• Find the wire hole at the bottom and pass the power wire through the hole. Connect the power with the
connection-wire column according to the Connection-wire Diagram.
• Fix the bottom on the selected position with the inflated screw.
• Fix the sensor at the bottom and tighten the screw. Switch on the power and then you can test it.
Figure 1
Figure 2
Figure 3
• It not only can install on the wall directly but also can install in the inner corner or outer corner with the help of the
widget (refer to photograph below).
Flat mounted
Inner corner mounted
Outer corner mounted
Note: you can cut the plastic cover whatever shape you want and make
different detection range. (refer to right figure).
CONNECTION-WIRE DIAGRAM
See the right figure
TEST
• Turn the TIME knob anti-clockwise on the minimum (10s). Turn the LUX knob
clockwise on the maximum (sun)
• Switch on the power; the sensor and its connected lamp will have no signal at
the beginning. After Warm-up 30sec, the sensor can start work .If the sensor
receives the induction signal, the lamp will turn on. While there is no another
induction signal any more, the load should stop working within 10sec±3sec
and the lamp would turn off.
• Turn LUX knob anti-clockwise on the minimum (3LUX). If the ambient light is more than 3LUX, the sensor would
not work and the lamp stop working too. If the ambient
light is less than 3LUX (darkness), the sensor
would work. Under no induction signal condition, the sensor
should stop working within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the sensor lamp could
not work!