1. 

INTRODUCTION

Thank you very much for purchasing air water heater FARMER HCF. We would 
like to congratulate you on excellent choice. Please read and keep this manual. 

1.1  

PRECAUTIONS

The buyer and the user of the air water heater Reventon Group brand should 
read  carefully  the  following  instructions  and  proceed  to  the  content 
recommendations.    Proceeding  due  to  the  following  instruction  guarantees 
the  correct  usage  and  safety.  In  case  of  any  doubts  please  contact  directly 
the producer Reventon Group sp. z o. o. [Ltd.]. The producer reserves the rights 
to  make  changes  to  the  technical  documentation  without  previous  notice. 
Reventon Group sp. z o. o. [Ltd.] is not responsible for the damages which occur 
due to improper installation, not keeping the device in repair or using the device 
out of line. The installation should be carried out by the professional installers, 
who possess the qualifications to install these types of devices. The installers 
are responsible for making the installation as instructed in the technical data. 
In  case  of  unserviceable  please  plug  out  the  device  and  contact 
with  the  authorized  for  repair  person  or  the  supplier.  During  the  installation, 
use,  service  and  periodical  inspections  all  regulations  and  safety  rules 
must be followed.

1.2  TRANSPORT

During  the  acceptance  of  goods,  it  is  needed  to  check  the  device  to  exclude 
any damages. During the transport, it is needed to use the proper equipment, 
it is necessary to carry the device by two people. In case of any damages please fill 
in the damage report in presence of the supplier.

1.3  

PACKAGE CONTENT

- h

eater

- o

peration and maintenance manual and warranty card

1.4 USE 

Reventon Group Farmer HCF heating devices are designed for heating or cooling 
surfaces  in  which  aggressive  conditions  prevail,  i.e.  high  content  of  acids, 
ammonia and high concentration of dust. However, heaters should not be used in 
highly  corrosive  environments  for  aluminum,  copper  and  steel.  The  devices 
should also not be installed in rooms where they would be exposed to the high 
humidity  or  direct  water  action,  exceeding  the  fan's  resistance  to  water 
penetration (see IP protection degree).

2. 

DEVICE CHARACTERISTICS

2.1INTERNATIONAL PROTECTION DEGREE IP

Determines  the  tightness  of  the  electrical  device  (fan  motor),  which  is  defied
 by two digits:

ź

 

first  characteristic  digit    - 

specifies  protection  of  the  device  against  access 

to dangerous parts as well as against penetration of solids

ź

 

second  characteristic  digit  – 

determines  the  resistance  of  the  engine 

to the water ingress, its waterproofness

 ENG

 

     

 

TECHNICAL DOCUMENTATON

Fan motors of the Farmer HCF serie

s

 have following IP:

 

5 - protection against access to hazardous parts by wire with a diameter of 1 mm 
or more and against dust in quantities which might impair the proper functioning 
of the equipment;
4 – protection against splashes of the water from any direction.

 

6- 

protection against access to hazardous parts by wire with a diameter of 1 mm 

or more and against dust (total dust tightness);
5 – protection against stream of the water (12.5 l/min) from any direction

2.2 

CONSTRUCTION AND PRINCIPLE OF OPERATION

Casing: 

made of expanded polypropylene (EPP). This material is characterized by 

low  density  (light  weighted)  and  high  chemical  and  physical  resistance. 
It has an excellent sound and thermal insulation properties. Moreover, material 
is environmentally friendly and "green", i.e. 100% recyclable.

Air  stators: 

made  of  polypropylene  PP.  It  is  possible  to  adjust  manually 

the  air  stators  to  achieve  the  needed  direction  of  the  air  flow.  There  are  also 
versions with confusor (increased airflow range) or with diffuser 360° (better 
mixing of supplied and room air).

Heating  coil: 

made  of  copper  and  aluminum. 

It  is  covered  by  LCE  coating. 

Supplied by distribution medium (heating or cooling), which circulates through 
the  coil  and  releases  or  extracts  heat  from  the  air.  The  coil  has  the  following 
technical parameters: the maximum temperature of the heating factor is 120°C; 
maximum  pressure  1.6  MPa;  headers  diameter  ¾”. 

Farmer  HCF  series  have 

a double row heat exchanger.

Axial 

blowing

  fan  IP54  (Farmer  HCF  IP54-3S): 

made  of  galvanized  steel. 

Fan has to ensure air flow through the exchanger. It has a single- and three phase 
motor  with  the  following  parameters:  protection  degree  IP54,  rate  current 
0.7-1.08 A (depending on the operating mode). Diameter of the fan is 450 mm. 

Axial 

blowing

 fan IP65 (Farmer HCF IP65): 

protective grid made of galvanized 

steel,  blades  and  casing  made  of    plastic.  Fan  has  to  ensure  air  flow  through 
the exchanger. It has a single-, three phase motor with the following parameters: 
protection degree IP65, rated current 2A. Diameter of the fan is 450 mm. 

Rotating  mounting  bracket  (optional  equipment): 

enables  the  device

to  be  installed  in  several  configurations  (depending  on  the  requirements) 
and the unit to be rotated in a horizontal plane. 

Farmer HCF IP54-3S

Farmer HCF I

P

65

2.

3

 

LCE COATING

The coating technology is based on immersion of the exchanger in the liquid LCE, 
which allows ptotection of the whole surface of the exchanger. The LCE coating 
is  waterproof  and  protects  the  heater  exchanger  from  corrosion,  mould 
and bacteria without compromising heat transfer efficiency. It is flexible enough 
not to be teared during thermal expansion of metal parts.

Periodic  maintenance  guarantees  the  resistance  of  the  LCE  coating 
to the following concentrations of chemical factors:

In  addition  the  above  LCE  COATING  demonstrates  high  resistance  to  fumes
 of the following: Lactic Acid, Oxalic Acid, Humic Acid, Saltwater and NOx.

Agent                                   

   Concentration

Hydrochloric Acid     

30%

Sulphuric Acid                         

 30%

Phosphoric Acid                       

  50%

Acetic Acid                         

 10%

Sodium Hydroxide                           

 10%

Ammonia in the air       

 30 ppm

Urea in the air         

30 ppm

Trichloroethylene                     

30 ppm

Toluene                                    

 25 ppm

Methylated Spirits                                      

 30 ppm

Mineral Turps          

 30 ppm

MEK         

25 ppm

Acetone                                           

25 ppm

Hydrogen Sulphide                           

 30 ppm

Summary of Contents for FARMER HCF IP54-3S

Page 1: ...Technical documentation AIR WATER HEATERS IN EPP CASING FARMER HCF SERIES MODELS FARMER HCF IP54 3S FARMER HCF IP65...

Page 2: ...ess itswaterproofness ENG TECHNICAL DOCUMENTATON FanmotorsoftheFarmerHCFserieshavefollowingIP 5 protection against access to hazardous parts by wire with a diameter of 1 mm ormoreandagainstdustinquant...

Page 3: ...2 19 1 22 1 25 2 28 3 31 3 34 3 1 39 1 25 1 11 0 97 0 84 70 50 0 5 10 15 20 18 2 15 1 12 1 9 15 6 23 12 7 15 7 18 7 21 7 24 6 1 58 1 31 1 05 0 79 0 54 0 5 10 15 20 66 2 62 2 58 3 54 5 50 7 36 9 40 3 4...

Page 4: ...isrecommendedtousefilteronthewatersupplypipe itisrecommendedtousethefollowingvalves ventvalveinthehighestplaceonthehydraulicinstallation cutoffvalveonthesupplyand returnpipesofthedevice installationha...

Page 5: ...5 control levels 80 105 135 170 230 V Voltage Frequency 230 V AC 50 60 Hz Maximum current output depending on model 1 2 A 3 A 5 A 7 A 14 A Protection thermal switch Weight depending on model 1 45 kg...

Page 6: ...s coefficient 6 5 m h Operating condition of actuator 0 60 C Running time motor 18 s Running time return spring 5 s Degree of protection IP 20 allows to connect a receiver with higher current consumpt...

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...arranty does not cover the parts of the device subject to normal maintenanceandthefollowingcases a mechanicaldamageoftheproduct b defectsanddamagesthrough improperstorageortransport improper or non co...

Page 17: ...Warranty card Reventon Group Sp z o o Ltd 556 Wyzwolenia Street 43 340 Kozy Poland...

Page 18: ...Reventon Group Sp z o o Ltd 556 Wyzwolenia Street 43 340 Kozy Poland www reventongroup eu...

Reviews: