Controlling the Device
35
one backward", the nozzle first moves forward for 20° to subsequently perform a backward
movement of 10°. As a result, near-mesh particles can be better removed because no resting
sample material obstructs the air flow.
With the function activated, the speed is fixed to 10 rpm. The current setting is displayed by one
of the following icons:
Open mesh function activated
Open mesh function deactivated
The open mesh function can be edited directly in manual mode. In programme mode the
parameter can only be changed when the edit mode has been activated via the menu item "Edit
program".
Use the rotary push button (
H4
) to navigate to the parameter "Open Mesh". The parameter is
highlighted in a darker background.
Press the rotary push button to activate the edit box. The edit box is highlighted in yellow.
Turn the rotary push button until the function is "On" or "Off" as desired.
Press the rotary push button to save the input. The edit box is no longer highlighted in
yellow.
Vac cleaner:
In manual mode, the external industrial vacuum cleaner can be switched on manually via the
menu item "Vac cleaner" and thus also used to clean the device. The vacuum cleaner function
is only available in manual mode.
Disconnect the suction pipe (
SR
) from the air outlet duct (
E
) or from the manual (
G
) or
automatic vacuum regulation.
Use the rotary push button (
H4
) to navigate to the parameter "Vac cleaner". The parameter
is highlighted in a darker background.
Press the
button (
H2
). The external industrial vacuum cleaner is switched on.
To switch off the external industrial vacuum cleaner, press the
button (
H1
).
7.4 Manual Mode
In manual mode, the following parameters can be edited directly:
Sieving time
Speed
Neg. pressure (only with automatic vacuum regulation)
Open mesh
Vac cleaner
Some settings can also be modified during the sieving process. A detailed description of the
parameter settings can be found in Chapter "
Save parameters:
The parameters set in manual mode can be assigned to an arbitrary programme memory
position or the
button (
H3
) via the "Save parameters" function.
In manual mode, navigate to the menu item "Save parameters" (
H6.1
).
Press the rotary push button (
H4
) to confirm the selection and to enter the submenu "SAVE
PARAMETERS".
Summary of Contents for AS 200 jet
Page 2: ...2 Copyright Copyright by Retsch GmbH Retsch Allee 1 5 42781 Haan Germany...
Page 5: ...Notes on the Manual 5...
Page 25: ...First Commissioning 25 Fig 10 Example of a label on the sieve lid...
Page 42: ...Controlling the Device 42 Fig 21 Submenu SERVICE H7 1...
Page 61: ...61...
Page 62: ...62...
Page 63: ...63...
Page 64: ...Copyright Copyright by Retsch GmbH Retsch Allee 1 5 42781 Haan Germany...