background image

 

Dominating Entertainment. 

Revox of Switzerland

   

 

 

            

 E

 2.10_m1 

 

Re:connect 

M200  Mk2 

 
 

Domotic Interface 

Loewe

 

 

Summary of Contents for Re:connect M200 Mk2

Page 1: ...o Dominating Entertainment Revox of Switzerland E 2 10_m1 Re connect M200 Mk2 Domotic Interface Loewe ...

Page 2: ......

Page 3: ...200 Mk2 If you have an M200 Mk1 with the Atmega 163 16 processor you can upgrade this to the current Mk2 version with the Upgrade Kit After updating the M209 firmware to version 2 00 or higher we rec ommend completely resetting the M200 interface by pressing the Dis able softkey on setup page 5 for several seconds until setup page 1 automatically appears Please refer also to page 13 ff ...

Page 4: ...TV with M51 Loewe TV with M219 Gefen HDMI Switcher with M51 Gefen HDMI Switcher with M219 Overview Video products Gefen HDMI Switcher 4x1 4x2 6x2 Loewe TV L2700 Loewe TV SL1xx SL2xx SL3xx Setup 5 AV Assignment Assigning audio source Smart audio sources Assigning video sources Setup 5 TV Lift Disable Assignment Setup 5 Reset Assignment Guarantee Included in delivery Technical data Wiring the M200 i...

Page 5: ... dressing the M200 in the side room on Page 10 of this manual You can download the new Mul tiroom Planner V2 00 free of charge from the download area of the Revox Homepage under www revox com New features from software V2 00 From software version 2 00 the M200 can be connected not only to an M51 but also to the M219 Side room amplifier As a result a Loewe television can also be controlled from an ...

Page 6: ...cal 1 3 are always assigned to the IR com mands Local Local 1 Local 2 and Local 3 Continue with point 2 2 Note Monitor only devices This comfort function is only available with TV models with an integrated TV tuner It cannot be selected in case of monitor only devices without a TV tuner 2 2 TV Tuner assignment M200 Setup 5 Input The second assignment affects Setup 5 in the M200 Here the physical a...

Page 7: ...ghlighted in the individual as well as in the follow ing overview table 1 only in combination with an M Link booster see drawings on pages 14 16 2 Relay control through the IR remote control Relay function Remote is only possible if the IR Receiver e g M204 M208 is directly connected to the M200 see drawings on pages 14 16 Function Re system M51 Re connect M219 Relay A B Yes 1 þ Yes 1 2 þ Trigger ...

Page 8: ...ction You will find a detailed descrip tion of the various M200 inter face connection options on the following pages Further Re connect products M201 M202 etc M Link connection activity display Serial interface activity display RS232 seriell interface Re system M51 M10 resp Re connect Installation hole 4 2 mm Slotted hole 4 x 20 mm 15 mm Trigger input A B IN 5 24V Relay A B max 42 Volt Variable vo...

Page 9: ...length 100 m Max cable resistance 0 1 Ω m Connection M200 with external interfaces Socket M51 LINK OUT Setup M219 Yes þ The M200 interface is designed for the connection of further external interfaces M51 operation Currently the following further products can be connected with the M51 4 M200 2 interface 4 M201 IR interface 4 M202 Ethernet interface 4 M203 RS232 interface 4 M217 Display M219 operat...

Page 10: ...ox protocol Even a Windows PC with the M230 control program can be connected to the serial interface on the M200 Serial cables with a maximum length of 10 metres can be used Connection M200 Trigger input Socket INPUT A B RS232 Setup 4 from page 6 M219 No o Using INPUT A and INPUT B you can trigger specific events at the M51 This is done by apply ing a voltage between 5 and 24 volts DC to the corre...

Page 11: ...voltage may not exceed 42 volts Switching voltage 0 42 Volt Max switching current 4 8 A dependent on load See Technical data Connection M200 Voltage ramp Socket Output Setup without configuration M219 No o Using the OUTPUT you can control the output voltage with the remote control M208 giving a variable voltage between 0 and 10 volts This voltage ramp could be used for example to set the dimmer co...

Page 12: ...en ing is used as ground This ca ble may be a maximum of 30 metres in length Please ensure that you use the correct polarity when setting up as otherwise you might damage your equipment Symbols à Pos voltage 12 20V DC IN à IR Signal à Ground Important Relay control through the IR re mote control Relay function Re mote is only possible if the IR Receiver e g M204 M208 is directly connected to the M...

Page 13: ...e Softkeys you can get to pages 1 till 5 Setup page 5 only appears if a video device has been selected on page 4 as Serial Port Mode Setup 1 Control Input Function Trigger input Display Control Input A B Connection Input A B page 4 M219 No o Using INPUT A and INPUT B you can trigger specific events at the M51 The required option can be se lected from an option loop by pressing the Input und Input ...

Page 14: ...le MK 2 or 3 Light Dimmer Activates the voltage output dimmer function Output 0 10V with Toggle Automatic Not Used Deactivates the corresponding input Please note When you are selecting the source you should be aware that the source that has been assigned to the corresponding button in the Remote menu will be selected If a source is dis abled through the Remote menu it will not be activated even w...

Page 15: ...s only available if a Link Booster is installed upstream of the M200 i M219 Cabling The IR Receiver must be con nected directly with the M200 See Connection plan on page 14 Open The relay is in idle state Close The relay is energised Power On Off If the M51 M219 is switched on the relay is energised In standby mode the relay is in idle state TV Lift The relay is energised depend ent on a selected ...

Page 16: ...e control Local 19 Wall mounted remote control Both 30 19 Combination i The remote address has no rela tionship to the slot address which the M200 uses to register with the M51 M219 Setup 3 Source Function IR receiver Display Remote Source Connection inc IR Link page 5 M219 No o Selection of the IR sources that the M200 interface accepts for dimming and relay functions as data suppliers This M 200...

Page 17: ...wing message appears Dis play xx occupied if the selected address is already assigned Setup 4 b Slot M219 M219 operation fig page 13 In respect of the M219 the slot address defines the assignment to the Side room amplifier A M200 can only be connected to an Side room amplifier within the address range x1 x4 The slot address defines which Side room amplifier the M200 interface should communicate wi...

Page 18: ... an M200 Fig B Multiroom version list Zone 3 Setup 4 RS232 Modus Function RS232 interface Display Serial Port Mode Connection RS232 page 3 M219 Yes þ The function of the serial inter face Serial Port can be con figured for the following applica tions RS 232 Link RS 232 Filtered Gefen HDMI Switcher 4x2 4x1 Gefen HDMI Switcher 6x2 Loewe L27xx 1 Loewe SL1xx 2 Loewe SL2xx 2 Loewe SL3xx 2 1 All Loewe t...

Page 19: ... activate a video input e g Tuner or which is disabled Auto Standby OFF After the Loewe TV has been switched on it remains on perma nently until the M51 M219 is switched off irrespective of which audio source is selected RS 232 Link Standardised serial interface RS232 protocol for connection to a PC or another serial inter face Application You should select this setting if you want to use the M230...

Page 20: ... next page If you now select the source SAT Optical at the M51 the Loewe TV automatically transmits the SAT receiver picture over the Input 2 and the sound from the SAT receiver is transmitted over the M51 The convenient integration can of course also be used for the M51 s integrated DVD player Please refer to the picture on the next page Connection Video 1 The audio source and video input links r...

Page 21: ...Configuration M200 Mk2 14 Connection plan Loewe TV L27xx with M51 Connection plan Loewe TV L27xx with M219 Adapter Adapter ...

Page 22: ...Configuration M200 Mk2 15 Connection plan HDMI switch with M51 Note The HDMI output on the M51 is only available if the DVS module is installed Gefen Registered trademark of the Gefen Company US ...

Page 23: ...Configuration M200 Mk2 16 Connection plan Loewe TV with M219 ...

Page 24: ... M200 Setup Product features 4 HDMI inputs 4x1 4x2 6 HDMI inputs 6x2 1 HDMI outputs 4x1 2 HDMI outputs 4x2 whereby both outputs can be operated in parallel Resolution up to 1080p HDCP enabled Optical audio digital output A crossed Sub D cable plug plug is required for the trans mission Type Plug Plug For this reason you should use the enclosed crossover adapter with the supplied Revox cable 9 Pol ...

