INSTALLATION

3.1. 

GENERAL PRINCIPLES

The following figures show minimum

 

distances between the air curtain and the 

building partition

:

 

The width of the curtain should be greater or equal to the width of the door frame.  
When the entrance is wider than the unit, it is recommended to install two or more 
units in parallel. In this case, provide 10-40 mm gaps between the units 

3.2. 

ASSEBLY “STEP BY STEP”

The curtain can be assembled on wall or ceiling. If any components are not included 
in  the  kit,  you  should  buy  them    yourself  and  make  sure  they  are  suitable 
for this type of installation. 

a) 

wall mounting

unscrew  the  fixing  screws  to  remove  the  mounting  plate  from  the  back 

of the main body

-

install mounting plate on the wall

-

install the main body. Set the main body onto the upper end of the mounting 

plate and clamp it as shown

b) 

ceiling mounting (using mounting studs)

-

screw the mounting studs into four threaded holes (for min 20 mm)

-

install the unit using mounting studs to the ceiling

4. 

INSTALLATION INSTRUCTIONS 

4.1. 

CONNECTION OF THE DEVICE TO THE HYDAULIC SYSTEM

- pipes should be connected like on the figure below (water supply form the front, 
water return from the back)

RETURN

SUPPLY 

2.3 m

Summary of Contents for AC100WN1P

Page 1: ...AERIS 100WN 1P AERIS 150WN 1P AERIS 200WN 1P Technical documentation WATER HEATED AIR CURTAIN MODELS...

Page 2: ...ns and safety rules must be followed During the installation use service and periodical inspections all regulations and safety rules must be followed In case of unserviceable please plug out the devic...

Page 3: ...7 36 5 20 7 4 323 5 0 37 5 20 6 6 289 4 1 38 5 0 9 9 432 8 8 21 0 0 9 3 403 7 8 22 0 0 8 3 361 6 4 23 5 5 8 8 385 7 1 23 5 5 8 2 359 6 3 24 5 5 7 4 322 5 2 26 0 10 7 7 337 5 6 26 5 10 7 2 314 5 0 27 0...

Page 4: ...00WN 1P C kW l h kPa C C kW l h kPa C C kW l h kPa C 0 37 1 1638 53 5 36 5 0 34 0 1498 45 4 38 5 0 31 4 1386 39 4 40 5 5 34 8 1538 47 6 39 5 5 31 9 1406 40 5 41 0 5 29 5 1301 35 1 43 0 10 32 5 1436 42...

Page 5: ...should buy them yourself and make sure they are suitable forthistypeofinstallation a wallmounting unscrew the fixing screws to remove the mounting plate from the back ofthemainbody install mounting p...

Page 6: ...ngmediumthroughtheheatexchangermustbedependent on the fan operation e g using a thermostatic valve it is forbidden to keep theflowwithoutthefanmotorrunning ifthedeviceisnotusedforalongertimedisconnect...

Page 7: ...atedaircurtainAERISWN 1P 4 3 stagespeedcontrollerswiththermostatHC3S A workincontinuousmode B operationinthermostaticmode 5 Two wayvalvewithactuatorHC 6 Doorswitch 7 ProgrammablecontrollerHMI 8 Extern...

Page 8: ...pplier provides a repairment replacement orrefundforthedefectivedevicewithinaspecifiedtimelimit VII Warranty does not cover the parts of the device subject to normal maintenanceandthefollowingcases a...

Page 9: ...Warranty card...

Page 10: ......

Reviews: