background image

Contents of box:   

Fusion Base Station and four or eight wireless microphones (any type) 

 
 
 

 

 

 
 

 
 

 
 
 

 

Optional boxes:   

Four or eight wireless microphones, Remote IR Sensor, speakers 

Cable A 

Speakers 

Cable B 

Phone Cable 

Cable C 

RCA 

Cable D 

XLR 

Set-Up Guide 

Page 4 

AC power adapter for Base Station 

Charger Base and  

AC wall adapter for Charger Base 

Remote Control 

Fusion Base Station vertical stand 

Summary of Contents for Fusion

Page 1: ...Rev 1 12 Revolabs Fusion Wireless Microphone System Set Up Guide ...

Page 2: ...ferencing 8 Video conferencing Configuration 8 Pairing Microphones to Fusion Base Station 9 Polycom Installation 12 Tandberg Installation 14 Lifesize Installation 15 Sony Installation 16 Programming Port DIP Switches 18 Multiple Fusion Systems 19 Tabletop Master Mute 20 Auto Phone Answer 21 Remote IR Sensor 22 Hearing Assistance 23 Indicator Lights 24 Safety and Regulatory Information 26 Specifica...

Page 3: ...rophone Solution into an analog telephone jack and you are on your way to great wireless teleconference calls There is a remote control dialer to dial the conference phone number You may connect to powered speakers connect to existing speaker system or connect to a new room speaker system to hear the call Decide on where you want to put the Fusion system whether you want it vertical or horizontal ...

Page 4: ...tional boxes Four or eight wireless microphones Remote IR Sensor speakers Cable A Speakers Cable B Phone Cable Cable C RCA Cable D XLR Set Up Guide Page 4 AC power adapter for Base Station Charger Base and AC wall adapter for Charger Base Remote Control Fusion Base Station vertical stand ...

Page 5: ...udio signal processing and pairing between the Solo microphones and the Fusion Base Station 1 IR Remote receiver if not in sight range of remote page 22 2 LED indicators Displays microphone mute and pairing states 3 Pairing Push Buttons For pairing microphones to Base Station page 9 4 Power On LED Volume indicator Page 5 Revolabs Fusion ...

Page 6: ...IN CONFERENCE OUT 3 Conference Out XLR Microphone level 4 Network RJ 45 Revolabs use only 5 Telephone Line in RJ11 6 Telephone Set in RJ11 7 Audio Control RJ45 Revolabs use only 8 Programming Port LEFT DIP Switches 1 8 refer to page 18 9 Programming Port RIGHT DIP Switches 1 8 Revolabs Use Only 10 DB9 Revolabs use only 11 IR Remote DB9 Set Up Guide ...

Page 7: ...ed to use the Remote IR Sensor part number 07 IRREMO 01 for remote to work Refer to page 22 Power Plug AC power adapter power cord into the back of the Fusion Base Station and into wall outlet Plug AC wall adapter into the power outlet and the other end into the microphone Charger Base Place wireless microphones in the Charger Base let charge overnight or at least eight hours Indicator lights on t...

Page 8: ...mbers you must first establish a connection between your microphones to the Fusion Base Station This is called pairing Refer to page 9 STEP 2 Video Conferencing You must have the audio output going from the Fusion Base station directly to the speakers used by the video conferencing station Plug Cable A single RCA to double RCA single RCA connector into Fusion Base Station Room Out RCA port and the...

Page 9: ...es are always muted flashing RED LED light when they are removed from the Charger Base and the MUTE button needs to be pressed to make it live flashing GREEN LED A microphone that is not paired will be indicated by either cycling RED GREEN or RED YELLOW GREEN LED patterns A Base Station LED that is not paired to a microphone will not show any activity on the LED make sure unit is first powered on ...

Page 10: ...ing mode then release The LED for that channel will be solid red until pairing starts as indicated by a quick GREEN flash then switching to flashing RED on both the microphone and the Base Station muted audio Pairing is now complete The Fusion Base Station has four or eight indicator LED lights one for each microphone and pairing push buttons on the front panel When the LED is flashing GREEN or RE...

Page 11: ...st popular video conferencing systems If you cannot find your specific video conferencing station and need assistance in configuring the cables check the additional documentation in the FAQs or Technical Documentation sections on www revolabs com or the video conferencing station documentation Page 11 Revolabs Fusion ...

Page 12: ...Conf In 2 Plug the black RCA connector on one end of Cable C into Polycom video station Audio In and then plug the black RCA connector on the other end into the Fusion Base Station Conf Out To configure the Polycom system Select the button from the main screen to access the System menu Select the System Admin settings Enter the administrator password and press OK if needed Select the Audio setting...

Page 13: ...ther end into the Fusion Base Station Conf Out 2 Plug the 3 5mm 3 pin cable into the Polycom video station Audio Out 1 Red and then plug the RCA connector on the other end into the Fusion Base Station Conf In To configure the Polycom HDX 9000 Series system Select the button from the main screen to access the System menu Select the System Admin settings Enter the administrator password and press OK...

Page 14: ...her RCA connector is not used 2 Plug one XLR connector of Cable D XLR to XLR into Tandberg video station Mic 1 Input and the other XLR connector into the Fusion Base Station Mic Level Output Conf Out Mics To configure the Tandberg system Select the button from the main screen to access the System menu Go to Audio settings Confirm or modify the following settings Input 1 MIC Output 1 ON Audio Level...

Page 15: ...ne end of Cable C into Tandberg video station Audio Out 1 and then plug the black RCA connector on the other end into the Fusion Base Station Conf In The other RCA connector is not used To configure the Tandberg system Select the button from the main screen to access the System menu Go to Audio settings Confirm or modify the following settings Input 1 MIC Output 1 ON Audio Leveling OFF Echo Cancel...

Page 16: ...nf In 2 Plug the black RCA connector on one end of Cable C into Lifesize video station Audio In and then plug the black RCA connector on the other end into the Fusion Base Station Conf Out To configure the Lifesize system Select the button from the main screen to access the System menu Select the Administrator Preferences settings Enter the administrator password and press OK if needed Select the ...

Page 17: ...ny video station Audio Out 1 and then plug the red RCA connector on the other end into the Fusion Base Station Conf In 2 Plug one XLR connector of Cable D XLR to XLR into XLR Female to 3 5mm adapter cable and then to the Sony video station Mic 1 Input and the other XLR connector into the Fusion Base Station Mic Level Output Conf Out Mics To configure the Sony system Select the Audio settings drop ...

Page 18: ...ogramming Port 9 page 6 on the right is reserved for Revolabs Use Only NOTE The Fusion system must be powered off and back on for any DIP Switch changes to take effect OFF ON Transmit Power Medium Frequency A Mode Tabletop Master Mute Frequency B Mode Phone Auto Answer Transmit Power Low 1 2 3 4 5 6 Page 18 IR Remote Set Up Guide Hearing Assistance 7 8 ...

Page 19: ...es and Fusion Base Station can be set to the following three levels Highest power level default 100 feet 30 5 m maximum operating distance between Microphone and Fusion Base Station DIP Switches 1 and 2 are OFF page 18 Medium power level 30 feet 9 m maximum operating distance between Microphone and Fusion Base Station DIP Switch 1 is ON and DIP Switch 2 is OFF page 18 Lowest power level 8 feet 2 4...

Page 20: ...turn to their prior state DIP switch 5 is OFF page 18 Tabletop Microphone Master Mute In addition to the Remote Control MUTE button muting all of the microphones the Solo Tabletop microphone MUTE button will also act as a master mute and mute all active microphones Pressing any Tabletop microphone MUTE button or the Remote Control MUTE button will unmute all tabletop microphones All wearable and h...

Page 21: ... Call key DIP switch 6 is OFF page 18 Auto Answer To answer a phone call and begin a teleconference the user may use the Remote Control and press the Call key or the Fusion Base Station will automatically answer the call after two rings DIP switch 6 is ON page 18 NOTE The Fusion system must be powered off and back on for any DIP Switch changes to take effect Page 21 Revolabs Fusion ...

Page 22: ...and behind a door non metal the front panel IR Sensor cannot work The Remote IR Sensor cable part number 07 IRREMO 01 must be used to position the Fusion IR Sensor outside of the cabinet Plug the serial plug end into the IR Remote connector on the back panel of the Fusion Base Station page 9 bring IR Sensor end out of cabinet and secure with Velcro then set DIP switch 7 to ON page 18 NOTE The Fusi...

Page 23: ...d Within The Room If the user needs to hear the audio from both the far end and the other microphones within the room he she must use the microphone paired to Channel 8 refer to pairing mode page 9 and the DIP switch 8 must be set to ON page 18 Please note that the Room Out RCA plug will no longer function in this mode Aux Out will serve as Room Out NOTE The Fusion system must be powered off and b...

Page 24: ...very 1 5 seconds GREEN flash every 1 5 seconds Solid RED Alternating slow GREEN and RED YELLOW flash alternating with GREEN YELLOW flash alternating with two RED flashes Alternating RED YELLOW GREEN YELLOW Rapid RED flashes continuing for more than a few seconds Groups of five rapid RED flashes One RED flash every 1 5 seconds Page 24 Set Up Guide ...

Page 25: ...shing Microphone low battery mic live RED Flashing Microphone low battery mic muted OFF Searching for a connection or out of radio range The Microphone will try to re establish the link for about 15 minutes and then turn off OFF Radio congestion it is not possible to make a radio connection because there are already too many nearby users or there is heavy radio interference OFF Unit is faulty Cont...

Page 26: ... maintained between the Fusion Base Station and users and or nearby persons bodies at all times Additionally the Fusion Base Station must not be co located with any other antenna or transmitter This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference receiv...

Page 27: ...o communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increa...

Page 28: ...hysician may be able to assist you in obtaining this information EXPORT LAW ASSURANCES This product is controlled under the export regulations of the United States of America and Canada The Governments of the United States of America and Canada may restrict the exportation or re exportation of this product to certain destinations For further information contact the U S Department of Commerce or th...

Page 29: ...phone 03 EXECHGEU STD 11 Revolabs Solo Executive Charger 05 TBLMICEU OM BLK 11 Revolabs Solo Executive Table Microphone Omni 05 TBLMICEU DR BLK 11 Revolabs Solo Executive Table Microphone Cardioid 06 XLRMICEU OM BLK 11 Revolabs Solo Executive XLR Microphone Adapter STANDARDS TO WHICH CONFORMITY IS DECLARED RF ETSI EN 301 406 V 1 4 1 03 2001 EMC ETSI EN 301 489 6 v1 2 1 2002 04 WEEE NOTIFICATION Th...

Page 30: ... DB9 for Revolabs use only Audio Control RJ45 for Revolabs use only Telephone Line In RJ11 Telephone Set In RJ11 Network RJ45 for Revolabs use only Conference Out XLR male Aux In RCA Plug Aux Out RCA Plug Record Out RCA Plug Room Out RCA Plug Conference In RCA Plug Conference Out RCA Plug Charger Base DC power input port Proprietary 4 pin microphone charge jacks Power Requirements Fusion Base Stat...

Page 31: ...ment damaged by negligence accident or Acts of God voids this warranty The Seller shall not be liable for any consequential damage resulting from the malfunction of this product Should the user experience unsatisfactory performance from this equipment contact the Seller to obtain instructions for return or replacement as deemed necessary This warranty is not transferable by the original end user R...

Page 32: ...y be reproduced in any form or by any means without express written permission from Revolabs Inc Product specifications are subject to change without notice Microphones must be fully charged and paired to the Fusion Base Station prior to first use Part 295034 REV 1 12 ...