address
Display
:
Remote Address
Connection
:
-
M219:
Yes
þ
The relay and dimmer functions
can be controlled through the
remote control and/or a con-
nected M218 wall-mounted op-
erating panel.
Through the selection of the
(RC5-) remote address, you can
define whether the relay and
dimmer functions should be
operated from the remote con-
trol and the wall-mounted opera-
tor panel or whether only one of
them should be accepted.
Address
Transmitter
Light (30)
Remote control
Local (19)
Wall mounted
remote control
Both (30+19)
Combination
i
The remote address has no rela-
tionship to the slot address,
which the M200 uses to register
with the M51/ M219.
Setup #3 – Source
Function
:
IR receiver
Display
:
Remote Source
Connection
:
inc. IR-Link - page 5
M219:
No
o
Selection of the (IR) sources
that the M200 interface accepts
for dimming and relay functions
as data suppliers.
This M-200 only
Accepts only sources that are
directly connected to the M200’s
IR Link, e.g..
MR204
or
M218
wall-mounted remote control.
All Receivers
All sources are accepted as data
suppliers, e.g. also a M51 or an
additional M200 interface.
This setting has no effect in the
case of a side room installation