12
2.6 Setting Dome Camera Protocol and Video
If a dome camera is to be installed with the keyboard controller, select the default protocol.
Consult service personnel if a dome camera is installed with device other than a keyboard
controller.
S2
You can set video type with dip switch.
Select video type with D1 in S2
You can set Protocol with dip switch D2, D3 and D4 in S2.
S2
D2
D3
D4
P
ROTOCOL
OFF
OFF
OFF
F2, RT, Pelco-P, Pelco-D :
default
OFF OFF
ON
F2, RT
OFF
ON ON
Pelco-P, Pelco-D
You can set Baud Rate with dip switch D5 and D6 in S2.
S2
D5
D6
B
AUD
R
ATE
OFF OFF
2400
bps
OFF
ON
4800 bps
ON
OFF
9600 bps :
default
ON ON
19200 bps
Figure 5 – Video type, Protocol, Baud rate Selection Switches
S2-D1
V
IDEO TYPE
OFF NTSC
ON
PAL