To pair an individual microphone to the Base Station:

 

1.  Turn the microphone OFF (no LED activity). If the microphone is ON, press and hold the Mute 

button for 10 seconds until the LED turns solid RED then release the button to turn the unit off. (do 
not release the button when you hear two beeps).  

2.  Place the microphone unit into pairing mode by holding the Mute button down for seven seconds. 

The LED will turn solid RED. Release the Mute button. The microphone is now in pairing mode. 

3.  Within one minute, push and hold the button for the desired channel on the Base Station for seven 

seconds until the LED turns solid red then release. The LED for that channel will be solid red until 
pairing starts, as indicated by a quick GREEN flash, then switching to flashing RED on both the 
microphone and the Base Station (muted audio). Pairing is now complete.

 

 

 

 

 

 

 

 

 

 

 

 

Revolabs Executive HD Charger Base 

When Microphones are not in use, they should be properly inserted into the Executive HD Charger 
base.  It  is  important  to  ensure  that  all  system  microphones  are  inserted  fully  in  the  base  so  that 
charging will occur. While charging in the Charger Base, the Charger Base USB connection may be 
used  to  either  update  HD  Microphone  firmware  or  “Express  Pair”  the  microphones  to  the  Base 
Station.  The  microphone  charging  ports  are  numbered  1-8  from  left  to  right  and  back  to  front. 
Therefore the rear left port is number 1 and the front right port is number 8. Features of the base are 
shown in the following figure. 

 

 
 
 
 

 
 
  1. 

LED indicator

 — power status indicator.   

  2. 

Charger Bays

 — charges up to 8 Microphones.  

  3. 

Mini USB Interface

  — computer serial interface for firmware upgrades to the microphones (on rear). 

  4. 

Power Cord Receptacle

 — power supply input, 9-24VDC (on rear). 

Summary of Contents for 01-HDEXEC-NM

Page 1: ...dels 01 HDEXEC NM 01 HDEXEC4 NM 01 HDEXEV NM AES 01 HDEXEC4 NM AES 03 HDEXECEU NM 03 HDEXEC4EU NM 03 HDEXECEU NM AES 03 DEXEC4EU NM AES 03 HDEXECCN 03 HDEXEC4CN 03 HDEXECJP 03 HDEXEC4JP 03 HDEXECJP AE...

Page 2: ...t of this document may be reproduced in any form or by any means without express written permission from Revolabs Inc Product specifications are subject to change without notice Revolabs Executive HD...

Page 3: ...Together 9 Using the Rear Panel Configuration DIP Switches 11 Using the Revolabs HD Control Panel Software 11 Using the Serial Control Processor RS 232 or IP 18 Using the Base Station Front Panel Disp...

Page 4: ...onal Installation Recommended This product should be professionally installed Industry Canada Notice to Users Operation is subject to the following two conditions 1 This device may not cause interfere...

Page 5: ...d Telecommunications Terminal Equipment Conformity of the Equipment with the guidelines below is attested by the CE mark Model Numbers 03 HDEXEC4EU NM Executive HD System 4 Channel w o mics 03 HDEXECE...

Page 6: ...ision Multiple Access and Time Division Duplex MC TDMA TDD radio transmissions both to and from the microphone This technology allows the microphones to co exist with other wireless products operating...

Page 7: ...plex audio The Charger Base stores and charges the wireless microphones when not in use The Charger Base also serves as a programming station for the microphones should firmware updates to the microph...

Page 8: ...n BUS synchronization connection 11 RS 232 Serial Interface DB9 see Section Using the Serial Control Processor RS232 or IP 12 Base station status LED s see Section Revolabs Executive HD Indicator LEDs...

Page 9: ...ble microphone Depending on the application it is possible to feed a single mixed channel back to all earpieces or alternatively each user can receive a separate and unique channel This would allow fo...

Page 10: ...cycled for the switch setting to be registered Warning The switch must be in the Primary position for a single Base Station system which is the factory default setting Microphones will not function i...

Page 11: ...to the PC using the provided USB USB Mini cable 4 Install the software downloaded in Step 1 which requires Windows 2000 NT Vista or 7 5 If no DHCP server is present set the fixed IP on the PC to a sim...

Page 12: ...tings can also be controlled from the Base Station front panel display All configuration settings are located either in the Config tab of the device window or on the HD Control Panel menus File Record...

Page 13: ...ssword is assigned it must be entered to communicate with the Base Station over Ethernet via the HD Control Panel Software The Telnet Password can be set by selecting Set Password from the System menu...

Page 14: ...l program See Updating the Revolabs HD Firmware for more information Tools Express Pair The Express Pair tool allows all of the HD microphones in an Executive HD System to be paired simultaneously via...

Page 15: ...Base Station can be adjusted to help reduce the operational radius of an Executive HD System in order to prevent interference from other Revolabs products or from other devices operating in the same f...

Page 16: ...system Note Selecting the Pairing Lock function will automatically reboot the HD base station Config Audio Zone Each Executive HD base station that is bussed together using the 3 conductor BUS cable...

Page 17: ...The microphone gains are stored in the Base Station and will be applied to any microphone paired to that channel Monitor Microphone Status This provides the current status for the microphone paired t...

