Quartz Tube Removal and Cleaning (Every Six Months)

The UV lamps are housed in a quartz tube. If the quartz tube becomes dirty, its ability to transmit UV rays from the lamp will 

be diminished. The quartz tube(s) should be removed from the UV reactor every six (6) months and cleaned if necessary.

Note: If the DEL AOP is installed below water level, the bypass valves must all be CLOSED to prevent excess pool water from 

draining into the open unit when a quartz tube is removed. 

Quartz Tube

Drain Plug

Lamp Retainer

Retainer Screws

& Washers

Ceramic

Endcap

Sealing

O-ring

Quartz 

Tube

UV Reactor Subassembly

1.  Before continuing, allow adequate time for the quartz tubes to cool. Drain the water from the UV reactor by removing the 

drain plug. Replace the plug once water has stopped exiting the UV reactor. 

2. 

After removing the lamps, remove the top lamp retainer screws using the hex key included in the parts bag. Place the lamp 

retainer screws, washers and the lamp retainer aside in a safe place.

3.  Grasp the quartz tube from the top of the UV reactor. Pull to remove it from the UV reactor. 

4.  Remove the sealing O-ring from the top of the quartz tube. Set aside in a safe place. 

5.  Clean the quartz tube exterior with a mild solution of muriatic acid (available at all pool supply stores) and water in a ratio 

of four parts water to one part acid (4:1).  If lime or hard water calcium deposits are encountered, use a household tub 

and shower lime remover.

6. 

After cleaning the quartz tube, wash it off and wipe dry. Inspect the quartz tube for cracks. Replace if cracks are found. 

Make sure the inside of the quartz tube is dry before replacing the UV lamp(s). 

CAUTION

Follow the directions for use and handling of muriatic acid on the acid bottle label, being careful to 

protect your eyes, wear rubber gloves, and avoid breathing acid fumes. 

Note: DO NOT USE ABRASIVE CLEANERS as they can scratch the high quality quartz glass. Note: DAMAGE CAUSED BY 

BROKEN QUARTZ TUBES ARE NOT COVERED UNDER YOUR LIMITED WARRANTY. 