MAN-000020-00 REV A
36
6. Battery Over-Temperature
The following screen will appear the first 5 times the battery over-temperature limit is
exceeded during any charge cycle. On the first instance of detecting a battery over-
temperature, the Charger will wait until the battery temperature drops approximately
7°C (13°F) and then re-start the charge cycle automatically. If another over-
temperature fault is the encountered, the charger waits for an 8°C (14°F) drop before
re-starting the charge cycle. The Charger increments the delay until an 11°C (20°F)
drop is required before restart.
If the battery temperature limit is exceeded once again, the Charger will stop the
charge cycle and display the following screen:
Possible Causes
Charge and/ or discharge rates too high.
CV and Finish modes running too often.
Room temperature excessive.
Troubleshooting
a. Select
STOP
to revert to the
Connect Battery
or
Push START
screens.
b. Allow the battery to cool down.
c. Restart the charge cycle by selecting
START
.
d. If the fault persists, contact the Dealer or Power Designers USA LLC.