Page 18: ...t Pin 2 Rx Pin 3 Tx Pin 5 GND Pin 7 RTS Pin 8 CTS Using the Executive HD Base Station with a Control System The Executive HD Base Station is capable of being monitored and controlled via any serial ca...

Page 19: ...ith val and terminate with a Carriage Return You will receive a Return String for every value change that has taken place in the microphones or base station including changes that are a result of the...

Page 20: ...atus get fp Base Front Panel Lock Status get tm Base TableTop Mute Status get um Base UnMute Startup Status get fw System Firmware Revisions val lock 1 8 ch 1 8 0 Mic Lock Off 1 Mic Lock On val mute 1...

Page 21: ...ery status of mic 5 100 Command get batt ch 5 Return val batt ch 5 4 Using the Executive HD Base Station with a DSP The Executive HD system is designed to control the mutes of a DSP directly in the ev...

Page 22: ...Station to match the communication settings of the Biamp DSP as well as select the Audio Channels of the microphones that the Base Station is to simulate i e 1 8 9 16 etc Each Base station will contro...

Page 23: ...g DSP product line from the Serial Control Processor menu in the Revolabs HD Control Panel software You must also set the RS 232 or Network settings of the Base Station to match the communication sett...

Page 24: ...channel is inactive the microphone is out of range or turned off The LCD and menu buttons are designed to provide the system installer the ability to access certain configuration settings directly fro...

Page 25: ...apter for Countryman Microphones Using the HD Wearable Wireless Microphones The Revolabs HD Wearable Microphones shown in the following figure are paired to the Base Station and can be worn on the use...

Page 26: ...d the Mute button for 10 seconds until the LED turns solid RED then release button If the microphones are moved out of range of the Base Station 300 feet or 91 meters the connection will be dropped LE...

Page 27: ...op microphones can be centered on the table within 2 to 6 feet 0 6 to 2m away from people speaking and do not need to be pointing any particular direction because they pick up sound from all direction...

Page 28: ...ack accepts a 2 5mm plug 4 Charging port docks to Revolabs HD Charger Bases 5 Mute button press to mute un mute and pair microphone 6 Acoustic Cover protects microphone element non removable To use th...

Page 29: ...If not the microphone will continue beeping until it turns off in about 15 minutes Using the HD XLR Microphone Wireless Adapter The HD Wireless XLR Adapter for Handheld Microphone shown in the follow...

Page 30: ...e Base Station 300 feet or 91 meters the connection will be dropped LED flashes all colors and the audio will mute After 15 seconds the microphone will beep 5 times and will continue beeping every 30...

Page 31: ...iginal state and the beeping will cease If not the Countryman Adapter will continue beeping until it turns off in about 15 minutes Pairing Wireless Microphones to Base Station Pairing creates a link b...

Page 32: ...ing RED on both the microphone and the Base Station muted audio Pairing is now complete Revolabs Executive HD Charger Base When Microphones are not in use they should be properly inserted into the Exe...

Page 33: ...ry to modify any of the batteries delivered with the Revolabs HD microphones The latest releases of the Revolabs HD microphones include field replaceable batteries Replace these batteries only with Re...

Page 34: ...an be used for all Revolabs HDTM Products Communication to the Base Station is done over an Ethernet connection and communication to the microphones is done through the Charger Base via Mini USB cable...

Page 35: ...ct OK and watch the firmware process either on the Base Station front panel display or in the monitor tab in the Revolabs HD Control Panel program The HD Control Panel will notify you when the process...

Page 36: ...ow GREEN and RED Alternating slow GREEN and RED Microphone or channel not paired YELLOW flash alternating with GREEN GREEN Flashing Microphone low battery mic live YELLOW flash alternating with two RE...

Page 37: ...same way as with regular Executive HD systems It is transparent to the user that AES 256 encryption technology is being used Revolabs Executive HD MaxSecure receivers and HD MaxSecure microphones can...

Page 38: ...gence accident or Acts of God voids this warranty The Seller shall not be liable for any consequential damage resulting from the malfunction of this product Should the user experience unsatisfactory p...

Page 39: ...o 1 92 GHz DECT CN and other CN products 03 HDEXECJP 1 895 to 1 903 GHz DECT JP and other JP products Maximum Output 15 7dBm 37 15mW Channel spacing 1 728 MHz Modulation GFSK Class ISM Connectors Base...

Page 40: ...DEXEC4CN AES 24 channels recommended 6 systems 03 HDEXECJP AES 16 channels recommended 2 systems 03 HDEXEC4JP AES 16 channels recommended 4 systems In Maximum Density mode 12 000 Hz audio 01 HDEXEC AE...

Page 41: ...nectors 9 LED indicator 32 MC TDMA TDD 6 Microphone Charging port 25 Earpiece Jack 25 LED Display 25 Mute Button 25 Pocket Clip 25 Microphones 25 Pairing 24 31 Power Cord Receptacle 32 Power In Recept...

Page 42: ...42 Revolabs Executive HD Manual 01 EXEMAN PAP 11 April 2013 Rev 2 6 Note Microphones must be fully charged and paired to the Base Station prior to first use...