Page 25: ...t 32 37 42 RS232 interface can be retrofitted Loewe accessories In order to ensure problem free operation the Loewe TVs must meet the following requirements The Loewe televisions with chas sis electronics L2700 or higher require a crossover serial cable also known as a null modem cable as the control cable be tween the M200 and the Loewe television Connection type Plug Plug For this reason you sho...

Page 26: ...cked in the Loewe television Service menu Between the M200 interface and the Loewe TV a special cable is needed Typ RJ12 SubD9 Max cable length 5 m i Audio connection to M219 For the analogue audio connec tion stereo l r between the sideroom amplifier M219 and the Loewe SLxx chassis a D Sub cable harness RCA cube from the Loewe accessories range is needed 1 software packet V3 0 41 or higher is req...

Page 27: ...soft key If too many unknown sources are present we recommend completely resetting the M200 interface by pressing the Dis able softkey for several sec onds until Page 1 automati cally appears 1 Selecting audio source To start with select the M51 M219 audio source that later should activate a particular video input on the Loewe televi sion HDMI Switcher using the Source softkey Using the Source and...

Page 28: ...e respectively TV ON and TV OFF function keys in the remote con trol menu The semi intelligent sources such as the M37 Music Server store the last selected state If for example the video input from the Server was activated at the television using the remote control the television is auto matically activated next time this source is selected 3 Intelligent sources In the case of intelligent sources ...

Page 29: ...oftkey Store appears as confirmation each time the Input is changed Press Store if you want to save your changes Otherwise the original setting is retained The following display appears if a video input is called by one or more audio sources Assignment example This example shows you that as well as the currently displayed audio source DVD a further audio source has also been assigned to this video...

Page 30: ...20 sec onds This prevents the screen from being retracted and rolled out again unnecessarily for ex ample in the case of an acciden tal source change Please refer to page 8 Setup 2 for the configuration of the relay function Example Settings definition Setup 5 Settings definition Setup 2 Effects 1 à Setup 5 The audio source DVD CD switches the Loewe television on over to the video input HDMI 2 as ...

Page 31: ...rce softkeys and then press the Disable softkey The Store soft key then appears that you need to press to confirm your change If you don t press Store the original setting is retained Reset assignment If you want to return the settings in Setup 2 menu to the factory settings simply press and hold the Disable softkey until the Setup 1 page appears again This resets all input assignments and restore...

Page 32: ...ou the help you need send your M200 interface carriage free and without any accessories to your national Sales Office Please supply a complete de scription of the problem and a full return postal address Included in delivery M200 Domotic Interface M51 Link cable 2 m Serial PC cable 1 1 length 3 m Plug Plug Crossover adapter Gender adapter Accessories Installation Manual ...

Page 33: ...lt DC Threshold voltage 5 Volt DC input resistance 2 kOhm Please ensure correct polarity OUTPUT Output voltage 0 10 Volt DC Max output current 10 mA Please ensure correct polarity IR LINK à Positive voltage 10 20V DC IN à IR signal à Ground GND Dimensions 140 x 65 x 40 mm W x H x D Weight 330 g Power consumption 36 mA without IR receiver Max cable length 100m M200 M51 Max cable length 30m M200 IR ...

Page 34: ...Appendix M200 Mk2 27 Wiring the M200 interface ...

Page 35: ...if the system address 02 is selected for the Loewe television instead of the 00 The system address is changed in the following way At the Loewe television board operating element Œ Press the M button briefly Press the button briefly Then at the Loewe Assist 1 remote control Ž press the MENU button within 1 second Now the service menu should be visible Select the sub menu Other adjustments from thi...

Page 36: ...nd switching with SCART connection between M51 and Loewe television Sound switching for dual channel transmissions is only possible at the Loewe television s audio output Cinch socket not at the SCART output This means that if the Loewe television is connected with the M51 using a SCART cable Eurosport for example can be heard in parallel in German through the lefthand channel and in English throu...

Page 37: ...21 8704 29 info revox de www revox de SCHWEIZ Revox Schweiz AG Wehntalerstrasse 190 CH 8105 Regensdorf Phone 41 44 871 66 11 Fax 41 44 871 66 19 info revox ch www revox ch Zentralservice Revox GmbH Am Krebsgraben 15 D 78048 VS Villingen Phone 49 7721 8704 43 Fax 49 7721 8704 49 info revox de M200 MK2 Interface Loewe manual Part no 10 30 3098 ...