HRV / ERV INSTALLATION AND 

OPERATION INSTRUCTIONS

Field Balancing Ports

RHRV-C100PECM

Polypropylene Core

RERV-C100ECM

Enthalpy Core

Summary of Contents for RERV-C100ECM

Page 1: ...Canada L4L 5V3 Tel 905 851 6701 Fax 905 851 8376 www reversomatic com info reversomatic com US CERTIFIED C New HRV ERV INSTALLATION AND OPERATION INSTRUCTIONS Field Balancing Ports RHRV C100PECM Polypropylene Core RERV C100ECM Enthalpy Core ...

Page 2: ...llation servicing or cleaning these unit it is suggested to wear safety glasses and gloves 9 Do not use this unit for commercial purpose 10 For residential use only The unit must be grounded 11 Do not install in a cooking area 12 This unit is not designed to exhaust combustion and or dilution air for fuel burning appliances CAUTION 1 Turn the unit OFF during construction or repair to avoid filter b...

Page 3: ...rol Board Superior ECM 9361 ECM 1 1 14 Main Control Board Bracket 9355 2 2 15 Door Hinges 9328 1 Set 1 Set 16 Mounting Brackets 011135 4 4 17 T Connector 9330 1 1 18 Webbing Brackets Ladder Locks 9332 2 Sets 2 Sets 19 Chains Springs Brackets 9354 1 Set 1 Set 20 Drain Pipe 9331 1 1 21 Motorized damper spring return 120V 9362 1 1 22 Motorized Damper Spring return Built in by Factory 9363 1 1 Parts L...

Page 4: ...5 DAT GND YEL RED GRN YEL RED GRN TC100 5V YEL RED GRN Intermittent OR Timer Switch 1 FAN Exhaust FAN Supply AC connection Door Safety switch Temp Sensor Exhaust FAN motor f HRV ERV Hi Low 120 Vac 1 60Hz Power Supply Light Switch Option b Light On Off Remote 0n 0ff HV Jumper remove jumper to install master ON OFF switch Ext Interlock OR Ground DC connection Note Make sure the Line must be connected ...

Page 5: ...HERMOSTAT TERMINALS W R G Y TWOWIRE W A R N I NG Never connect a 120 volt AC circuit to the terminals of the furnace fan coil heat pump interlock Standard Wiring Only use the low voltage class 2 circuit Note These Connections must be done inside the electricalbox NO C NC These connections must be done inside the electrical box FOUR WIRE GND DAT 5V SUPERIOR ECM CONTROLBOARD W R G Y C TWOWIRE heatin...

Page 6: ...r in Recirculation Installation Options for High Rise Condominium Fully Ducted System System FRESH AIR EXHAUSTEDAIR Typical Installations for House Fully Ducted System This is a stand alone HRV ERV system which is not connected to a force air system Stale air is drawn from key areas of the home bathroom kitchen while fresh air is supplied to main living areas Furnace Return Air duct Connection DVS...

Page 7: ...e person installation for vertical and horizontal installation VERTICAL Note After installation make sure the HRV ERV is properly leveled If not levelled correctly then defrost will not perform effectively and or unit may frost in winter UP UP PULL DOWN Strap NOTSUPPLIED j tantay 12 23 11 Vibration Spring Washer Screw CHAIN MOUNTING SYSTEM optional Available for both horizontal vertical installati...

Page 8: ...e this drain for horizontal installation Note For Horizontal installation connect only 1 drain spout assembly on lid door cut one drain pipe and connect one end to the drain spout and the other end to the drain line Don t forget to create a P trap as shown above HRV must be connected to drain ERV does not required any drain However we recommend to connect ERV to drain in areas where extreme cold w...

Page 9: ...from the other duct The flows should now be balanced Actual airflow can be determined from the gauge metre reading The value read on the gauge is called the velocity pressure and on the flow meter is called air velocity FPM The Pitot tube comes with a chart that will give the air flow velocity based on the velocity pressure indicated by the gauge This velocity will be in either feet per minute or metr...

Page 10: ...slide it to the left 3 Clean the inside of the door and drain pan with a damp cloth to remove dirt and debris that may be present 4 Clean the filters twice a year Remove the filters Vacuum to remove most of the dust Wash with a mixture of warm water and mild soap Rinse thoroughly and shakefilters to remove water and let dry 5 Oil grease defrost damper levers and hinges 6 Check air flow sensors twice a...

Page 11: ...he fan motor wires remove the screws securing fan assembly pull the fan assembly out of unit check for any accumulation on the blades clean with a small brush if necessary scrub individual fan blades until clean vacuum and wipe put the components back in place reconnect the power supply and turn the unit back on PROBLEMS POSSIBLE CAUSES SOLUTION 1 Air flow is low HRV ERV airflow improperly balanced ...

Page 12: ...and the remote wall mount Timer Switch will flash 0 5 sec On 0 5 sec Off 0 5 sec On then 2 sec Off then repeat the cycle Exhaust fan open circuit a motor burned b fan overheated replace motor call technician if possible replace fan damper obstructed exhaust fan jam over current check backdraft damper no screw must interfere the function of the damper replace the fan 8 LED s on the Main Control boa...