10

7.) Bend the holding tabs you selected outward.

8.) Set FAN into place in the opening using holding tabs, now the tabs hold the fan 

in position in the ceiling opening.

holding tab 

holding tab 

holding tab 

WARNING:

 Disconnect the AC power before any work is done to any part of 

the circuit ReVent

®

 is connected to. If you do not understand this warning, 

seek the services of a qualified licensed electrician.

WARNING:

 Copper to copper only. Do 

not

 use aluminum wire.

WARNING:

 Follow all local electrical and safety codes, and NEC (National 

Electrical Codes).

CAUTION:

 If your house wires do not match these colors, determine what 

each house wire represents before connecting. You may need to consult a 

qualified licensed electrician to determine this safely.

9.) Disconnect FAN motor from electrical enclosure. Remove the electrical cover 

set screw and slide open the electrical enclosure.

10.) Connect wiring using the provided QUICK CONNECTS (U.S.A.) or WIRE 

NUTS (Canada).

OR

WIRE NUT

Qty:3

(Canada only)

2-WIRE QUICK

CONNECT

Qty:2

(U.S.A. only)

3-WIRE QUICK

CONNECT

Qty:1

(U.S.A. only)

remove set

 screw

unplug fan

 connector

slide

Summary of Contents for RVSH110

Page 1: ...and Save These Instructions Watch the installation video at reventfans com install Questions Call 1 877 543 8698 English or 1 800 615 5439 French models RVSH50 RVSH70 RVSH80 RVSH90 RVSH110 RVSH130 RV...

Page 2: ...g Care And Cleaning Installing The Control Using The Control Testing The Control Air Drafts In Wall Enclosure Frequently Asked Questions 3 Year Limited Warranty Specifications Duct Exhaust Diameter Vo...

Page 3: ...require modification of your current opening Some hand tools required Power tools may also be necessary RVSH130 RVSH150 Duct Exhaust Diameter Voltage Frequency Fan Watts Air Flow Fan Weight Sound Shie...

Page 4: ...tion only Qty 6 2 WIRE QUICK CONNECT Qty 2 U S A only 8 x 3 8 BRACKET SECURING SCREW used for new construction only Qty 3 WIRE NUT Qty 3 Canada only 3 WIRE QUICK CONNECT Qty 1 U S A only CONTROL Qty 1...

Page 5: ...nimal bends 6 Use 120 V 60 Hz for the electrical supply and properly ground the unit Follow all local safety and electrical codes 7 Do not use this fan with any solid state control device such as a di...

Page 6: ...LD should be installed after the finished ceiling is in place When installing in existing construction use the provided cutout TEMPLATE for the ceiling SHIELD edge should overlap finished ceiling Not...

Page 7: ...dels RVSH50 RVSH70 RVSH80 RVSH90 or RVSH110 4 in 10 16 cm round is recommended for best performance For models RVSH130 or RVSH150 6 in 15 24 cm round is recommended for best performance Ensure duct jo...

Page 8: ...spring together and pull down again to release the springs from the motor plate slots 3 Your existing fan may be attached in several ways Look for attachment screws in the ceiling and remove Your fan...

Page 9: ...il and remove the TEMPLATE Use a sheetrock jab saw to cut your fan opening in the ceiling SheetLock Easy Roomside Installation Watch the video REVENTFANS COM INSTALL WARNING Disconnect all AC Power Br...

Page 10: ...3 cm holding tab 5 Reattach DAMPER to FAN inside the ceiling damper should click into place securely ducting conduit DAMPER FAN 3 Attach DAMPER to ducting Tape DAMPER to ducting with duct tape Set th...

Page 11: ...um wire WARNING Follow all local electrical and safety codes and NEC National Electrical Codes CAUTION If your house wires do not match these colors determine what each house wire represents before co...

Page 12: ...ctrique 120 volts 60 Hz Maximum Fan Load 3 Amps Charge maximale du ventilateur 3 A Must Be Mounted Inside A Code Approved Electrical Outlet Box Doit tre mont dans une bo te de sortie lectrique r ponda...

Page 13: ...otch to vent DAMPER position Attach TRIM RING to FAN TRIM RING attaches to FAN body and clicks into place when secure sheetrock ceiling apply even pressure to each side of securing tab 11 Once connect...

Page 14: ...14 Attach the SHIELD by squeezing the mounting springs together and inserting the springs into the spring guides in the FAN 13 ceiling mounting springs FAN TRIM RING spring guide spring guide SHIELD...

Page 15: ...d be more familiar with as outlined in this section WARNING Disconnect all AC Power Breakers or Fuses before attempting to cut into your ceiling 1 Select a set of holding tabs depending on the thickne...

Page 16: ...raming joist framing joist FAN SHORT BRACKET can be cut down framing joist framing joist SHORT BRACKET LONG BRACKET conduit ROUNDHEAD WOOD SCREW Qty 6 use 2 per bracket 3 Attach FAN to ceiling joists...

Page 17: ...mine what each house wire represents before connecting You may need to consult a qualified licensed electrician to determine this safely 16 6 Disconnect FAN motor from electrical enclosure Remove the...

Page 18: ...imum Fan Load 3 Amps Charge maximale du ventilateur 3 A Must Be Mounted Inside A Code Approved Electrical Outlet Box Doit tre mont dans une bo te de sortie lectrique r pondant au code FAN VENTILATEUR...

Page 19: ...k the FAN in place final securing tabs sheetrock ceiling apply even pressure to each side of securing tab 10 Align TRIM RING notch to vent DAMPER position Attach TRIM RING to FAN TRIM RING attaches to...

Page 20: ...leaning the unit 1 Remove the SHIELD by squeezing the springs and pulling down 2 Remove dust and dirt from the FAN with a vacuum cleaner 3 Dampen cloth with dish detergent Wipe the FAN and dry with a...

Page 21: ...nently installed 120V AC powered fans only Use only 14 or 12 copper wire connections IMPORTANT Read each step carefully and perform in sequence The CONTROL will not work or will become damaged if wire...

Page 22: ...et am ricain et international en instance Electrical Input 120 volts 60Hz Entr e lectrique 120 volts 60 Hz Maximum Fan Load 3 Amps Charge maximale du ventilateur 3 A Must Be Mounted Inside A Code Appr...

Page 23: ...th the condensation humidity sensitivity set to average levels and the countdown timer set to 30 minutes To change the settings remove the TIMER AND SENSOR SETTINGS cover by taking off the face plate...

Page 24: ...he right an hour at a time Or if you feel the factory setting turns your fan on too quickly turn the dial to the left an hour at a time until the desired sensitivity level is reached Testing The Contr...

Page 25: ...in design seal any openings found apply caulking in these types of areas Frequently Asked Questions Fan Q How do I clean my FAN A It s important to clean the SHIELD cover from time to time Dust partic...

Page 26: ...u will need to test these wires with a voltage tester to determine which one is power and which one goes to the fan The black wire on the CONTROL connects to the wire that is tested to be the incoming...

Page 27: ...t to break the sensitivity and timer dials Q What happens if someone turns the FAN off before the room is fully dried A The CONTROL knows when your room needs to be dried If someone turns the CONTROL...

Page 28: ...t GTR s option shall be the purchaser s sole and exclusive remedy under this warranty GTR shall not be liable for incidental consequential or special damages arising out of or in connection with produ...

Reviews: