PREPARATION FOR INSTALLATION: 

■ 

Feed water cannot be hot. It damages the RO membrane. 

■ 

The perfect range of feed water pressure is between 5-25 psi. 

If the feed water pressure is higher than 3.0Kg/cm

2

/40 psi, install the reduced pressure valve or take 

off the booster pump. Otherwise the high water pressure may reduce in the leakage or break down. 

If the feed water pressure is lower than 0-0.3Kg/ cm

2

/0-5psi, you have to wider the tube or shorten 

the length of the pipe to the help the pump run normally. Otherwise, it may result in the reduction of 

the production rate & percent rejection, the pump to deliver water. 

■ 

Avoiding to install the purifier at the place where is damp, low temperature (<4

) of the system or 

high temperature (>40

■ 

The storage tank can be place on its side without affecting the performance of the system. If there is 

insufficient room under the sink, the tank may be located in an adjacent cupboard. 

 

INSTALLATION OF WATER SUUPLY CONNECTION: 

A. Water Supply Connector 1/2” FIP (L:36m/m) 

(FWC-0808)

 

B. Deliver-

Ball Valve 1/4”MIP x1/4”OD1/4” 

(BV-0404)

 

 

Assemble the water supply connector by inserting the Deliver-ball valve. Screw the deliver-ball valve 

into the side of the water supply connector using 3 to 4 wraps of Teflon tape. 

Disconnect  the  water  supply  line  from  the  feed 

water  faucet  underneath  sink.  Attach  and  tighten 

water supply connector assembly being careful not 

to  pinch  or  crimp  any  tubing  or  water  supply  line 

while tightening.

 

 

FAUCET INSTALLATION 

 

Using the 1/4

” drill bit, drill a 1/4” hole through the base metal. Operate 

the  drill  slowly  and  carefully,  especially  when  the  drill  is  about  to 

penetrate the metal. If necessary use two drops of oil in the hole. 

Repeat step 1. Using the 1/2

” drill bit. Mount the faucet in the hole and 

using  an  adjustable  wrench  (or  hand)  to  hold  the  faucet,  tighten  the 

9/16

” nut. 

*** If it is not available to drill a hole, you may use a faucet-bracket instead. ***

 

 

Summary of Contents for BlueClear-RO-50

Page 1: ...smosis Water Cleaner Installation and User Manual BlueClear RO 50 BlueClear RO 50 P BlueClear RO 75 BlueClear RO 75 P BlueClear RO 100 BlueClear RO 100 P Please read these instructions completely before operating the unit ...

Page 2: ...fficient room under the sink the tank may be located in an adjacent cupboard INSTALLATION OF WATER SUUPLY CONNECTION A Water Supply Connector 1 2 FIP L 36m m FWC 0808 B Deliver Ball Valve 1 4 MIP x1 4 OD1 4 BV 0404 Assemble the water supply connector by inserting the Deliver ball valve Screw the deliver ball valve into the side of the water supply connector using 3 to 4 wraps of Teflon tape Discon...

Page 3: ...water purified Usually 2 to 3 hours After the tank has full you will hear no water running to the tank open the sink top faucet and drain all the water until the storage tank is empty and there is only a small flow from the sink top faucet Do not drink the water from the first tank produced by your newly purchased system or newly replaced membrane If the system is only used infrequently drain the ...

Page 4: ... 1 or 2 times Leaks from unit or filter housings Leaks can be caused by loose fittings a missing damaged or improperly seated o ring or an improperly inserted plastic ferrule on the brass fitting If the fittings are not tightened then carefully re tighten the fittings If the o ring is missing or damaged then contact a dealer for a replacement If the o ring is out of round make sure the o ring is p...

Page 5: ...ide of all housings with a mid soap solution and then rinse with R O water Lube o ring with a water soluble lubricant and replace in groove in filter housing Insert new filters into appropriate housings Follow the normal start up procedures 2 MEMBRANE CHANGE PROCEDURE Disconnect the tube from membrane housing Unscrew the large end of the membrane housing Slide out the used membrane and discard Cle...

Page 6: ...diment Filter from 100 Melt Blown Polypropylene Sediment Sand Silt Dirt Dust particles removal Operation Pressure Temp 120psi 60 140F Use only for Water without microbiologically and adequately Please remove plastic wrap before use Flush 5 minutes at least prior to use Suggested usage life 6 months Carbon block 1UM nominal filtration rating Performance tested verified by independent laboratory tes...

Page 7: ...lement this into your water filtering system you will get water of very high quality This ultra pure water is very good for your health and seeing that 70 of your body mass is water you know that your water intake will benefit your health FIR cause resonance with water molecules It ionizes and activates water molecules in our cells and blood thus improving our blood circulation and health conditio...

Page 8: ...alcium Ca2 Magnesium Mg Sodium Na Potassium K2 Operation Pressure Temp 125psi 60 Maximum Flow 0 75 GPM Note the flow direction marked on filter prior to installation Suggested usage life 1 year P S More people use or bad water quality have to shorten time to change filter Water pressure and water quality exceed limit please call distributor to set up and increase the life time of machine ...