REV Ritter iComfort 84476-B Operating Instruction Download Page 4

Fig. 15: 

  Switch lamp 2 (channel 2)

   

Switch on = push ON

   

Switch off = push OFF

Blind switching (mode B)

Fig. 16:

   Open blind:  push ON

   

Stop blind: push ON again

   

Close blind:  push OFF

   

Stop blind: push OFF again

Timer for stairway light (mode C)

Fig. 17:

   Switch stairway light (channel 1)

   

Switch on = push ON

   

Switch off = automatically according to  

   

adjusted time (Fig. 9)

Fig. 18:

   Switch other lamp (channel 2)

   

Switch on = push ON

Technical data

•  Range: 100m (free field) 

•  Supply voltage: 230V~, 50Hz

•  Power: 500W

•  Inductive load: 1150VA (cos(phi)=0,8)

•  Fuse: T6,3A H 250V~

•  Frequency: 868MHz

•  Own power consumption: <0.5 Watt

•  Number of device groups: 2

•  Number of devices per device group: 10

•   Wiring: solid or standard rigid 1.5mm²

•   Pollution degree: IP20

CE Declaration of Conformity

REV Ritter hereby declares that the 84476-B 

model is in accordance with the underlying 

requirements and other relevant provisions 

of Directive 1999/5/EC. For the complete CE 

Declaration of Conformity please refer to 

 

www.rev.biz under the article in question. This 

product is a radio controlled system and should 

only be used as this. The buttons of the remote 

control could not be used permanently.

WEEE-reference of disposal

In accordance with European defaults used 

electrical and electronics devices may no more 

be given to the unsorted waste. The symbol of 

the waste bin on wheels refers to the necessity 

of separate collection. Please help with environ-

mental protection and see to it that this device is 

given to the for this purpose designated systems 

of waste sorting if you do not use it any longer.

DIRECTIVE 2012/19/EU of the EUROPEAN PARLIAMENT 

AND OF the COUNCIL of 4 July 2012 on waste electrical and  

electronic equipment (WEEE).

Warranty

During manufacturing this REV product is passed through 

several quality testing stations which are set up with newest 

technology. Should nevertheless a defect arise, REV offers a 

warranty to the following extent:

1. The duration of the warranty is 24 months after the date  

  of purchase.

2. The unit is either repaired or replaced by REV free of 

  charge or if it can be shown that it has become unusable  

  during the warranty period due to a manufacturing or  

  material defect.

3. The liability does not cover transport damages or 

 

  damaged incurred through defective installation. 

4. If REV repudiates the warranty claim and no objection is  

  made within 6 months, the right to repair becomes  

 time-barred.

5. In a warranty case the unit must be sent to the dealer or  

  REV together with the sales slip and a short description of  

  the defect. 

6. If there is no proof for a warranty liability being in place,  

  any repair carried out will be invoiced.

ENGLISH

868MHz

ENGLISH

REV Ritter GmbH • Frankenstr. 1-4 •  D-63776 Mömbris

Tel. +49 900 117 1070* •  E-Mail: [email protected] • www.rev.biz

*(0,36€/Min. aus dem deutschen Festnetz, Mobilfunk abweichend)

Connect according to mode

Separate switching of two lamps

Fig. 3:

  

N = neutral wire (blue)

   

L = phase (black)

  

^ = lamp 1

  

v = lamp 2

Blind control

Fig. 4:

  

N = neutral wire (blue)

   

L = phase (black)

  

^ = motor connection “open”

  

v = motor connection “close”

   

M = blind motor

Timer for stairway light

Fig. 3: 

 

N = neutral wire (blue)

   

L = phase (black)

  

^ = time controlled stairway light

  

v = other lamp

Choose mode

Important: 

Choose mode first, than start programming!

Subsequent change of mode deletes all programmings!

Fig. 5:

Separate switching of two lamps   

= mode A

Blind timer  

   

= mode B

Timer for stairway light  

   

= mode C

Teaching Fig. 7 / 8

•  All receivers must be programmed onto the button to  

  which it is meant to react.

1. The programming mode is activated for about  

  1 minute by pushing the „LEARN“ button of the product  

  for about 2 seconds. Thereby the red LED is flashing with  

  a frequency of 1Hz.

2. Now the device must be chosen on the remote control  

  and transmitted to the receiver by pushing the „ON“    

  button or operation the rocker switch.  

Group membership

 

Decide wheter the switch power socket is to react to a 

group call (device group 0). (See switch on the backside)

Only in combination with remote control type 84471-B.

Fig. 6:

ON  

Must react

OFF 

Must not react

Switching

Note: The figures show a key transmitter.

The programming of other transmitters is identical.

Separate switching of two lamps (mode A)

Fig. 14: 

  Switch lamp 1 (channel 1)

   

Switch on = push ON

   

Switch off = push OFF

Reviews: