General Description
Build-in battery powered system for effective irrigation and wound
debridement of necrotic tissue. L.E.D light source integrated with
system provides
deep
cavity
lighting
.
Using the adequate pressure
improves growth of granulation tissue without disrupting underlying
normal tissues. Due to it’s mobility, low cost and variety of tips, it can
be widely used in Orthopaetics OR, Traumatology OR, hospital bed side,
outpatient clinics, long term care facilities.
F
ully
disposable
and
maintenance
-
free.
Pulse Lavage
Item NO. 2500 D-DPL Series
2500-D-DPL V2.0
This pack includes:
1 Hand piece
1 Small cone tip (ST01 Z) - Option
1 Coaxial Canal tip (CT02 Z) -Option
DC 10.5V / AA x 7 cells Alkaline Battery.
Tube Length 3 meter.
High speed flow rate up to 1000ml/M
Low speed flow rate 700ml/M
Pressure up to 15 PSI.
Specification
instruction manual
!
Do not re-sterilise
B
A
E
D
C
F
Instructions for Use
1. Peel open the pack and rem ove all of the items.
2. Retract Locki ng Ring by press ing up (A).
3. Attach the requi red tip to the handle of the gun and push on
unti l the connect ion is secur e (B).
(When usi ng the Int ra Medul lary Tip ensure the white cap is
rem oved befor e use).
4. Lock the requi red tip in place by depress ing the Locki ng Ring.
Retract the Locki ng Ring for tip rem oval (A).
5. Attach the irrigati on Line to the irrigati on sourc e (D).
6. Attach the suct ion Line to the suct ion carr ier sourc e (F) .
7. Remove the prot ect or from the Toggl e Trigger .
Dep res s the top for high speed fluid del ivery.
Dep res s the bott om of the Toggl e Trigger for low speed del ivery.
Center the Toggl e Trigger for no fluid del ivery.
NOTE:
8. The devi ce has a clamp on the irrigati on line which can be used
in the event of leakage of irrigati on fluid.
9. The devi ce has a clamp on the suct ion line which can be
adjus ted.
Press ing
the
top
posi tion
of
trigger
at High speed
to
start
while
the
first
time
use.
Sterile only if package is unopened and undamaged.
Store in a cool dry place.
Single use only! DO NOT Re-sterilize!
Warnings
International law restricts this device to sale by or on the order of a physician.
Caution
Rotate to remove battery cap and PULL OUT the Battery Pack until
disconnection from Pulse Lavage (E).
Battery Remove
G
Press the power button (G) to turn
ON
the light and press
again to turn it OFF if needed.
Turn ON/OFF L.E.D
Dongguan Kaiser Technology Co., Ltd.
No.81 Sanjiang Industrial District, Hengli Town,
Dongguan, Guangdong, CHINA
TEL: +86 -769 8189-3766
1 3 0 0 4 7 3 8 3 2
DO NOT
charge batteries.
The
empty
,
completely
flat
batteries
should
be
disposed
of
through specially
designated
collection
boxes
,
recycling
points or
electronics retailers
.
Please
dispose
of
the
device
in
accordance with EC
Directive
–
WEEE
(
Waste
Electrical
and
Electronic
Equipment
).
If
you have
any
questions
,
please
contact
the
local authorities responsible
for
waste
disposal
.
DO NOT
dispose battery in fire and keep away from liquid .
Disposal